Dual-Parameter Measurement System for Dynamic and Static Pressure Based on a Fiber-Optic FPE Sensor

被引:3
|
作者
Cheung, Yang [1 ]
Jing, Zhenguo [1 ]
Ling, Zebin [2 ]
Zhou, Da-Peng [1 ]
Peng, Wei [1 ]
机构
[1] Dalian Univ Technol, Sch Phys, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Sch Optoelect Engn & Instrumentat Sci, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
Acoustic pressure; distributed feedback (DFB) laser; dual-parameter measurement; Fabry(!-!)Perot etalon (FPE) sensor; static pressure; PEROT ACOUSTIC SENSOR; TEMPERATURE; MICROPHONE;
D O I
10.1109/JSEN.2024.3384475
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes a sensing system that utilizes a fiber-optic Fabry-Perot etalon (FPE) interferometric sensor and a narrowband distributed feedback (DFB) laser for dual-parametric measurements of dynamic and static pressure. As the pressure signal passes through the central opening of the rigid FPE sensor, the pressure causes a change in the refractive index of the air in the sensor cavity, which in turn causes a change in the optical path difference (OPD) rather than the traditional pressure-induced mechanical displacement. Even though the wavelength tuning range of DFB lasers is only a few hundred pm, the appropriate cavity length of the FPE sensor ensures that it can always cover a complete spectral period. Ensuring that the wavelength of the DFB laser is fixed within the linear region of the sensor spectrum will lead to time-varying ac intensity signals caused by acoustic waves. The cross correlation algorithm is a high-precision method for absolute cavity length interrogation that can be used to obtain the OPD of the sensor and determine the static pressure parameters. The experimental results demonstrate a 53-dB signal-to-noise ratio (SNR) at 1-kHz acoustic pressure, along with an acoustic sensitivity of 4.025 V/Pa and a pressure sensitivity of 15.8 nm/kPa for static pressure ranging from 0 to 70 kPa. Additionally, the full-phase demodulation advantage of the cross correlation algorithm ensures an OPD resolution within 2.5 nm, even when the wavelength tuning range of the narrowband DFB laser used is less than 1 nm. The proposed dual-parameter measurement scheme relies solely on a single FPE sensor, simplifying the system structure and reducing costs, and offers a competitive solution for dual-parameter measurement of acoustic and static pressure in aerospace.
引用
收藏
页码:17701 / 17708
页数:8
相关论文
共 50 条
  • [31] Dual-Parameter Sensor for Temperature and Strain Measurement Based on Antiresonance Effect and Few-Mode Fiber
    Jiang, Shaocui
    Yang, Peng
    Wang, Zenghui
    Zhang, Yujuan
    Bao, Wangge
    Peng, Baojin
    PHOTONICS, 2023, 10 (06)
  • [32] Temperature desensitization of a fiber-optic pressure sensor by simultaneous measurement of pressure and temperature
    Universite du Quebec a Hull, Hull, Canada
    Appl Opt, 18 (3897-3901):
  • [33] Temperature desensitization of a fiber-optic pressure sensor by simultaneous measurement of pressure and temperature
    Bock, WJ
    Urbanczyk, W
    APPLIED OPTICS, 1998, 37 (18): : 3897 - 3901
  • [34] Fiber-optic sensor system for heat-flux measurement
    Shen, YH
    He, JL
    Zhao, WZ
    Sun, T
    Grattan, KTV
    Pritchard, WDN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (04): : 1006 - 1012
  • [35] Fiber-Optic Interferometric Sensor for Dynamic Impact Measurement of Transport Trucks
    Stolarik, Martin
    Nedoma, Jan
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2019, 42 : 34 - 46
  • [36] Miniature fiber-optic sensor for simultaneous measurement of pressure and refractive index
    Pevec, Simon
    Donlagic, Denis
    OPTICS LETTERS, 2014, 39 (21) : 6221 - 6224
  • [37] Study on dual-parameter fiber sensor based on LPFG cascaded with FBG structure
    Zhang, Wen
    Liu, Xiaolong
    He, Wei
    Zhu, Lianqing
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2017, 38 (08): : 2047 - 2054
  • [38] A Dual-Parameter Optical Fiber SPR Sensor for Simultaneous Measurement of Glucose and Cholesterol Concentrations
    Wang, Xingyu
    Sun, Xiaoyan
    Hu, Youwang
    Zhang, Limu
    Zeng, Li
    Liu, Qishi
    Duan, Ji'an
    IEEE SENSORS JOURNAL, 2022, 22 (21) : 20413 - 20420
  • [39] Optic fiber-based dynamic pressure sensor for WIM system
    Yuan, SF
    Ansari, F
    Liu, XH
    Zhao, Y
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 120 (01) : 53 - 58
  • [40] Multimode interference based fiber-optic sensor for temperature measurement
    Noor, S. F. S. M.
    Harun, S. W.
    Ahmad, H.
    Muhammad, A. R.
    NEWTON RESEARCHER LINKS WORKSHOP: 2018 BIO-PHOTONICS FOR MEDICAL TECHNOLOGIES, 2019, 1151