Enhancing thermal efficiency in flat plate solar collectors through internal barrier optimization

被引:0
|
作者
Dhairiyasamy, Ratchagaraja [1 ,2 ]
Rajendran, Silambarasan [3 ,4 ]
Khan, Sher Afghan [5 ]
Alahmadi, Ahmad Aziz [6 ]
Alwetaishi, Mamdooh [7 ]
Agbulut, Umit [8 ,9 ,10 ]
机构
[1] Shinawatra Univ, Fac Engn & Technol, Bangkok, Thailand
[2] Saveetha Univ, Saveetha Sch Engn, Saveetha Inst Med & Tech Sci, Dept Elect & Commun Engn, Chennai, Tamilnadu, India
[3] Annapoorna Engn Coll, Dept Mech Engn, Salem, Tamil Nadu, India
[4] Chitkara Univ, Chitkara Univ Inst Engn & Technol, Ctr Res Impact & Outcome, Rajpura 140417, Punjab, India
[5] Int Islamic Univ, Dept Mech & Aerosp Engn, Kualalumpur, Malaysia
[6] Taif Univ, Coll Engn, Dept Elect Engn, Taif 21944, Saudi Arabia
[7] Taif Univ, Coll Engn, Dept Civil Engn, Taif 21944, Saudi Arabia
[8] Yildiz Tech Univ, Dept Mech Engn, Fac Mech Engn, TR-34349 Istanbul, Turkiye
[9] Western Caspian Univ, Dept Tech Sci, Baku, Azerbaijan
[10] Calif State Univ Los Angeles, State Univ Dr 5151, Los Angeles, CA 90032 USA
关键词
Energy efficiency; Convective heat transfer; Flat plate collectors; Thermal performance; Solar energy; SYSTEM; FLOW;
D O I
10.1016/j.tsep.2024.102856
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the impact of introducing horizontal barriers within the internal cavity of flat plate solar collectors on their thermal efficiency. The primary objective is to enhance thermal performance by reducing convective heat loss. An experimental test bench was constructed to evaluate five solar collectors under controlled conditions. One collector was unmodified as a reference, while the other four had 1 to 4 horizontal barriers inserted between the absorber plate and glass cover. Each collector's efficiency was assessed by measuring inlet and outlet water temperatures, incident solar radiation, ambient temperature, and water flow rate. Efficiency versus heat loss parameter curves were generated, and correction factors were applied to account for material and sensor differences. The collector with four barriers demonstrated the highest overall thermal efficiency, achieving an efficiency improvement of up to 12 % compared to the reference collector. Specifically, the efficiency of the reference collector was around 70 %, while the collector with four barriers reached an efficiency of approximately 82 %. Introducing two barriers resulted in a 9 % increase in efficiency, bringing it to about 79 %. Conversely, the collector with three barriers showed a slight decrease in efficiency to 68 %. The barriers effectively reduced internal convective heat loss, enhancing the collector's ability to harness incident solar radiation. Inserting horizontal barriers within the internal cavity of flat plate solar collectors significantly improves thermal efficiency by reducing convective heat loss. The optimal configuration, based on this study, involves using four barriers. This method presents a straightforward yet effective approach to enhancing solar collector performance. Future research should focus on refining barrier design and placement for different collector sizes and geometries, potentially supporting broader adoption of solar thermal energy systems and contributing to sustainable energy solutions.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] EFFICIENCY OF SOLAR FLAT-PLATE COLLECTORS
    MARSCHALL, E
    ADAMS, G
    SOLAR ENERGY, 1978, 20 (05) : 413 - 414
  • [2] Exergetic optimization of flat plate solar collectors
    Farahat, S.
    Sarhaddi, F.
    Ajam, H.
    RENEWABLE ENERGY, 2009, 34 (04) : 1169 - 1174
  • [3] Thermodynamic optimization of flat plate solar collectors
    Maha, Benhamad
    Ali, Snoussi
    Ammar, Ben Brahim
    2014 5TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2014,
  • [4] Study on thermal efficiency of large-scale flat plate solar collectors
    Wang D.
    Ren Y.
    Liu Y.
    Liu J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (07): : 214 - 219
  • [5] Experimental study on cylindrical and flat plate solar collectors' thermal efficiency comparison
    Ahmadlouydarab, Majid
    Anari, Tahereh Dana
    Akbarzadeh, Alireza
    RENEWABLE ENERGY, 2022, 190 : 848 - 864
  • [6] Exergetic optimization research of flat plate solar collectors
    Ge, Zhong
    Wang, Huitao
    Wang, Hua
    Zhang, Songyuan
    Guan, Xin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2015, 36 (07): : 1684 - 1689
  • [7] Performance of evacuated flat plate solar thermal collectors
    Moss, Roger
    Shire, Stan
    Henshall, Paul
    Arya, Farid
    Eames, Philip
    Hyde, Trevor
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 296 - 306
  • [8] OPTIMIZATION OF STATIONARY FLAT-PLATE SOLAR COLLECTORS
    Rao, Singiresu S.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 6B, 2016,
  • [9] On the Correlation between the Geometrical Features and Thermal Efficiency of Flat-Plate Solar Collectors
    Kuczynski, Waldemar
    Kaminski, Kazimierz
    Znaczko, Pawel
    Chamier-Gliszczynski, Norbert
    Piatkowski, Piotr
    ENERGIES, 2021, 14 (02)
  • [10] Efficiency of solar conversion in flat plate and vacuum tube solar collectors
    Kurpaska, S.
    Latala, H.
    Malinowski, M.
    Kielbasa, P.
    INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENTAL DEVELOPMENT, 2019, 214