Comparison of the diagnostic accuracy of shear wave elastography with transient elastography in adult nonalcoholic fatty liver disease: a systematic review and network meta-analysis of diagnostic test accuracy

被引:0
|
作者
Yamaguchi, Ruri [1 ]
Oda, Tetsuro [2 ]
Nagashima, Kengo [3 ,4 ,5 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Invest Pathol, 2-1 Seiryomachi,Aobaku, Sendai 9808575, Japan
[2] Chugai Pharmaceut Co Ltd, Tokyo, Japan
[3] Keio Univ Hosp, Clin & Translat Res Ctr, Biostat Unit, Tokyo 1608582, Japan
[4] Nippon Med Sch, Grad Sch Med, Dept Bioregulat, Tokyo 1138602, Japan
[5] Natl Canc Ctr, Res Inst, Div Canc Therapeut, Tokyo, Japan
关键词
Network meta-analysis; Nonalcoholic fatty liver disease; Shear wave elastography; Transient elastography; STIFFNESS MEASUREMENT; FIBROSIS; PERFORMANCE; MANAGEMENT; DESIGN; BIOPSY;
D O I
10.1007/s00261-024-04546-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare the diagnostic test accuracy (DTA) of shear wave elastography (SWE) to that of transient elastography (TE) for liver fibrosis grade assessment in nonalcoholic fatty liver disease adults.MethodsMEDLINE, The Cochrane Library, and Web of Science were searched. Inclusion criteria were primary studies examining DTA of TE, point SWE (pSWE), two-dimensional SWE (2D-SWE), or magnetic resonance elastography (MRE) with liver biopsy. Network meta-analysis was conducted using a Bayesian bivariate mixed-effects model.ResultsFor fibrosis grade 2 or higher, 15 studies with 25 observations (16 observations for TE, 1 for MRE, 4 for pSWE and 2D-SWE; 2,066 patients) were included; the pooled sensitivity and specificity were 0.79 (95% credible interval (CrI) 0.70-0.86; 95% prediction interval (PI) 0.36-0.96) and 0.73 (95% CrI 0.62-0.82; 95% PI 0.23-0.96) for TE, 0.68 (95% CrI 0.48-0.83; 95% PI 0.23-0.94) and 0.75 (95% CrI 0.53-0.88; 95% PI 0.24-0.97) for pSWE, 0.85 (95% CrI 0.70-0.93; 95% PI 0.40-0.98) and 0.72 (95% CrI 0.49-0.86; 95% PI 0.20-0.96) for 2D-SWE, respectively. The proportion of studies classified as unclear in QUADAS-2 was high, and the results were heterogeneous.Conclusion2D-SWE could be recommended as TE is for liver fibrosis assessment.The protocol of this systematic review and network meta-analysis has been registered in PROSPERO (CRD42022327249). All included primary papers have already been published and the information and data can be used freely.Conclusion2D-SWE could be recommended as TE is for liver fibrosis assessment.The protocol of this systematic review and network meta-analysis has been registered in PROSPERO (CRD42022327249). All included primary papers have already been published and the information and data can be used freely.
引用
下载
收藏
页码:734 / 746
页数:13
相关论文
共 50 条
  • [11] Transient elastography: a meta-analysis of diagnostic accuracy in evaluation of portal hypertension in chronic liver disease
    Shi, Ke-Qing
    Fan, Yu-Chen
    Pan, Zhen-Zhen
    Lin, Xian-Feng
    Liu, Wen-Yue
    Chen, Yong-Ping
    Zheng, Ming-Hua
    LIVER INTERNATIONAL, 2013, 33 (01) : 62 - 71
  • [12] A meta-analysis on the diagnostic performance of magnetic resonance imaging and transient elastography in nonalcoholic fatty liver disease
    Gu, Qing
    Cen, Li
    Lai, Jiawei
    Zhang, Zhongchen
    Pan, Jiaqi
    Zhao, Feng
    Yu, Chaohui
    Li, Youming
    Chen, Chunxiao
    Chen, Weixing
    Shen, Zhe
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2021, 51 (02)
  • [13] Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis
    Schambeck, Joao Paulo L.
    Forte, Gabriele C.
    Goncalves, Luana M.
    Stuker, Guilherme
    Kotlinski, Joao Bruno F.
    Tramontin, Giacomo
    Altmayer, Stephan
    Watte, Guilherme
    Hochhegger, Bruno
    PLOS ONE, 2023, 18 (02):
  • [14] ELASTOGRAPHY FOR THE DIAGNOSIS OF SEVERITY OF FIBROSIS IN CHRONIC LIVER DISEASE: A DIAGNOSTIC TEST ACCURACY META-ANALYSIS
    Tsochatzis, E.
    Gurusamy, K.
    Ntaoula, S.
    Garcovich, M.
    Davidson, B.
    Burroughs, A.
    GUT, 2010, 59 : A15 - A15
  • [15] Diagnostic accuracy of Shear Wave Elastography for the assessment of liver stiffness in pediatric patients with fatty liver disease
    Garcovich, Matteo
    Veraldi, Silvio
    Di Stasio, Enrico
    Zocco, Maria Assunta
    Pompili, Maurizio
    Gasbarrini, Antonio
    Nobili, Valerio
    HEPATOLOGY, 2016, 64 : 274A - 274A
  • [16] Diagnostic Accuracy of 2D-Shear Wave Elastography for Liver Fibrosis Severity: A Meta-Analysis
    Jiang, Tian'an
    Tian, Guo
    Zhao, Qiyu
    Kong, Dexing
    Cheng, Chao
    Zhong, Liyun
    Li, Lanjuan
    PLOS ONE, 2016, 11 (06):
  • [17] Diagnostic Accuracy of 2-Dimensional Shear Wave Elastography for the Staging of Liver Fibrosis: A Meta-analysis
    Zhang, Wei
    Zhu, Ya
    Zhang, Cuncheng
    Ran, Haitao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (03) : 733 - 740
  • [18] Diagnostic Accuracy of Real-Time Shear Wave Elastography for Staging of Liver Fibrosis: A Meta-Analysis
    Li, Changtian
    Zhang, Changsheng
    Li, Junlai
    Huo, Huiping
    Song, Danfei
    MEDICAL SCIENCE MONITOR, 2016, 22 : 1349 - 1359
  • [19] Diagnostic Accuracy of 2-Dimensional Shear Wave Elastography for the Staging of Liver Fibrosis: A Meta-analysis
    Zhang, Wei
    Zhu, Ya
    Zhang, Cuncheng
    Ran, Haitao
    Journal of Ultrasound in Medicine, 2019, 38 (03): : 733 - 740
  • [20] Systematic review with meta-analysis: the diagnostic accuracy of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B
    Li, Y.
    Huang, Y. -S.
    Wang, Z. -Z.
    Yang, Z. -R.
    Sun, F.
    Zhan, S. -Y.
    Liu, X. -E.
    Zhuang, H.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2016, 43 (04) : 458 - 469