Comparison of the diagnostic accuracy of shear wave elastography with transient elastography in adult nonalcoholic fatty liver disease: a systematic review and network meta-analysis of diagnostic test accuracy

被引:0
|
作者
Yamaguchi, Ruri [1 ]
Oda, Tetsuro [2 ]
Nagashima, Kengo [3 ,4 ,5 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Invest Pathol, 2-1 Seiryomachi,Aobaku, Sendai 9808575, Japan
[2] Chugai Pharmaceut Co Ltd, Tokyo, Japan
[3] Keio Univ Hosp, Clin & Translat Res Ctr, Biostat Unit, Tokyo 1608582, Japan
[4] Nippon Med Sch, Grad Sch Med, Dept Bioregulat, Tokyo 1138602, Japan
[5] Natl Canc Ctr, Res Inst, Div Canc Therapeut, Tokyo, Japan
关键词
Network meta-analysis; Nonalcoholic fatty liver disease; Shear wave elastography; Transient elastography; STIFFNESS MEASUREMENT; FIBROSIS; PERFORMANCE; MANAGEMENT; DESIGN; BIOPSY;
D O I
10.1007/s00261-024-04546-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare the diagnostic test accuracy (DTA) of shear wave elastography (SWE) to that of transient elastography (TE) for liver fibrosis grade assessment in nonalcoholic fatty liver disease adults.MethodsMEDLINE, The Cochrane Library, and Web of Science were searched. Inclusion criteria were primary studies examining DTA of TE, point SWE (pSWE), two-dimensional SWE (2D-SWE), or magnetic resonance elastography (MRE) with liver biopsy. Network meta-analysis was conducted using a Bayesian bivariate mixed-effects model.ResultsFor fibrosis grade 2 or higher, 15 studies with 25 observations (16 observations for TE, 1 for MRE, 4 for pSWE and 2D-SWE; 2,066 patients) were included; the pooled sensitivity and specificity were 0.79 (95% credible interval (CrI) 0.70-0.86; 95% prediction interval (PI) 0.36-0.96) and 0.73 (95% CrI 0.62-0.82; 95% PI 0.23-0.96) for TE, 0.68 (95% CrI 0.48-0.83; 95% PI 0.23-0.94) and 0.75 (95% CrI 0.53-0.88; 95% PI 0.24-0.97) for pSWE, 0.85 (95% CrI 0.70-0.93; 95% PI 0.40-0.98) and 0.72 (95% CrI 0.49-0.86; 95% PI 0.20-0.96) for 2D-SWE, respectively. The proportion of studies classified as unclear in QUADAS-2 was high, and the results were heterogeneous.Conclusion2D-SWE could be recommended as TE is for liver fibrosis assessment.The protocol of this systematic review and network meta-analysis has been registered in PROSPERO (CRD42022327249). All included primary papers have already been published and the information and data can be used freely.Conclusion2D-SWE could be recommended as TE is for liver fibrosis assessment.The protocol of this systematic review and network meta-analysis has been registered in PROSPERO (CRD42022327249). All included primary papers have already been published and the information and data can be used freely.
引用
下载
收藏
页码:734 / 746
页数:13
相关论文
共 50 条
  • [1] Diagnostic accuracy of two-dimensional shear wave elastography and transient elastography in nonalcoholic fatty liver disease
    Sharpton, Suzanne R.
    Tamaki, Nobuharu
    Bettencourt, Ricki
    Madamba, Egbert
    Jung, Jinho
    Liu, Amy
    Behling, Cynthia
    Valasek, Mark A.
    Loomba, Rohit
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2021, 14
  • [2] Diagnostic Accuracy of Point of Care Liver Elastography for Nonalcoholic Fatty Liver Disease: A Systematic Review and Meta-Analysis
    Das, Taranika Sarkar
    Abdallah, Mohamed
    Bilal, Mohammad
    El Zoghbi, Maysa
    Shaukat, Aasma
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2023, 118 (10): : S1197 - S1198
  • [3] Diagnostic Accuracy of Elastography and Liver Disease: A Meta-Analysis
    Malik, Preeti
    Pillai, Shreejith
    Agarwal, Kriti
    Abdelwahed, Salwa
    Bhandari, Renu
    Singh, Abhishek
    Chidharla, Anusha
    Patel, Kajal
    Singh, Priyanka
    Manaktala, Pritika
    Rabbani, Rizwan
    Koritala, Thoyaja
    Gupta, Sachin
    GASTROENTEROLOGY RESEARCH, 2022, 15 (05) : 232 - 239
  • [4] Diagnostic Accuracy of Transient Elastography and Two-Dimensional Shear Wave Elastography for Staging Liver Fibrosis in Children or Adolescents: A Systematic Review and Meta-Analysis
    Gong, Xiuru
    Zhu, Tingting
    Peng, Xiaolin
    Xing, Dongwei
    Zhang, Minguang
    CURRENT MEDICAL IMAGING, 2023, 19 (11) : 1258 - 1272
  • [5] Diagnostic accuracy of point shear wave elastography and transient elastography for staging hepatic fibrosis in patients with non-alcoholic fatty liver disease: a meta-analysis
    Jiang, Weixi
    Huang, Sirun
    Teng, Hua
    Wang, Peipei
    Wu, Meng
    Zhou, Xia
    Ran, Haitao
    BMJ OPEN, 2018, 8 (08):
  • [6] Systematic review with meta-analysis: diagnostic accuracy of transient elastography for staging of fibrosis in people with alcoholic liver disease
    Pavlov, C. S.
    Casazza, G.
    Nikolova, D.
    Tsochatzis, E.
    Gluud, C.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2016, 43 (05) : 575 - 585
  • [7] Diagnostic accuracy of shear wave elastography for endometrial cancer: A meta-analysis
    Bian, Jinyi
    Li, Jingnan
    Liu, Yangcheng
    MEDICINE, 2023, 102 (04) : E32700
  • [8] DIAGNOSTIC ACCURACY OF THE SHEAR WAVE ELASTOGRAPHY FOR THE IDENTIFICATION OF PROSTATE CANCER: A DIAGNOSTIC META-ANALYSIS
    Tu, Xiang
    Yang, Lu
    Wei, Qiang
    JOURNAL OF UROLOGY, 2017, 197 (04): : E98 - E98
  • [9] The diagnostic accuracy of vibration controlled transient elastography for cirrhosis in subjects with nonalcoholic fatty liver disease
    Siddiqui, M. S.
    Vuppulanchi, R.
    Van Natta, M.
    Brandman, D.
    Tonascia, J. T.
    Chalasani, N.
    Middleton, M. S.
    Sanyal, A. J.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S426 - S426
  • [10] Diagnostic Accuracy of Shear-Wave Elastography for Breast Lesion Characterization in Women: A Systematic Review and Meta-Analysis
    Pillai, Aishwarya
    Voruganti, Teja
    Barr, Richard
    Langdon, Jonathan