Training for ultrasound-guided implantation of central venous catheters eliminates venolysis in pediatric patients

被引:0
|
作者
Finazzi, Paolo [1 ]
Perez, Carmen Rodriguez [2 ]
Risso, Francesco Maria [2 ]
Giannini, Alberto Michele [1 ]
机构
[1] ASST Spedali Civili, Childrens Hosp, Pediat Anesthesia & Intens Care Unit, Piazzale Spedali Civili 1, I-25123 Brescia, Italy
[2] ASST Spedali Civili, Childrens Hosp, Neonatal Intens Care Unit, Brescia, Italy
来源
关键词
Central venous catheterization; neonates; infants; children; ultrasound; bundle; training; venolysis; BRACHIOCEPHALIC VEIN; VASCULAR ACCESS; INSERTION; CHILDREN; ASSOCIATION; PATENCY; DEVICES; PICC;
D O I
10.1177/11297298241278775
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: In the pediatric setting, the procurement of vascular access can be particularly difficult. Surgical venolysis was the first technique described but, in recent years, the literature has shown that ultrasound-guided implantation has fewer complications. The principal aim of this paper is to state how after a structured training to place ultrasound-guided central lines, venolysis was definitively abandoned in our hospital. We also analyzed the impact of training on the duration of procedures. Finally, the number of procedures performed per operator to maintain the quality standard achieved. Method: In this observational retrospective study, we analyzed data from 2013 to 2020 of 1497 pediatric and neonatal central venous access placements in a single center during a training path. Results: Venolysis performed by the pediatric surgeons was used in 11% of total placements, the most in the smallest patients (76.1%, <1 year of age). With the implementation of training, this invasive technique became obsolete to the point where it was no longer practiced (24.6% of vascular placement in 2013 to 0% in 2020). In the placement performed by the pediatric anesthesiologists, time progressively decreased from 51.5 min in 2013 to 29.4 min in 2022. From the analysis of the number of procedures performed by pediatric anesthesiologists, the first consultant involved performed averaging 48 procedures per year, while the other consultants had an overall average of 16.7-25 placements per year. Conclusion: Echo-guided vascular cannulation was found to be safe, reliable, and reproducible in pediatric patients and neonates and permits to deletion definitively venolysis. Well-structured training is essential and should be standardized in the future.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Education in the placement of ultrasound-guided peripheral venous catheters: a systematic review
    Rasmus Jørgensen
    Christian B. Laursen
    Lars Konge
    Pia Iben Pietersen
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 29
  • [32] Predicting the optimal depth of ultrasound-guided right internal jugular vein central venous catheters in neonates
    Montes-Tapia, Fernando
    Hernandez-Trejo, Karla
    Garcia-Rodriguez, Fernando
    Jaime-Reyes, Julio
    Trevino-Garza, Consuelo
    Cardenas-del Castillo, Barbara
    Rodriguez-Balderrama, Isaias
    de la O-Cavazos, Manuel
    JOURNAL OF PEDIATRIC SURGERY, 2020, 55 (09) : 1920 - 1924
  • [33] Reducing peripherally inserted central catheters and midline catheters by training nurses in ultrasound-guided peripheral intravenous catheter placement
    Galen, Benjamin
    Baron, Sarah
    Young, Sandra
    Hall, Alleyne
    Berger-Spivack, Linda
    Southern, William
    BMJ QUALITY & SAFETY, 2020, 29 (03) : 245 - 249
  • [34] Predicting the Optimal Depth of Ultrasound-Guided Right Internal Jugular Vein Central Venous Catheters in Neonates
    Moon, Suk Bae
    JOURNAL OF PEDIATRIC SURGERY, 2021, 56 (03) : 638 - 638
  • [35] No association between ultrasound-guided insertion of central venous catheters and bloodstream infection: a prospective observational study
    Cartier, V.
    Haenny, A.
    Inan, C.
    Walder, B.
    Zingg, W.
    JOURNAL OF HOSPITAL INFECTION, 2014, 87 (02) : 103 - 108
  • [36] Ultrasound-Guided Peripheral Intravenous Catheters to Reduce Central Venous Catheter Use on the Inpatient Medical Ward
    Galen, Benjamin T.
    Southern, William N.
    QUALITY MANAGEMENT IN HEALTH CARE, 2018, 27 (01) : 30 - 32
  • [37] No association between ultrasound-guided insertion of central venous catheters and bloodstream infection: a prospective observational study
    Zingg, W.
    Cartier, V.
    Walder, B.
    JOURNAL OF HOSPITAL INFECTION, 2015, 90 (01) : 82 - 82
  • [38] Ultrasound-guided central venous catheterization in the prone position
    Chen, G. -Y.
    Cheng, K. -I.
    Hsu, H. -T.
    Lu, Y. -M.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 (02) : 337 - 338
  • [39] Ultrasound-guided central venous cannulation in infants and children
    Åsheim, P
    Mostad, U
    Aadahl, P
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (04) : 390 - 392
  • [40] Future directions for ultrasound-guided central venous access
    O'Leary, Ronan
    Bodenham, Andrew
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (05) : 327 - 328