Enhancing thermal efficiency in flat plate solar collectors through internal barrier optimization

被引:0
|
作者
Dhairiyasamy, Ratchagaraja [1 ,2 ]
Rajendran, Silambarasan [3 ,4 ]
Khan, Sher Afghan [5 ]
Alahmadi, Ahmad Aziz [6 ]
Alwetaishi, Mamdooh [7 ]
Agbulut, Umit [8 ,9 ,10 ]
机构
[1] Shinawatra Univ, Fac Engn & Technol, Bangkok, Thailand
[2] Saveetha Univ, Saveetha Sch Engn, Saveetha Inst Med & Tech Sci, Dept Elect & Commun Engn, Chennai, Tamilnadu, India
[3] Annapoorna Engn Coll, Dept Mech Engn, Salem, Tamil Nadu, India
[4] Chitkara Univ, Chitkara Univ Inst Engn & Technol, Ctr Res Impact & Outcome, Rajpura 140417, Punjab, India
[5] Int Islamic Univ, Dept Mech & Aerosp Engn, Kualalumpur, Malaysia
[6] Taif Univ, Coll Engn, Dept Elect Engn, Taif 21944, Saudi Arabia
[7] Taif Univ, Coll Engn, Dept Civil Engn, Taif 21944, Saudi Arabia
[8] Yildiz Tech Univ, Dept Mech Engn, Fac Mech Engn, TR-34349 Istanbul, Turkiye
[9] Western Caspian Univ, Dept Tech Sci, Baku, Azerbaijan
[10] Calif State Univ Los Angeles, State Univ Dr 5151, Los Angeles, CA 90032 USA
关键词
Energy efficiency; Convective heat transfer; Flat plate collectors; Thermal performance; Solar energy; SYSTEM; FLOW;
D O I
10.1016/j.tsep.2024.102856
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the impact of introducing horizontal barriers within the internal cavity of flat plate solar collectors on their thermal efficiency. The primary objective is to enhance thermal performance by reducing convective heat loss. An experimental test bench was constructed to evaluate five solar collectors under controlled conditions. One collector was unmodified as a reference, while the other four had 1 to 4 horizontal barriers inserted between the absorber plate and glass cover. Each collector's efficiency was assessed by measuring inlet and outlet water temperatures, incident solar radiation, ambient temperature, and water flow rate. Efficiency versus heat loss parameter curves were generated, and correction factors were applied to account for material and sensor differences. The collector with four barriers demonstrated the highest overall thermal efficiency, achieving an efficiency improvement of up to 12 % compared to the reference collector. Specifically, the efficiency of the reference collector was around 70 %, while the collector with four barriers reached an efficiency of approximately 82 %. Introducing two barriers resulted in a 9 % increase in efficiency, bringing it to about 79 %. Conversely, the collector with three barriers showed a slight decrease in efficiency to 68 %. The barriers effectively reduced internal convective heat loss, enhancing the collector's ability to harness incident solar radiation. Inserting horizontal barriers within the internal cavity of flat plate solar collectors significantly improves thermal efficiency by reducing convective heat loss. The optimal configuration, based on this study, involves using four barriers. This method presents a straightforward yet effective approach to enhancing solar collector performance. Future research should focus on refining barrier design and placement for different collector sizes and geometries, potentially supporting broader adoption of solar thermal energy systems and contributing to sustainable energy solutions.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] EFFECT OF CONTACT SPACING ON EFFICIENCY OF FLAT-PLATE SOLAR COLLECTORS
    CRHA, S
    SCHNEIDER, GE
    JOURNAL OF SPACECRAFT AND ROCKETS, 1985, 22 (06) : 585 - 591
  • [22] Experimental evaluation of the influence of infiltration on the efficiency of solar flat plate collectors
    Paiva, Elisiane S. A.
    Diniz, Antonia Sonia A. C.
    Faria, Lucas P. P.
    Silverio, Thiago A.
    Barreto, Rafael O.
    Maia, Cristiana B.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2015, 2015, : 1005 - 1012
  • [23] A review on solar flat plate collectors
    Jebaraj, S.
    Al-Qahtani, Ali Mubarak
    INTERNATIONAL JOURNAL OF GLOBAL ENERGY ISSUES, 2021, 43 (2-3) : 114 - 134
  • [24] Characterization of solar flat plate collectors
    Cruz-Peragon, F.
    Palomar, J. M.
    Casanova, P. J.
    Dorado, M. P.
    Manzano-Agugliaro, F.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (03): : 1709 - 1720
  • [25] ON THE CLIMATIC OPTIMIZATION OF THE TILT AND AZIMUTH OF FLAT-PLATE SOLAR COLLECTORS
    WILLMOTT, CJ
    SOLAR ENERGY, 1982, 28 (03) : 205 - 216
  • [26] Dimension and insulation thickness optimization of circular flat plate solar collectors
    Argunhan, Zeki
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2011, 27 (02): : 287 - 294
  • [27] Thermal load based adaptive tracking for flat plate solar collectors
    Neagoe, Mircea
    Visa, Ion
    Burduhos, Bogdan G.
    Moldovan, Macedon D.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 : 1401 - 1411
  • [28] Entransy analysis on the thermal performance of flat plate solar air collectors
    Jie Deng
    Xudong Yang
    Yupeng Xu
    Ming Yang
    Building Simulation, 2017, 10 : 193 - 202
  • [29] Experimental calculation of the mean temperature of flat plate thermal solar collectors
    Seco-Nicolas, Manuel
    Alarcon Garcia, Mariano
    Pedro Luna-Abad, Juan
    RESULTS IN ENGINEERING, 2020, 5
  • [30] Thermal performance of gas-filled flat plate solar collectors
    Vestlund, Johan
    Ronnelid, Mats
    Dalenback, Jan-Olof
    SOLAR ENERGY, 2009, 83 (06) : 896 - 904