Effect of thermoelectric subcooling on COP and energy consumption of a propane heat pump

被引:2
|
作者
Aranguren, P. [1 ,2 ]
Sanchez, D. [3 ]
Haida, M. [4 ]
Smolka, J. [4 ]
Cabello, R. [3 ]
Rodriguez, A. [1 ,2 ]
Astrain, D. [1 ,2 ]
机构
[1] Univ Publ Navarra, Engn Dept, Arrosadia Campus, Pamplona 31006, Spain
[2] Univ Publ Navarra, Inst Smart Cities, Arrosadia Campus, Pamplona 31006, Spain
[3] Jaume I Univ, Dep Mech Engn & Construct, Campus Riu Sec s-n, E-12071 Castellon de La Plana, Spain
[4] Silesian Tech Univ, Dept Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
关键词
Propane; Heat pump; thermoelectric subcooler; COP enhancement; Energy savings; REFRIGERATION CYCLE;
D O I
10.1016/j.applthermaleng.2024.124242
中图分类号
O414.1 [热力学];
学科分类号
摘要
The building sector has an important impact on the environment, being responsible for 30 % of the total greenhouse gas emissions. Knowing that the energy consumption devoted to HVAC systems accounts for 50 % of the total energy consumption of buildings, it is paramount to develop environmentally friendly technologies able to provide green space heating to the building sector. To that purpose, this manuscript presents a computational study on propane vapor compression heat pumps which include thermoelectric subcooling to boost their operation. The combination of these technologies has been proven in the past to be very beneficial for refrigeration systems and this study concludes for the first time that propane heat pumps can highly benefit from thermoelectric subcooling. The widely conducted research includes the following parameters: ambient temperatures from -20 to 15 degrees C, voltage supplies to the thermoelectric modules from 0.5 to 10 VDC, number of thermoelectric subcooling blocks from 1 to 8 and two water inlet temperatures, 40 and 55 degrees C to study their influence on heating capacity, compressor and thermoelectric power consumptions, subcooling degree, propane mass flow, compressor capacity, COP, energy consumption and SCOP of the combined heat pump. The obtained results are very conclusive, COP enhancements up to 12.29 % are achieved when a thermoelectric subcooler with 16 modules is included in a propane heat pump already provided with an internal heat exchanger for an ambient temperature of -20 degrees C and a water inlet temperature of 55 degrees C. Additionally, improvements in Seasonal COP up to 9.98 % are achieved if the above-mentioned technologies integration between a vapor compression heat pump and a thermoelectric subcooler substitutes a conventional propane heat pump with an internal heat exchanger for space heating a single-story two-family house.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] SIMULATION AND ANALYSIS OF DYNAMIC ENERGY CONSUMPTION OF A SEAWATER SOURCE HEAT PUMP
    Hu, Songtao
    Cao, Yu
    Liu, Kai
    Wang, Gang
    Song, Wei
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2011 - 2017
  • [32] ANALYSIS OF ENERGY-CONSUMPTION IN HEAT-PUMP AND CONVENTIONAL DRIERS
    ACEVESSABORIO, S
    HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (05): : 419 - 428
  • [33] Static analysis on energy consumption of water loop heat pump system
    Ma, Zuiliang
    Cao, Yuan
    Harbin Jianzhu Daxue Xuebao/Journal of Harbin University of Civil Engineering and Architecture, 30 (06): : 68 - 74
  • [34] Optimizing Energy Consumption Strategy of Water-loop Heat Pump
    Tu, Zhiyuan
    Peng, Fusheng
    Wang, Jie
    Huang, Chunjie
    2020 4TH INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2020), 2020, 510
  • [35] Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump
    Hu, Yifeng
    Shen, Bo
    Wan, Hanlong
    Gluesenkamp, Kyle R.
    Krishnamoorthy, Sreenidhi
    Shirey, Don
    APPLIED THERMAL ENGINEERING, 2024, 249
  • [36] Study of different subcooling control strategies in order to enhance the performance of a heat pump
    Hervas-Blasco, Estefania
    Pitarch, Miquel
    Navarro-Peris, Emilio
    Corberan, Josem.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 88 : 324 - 336
  • [37] A Modified Transcritical CO2 Heat Pump With Mechanical Subcooling for Heating
    He, Yu-Jia
    Cheng, Jia-Hao
    Chang, Meng-Meng
    Shao, Liang-Liang
    Zhang, Chun-Lu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (11): : 2771 - 2774
  • [38] Experimental research on vapor-injected heat pump using injection subcooling
    Xu Shuxue
    Niu Jianhui
    Cui Zengyan
    Ma Guoyuan
    APPLIED THERMAL ENGINEERING, 2018, 136 : 674 - 681
  • [39] Influences of the Thomson Effect on the Performance of a Thermoelectric Generator-Driven Thermoelectric Heat Pump Combined Device
    Feng, Yuanli
    Chen, Lingen
    Meng, Fankai
    Sun, Fengrui
    ENTROPY, 2018, 20 (01):
  • [40] Effects of heat reservoir temperatures on the performance of thermoelectric heat pump driven by thermoelectric generator
    Meng, Fankai
    Chen, Lingen
    Sun, Fengrui
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2010, 5 (04) : 273 - 282