A physiological perspective of the relevance of sweat biomarkers and their detection by wearable microfluidic technology: A review

被引:0
|
作者
Cinca-Morros, Sergi [1 ,2 ]
Garcia-Rey, Sandra [1 ,2 ]
Alvarez-Herms, Jesus [3 ,4 ]
Basabe-Desmonts, Lourdes [2 ,5 ]
Benito-Lopez, Fernando [1 ]
机构
[1] Univ Basque Country UPV EHU, Analyt Microsyst & Mat Lab On A Chip AMMa LOAC Grp, Microfluid Cluster UPV EHU, Analyt Chem Dept, Leioa, Spain
[2] Univ Basque Country UPV EHU, Lascaray Res Ctr, BIOMICs Microfluid Grp, Microfluid Cluster UPV EHU, Vitoria, Spain
[3] Univ Basque Country UPV EHU, Fac Sci & Technol, Dept Genet Phys Anthropol & Anim Physiol, Res Grp Sports Genom, Leioa, Spain
[4] PHYMOlab Res & Exercise Performance, Segovia, Spain
[5] Basque Fdn Sci, IKERBASQUE, Maria Diaz Haroko Kalea 3, Bilbao 48013, Spain
关键词
Sweat; Wearable devices; Microfluidics; Application; Health monitoring; Sports; HUMAN ECCRINE SWEAT; POINT-OF-CARE; EXERCISE INTENSITY; CYSTIC-FIBROSIS; LACTATE; SKIN; BLOOD; GLAND; SECRETION; EXCRETION;
D O I
10.1016/j.aca.2024.342988
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The great majority of published microfluidic wearable platforms for sweat sensing focus on the development of the technology to fabricate the device, the integration of sensing materials and actuators and the fluidics of sweat within the device. However, very few papers have discussed the physiological relevance of the metabolites measured using these novel approaches. In fact, some of the analytes present in sweat, which serve as biomarkers in blood, do not show a correlation with blood levels. This discrepancy can be attributed to factors such as contamination during measurements, the metabolism of sweat glands, or challenges in obtaining significant samples. The objective of this review is to present a critical and meaningful insight into the real applicability and potential use of wearable technology for improving health and sport performance. It also discusses the current limitations and future challenges of microfluidics, aiming to provide accurate information about the actual needs in this field. This work is expected to contribute to the future development of more suitable wearable micro- fluidic technology for health and sports science monitoring, using sweat as the biofluid for analysis.
引用
下载
收藏
页数:15
相关论文
共 43 条
  • [11] Rapid capture, extraction, and analysis of sweat samples for quantification of inflammation biomarkers using a novel wearable microfluidic system
    Zhang, M.
    Aranyosi, A.
    Lee, S.
    Model, J.
    Leech, A.
    Li, W.
    Chen, S.
    Rogers, J.
    Paller, A. S.
    Ghaffari, R.
    Xu, S.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2020, 140 (07) : S117 - S117
  • [12] Microfluidic-Based Non-Invasive Wearable Biosensors for Real-Time Monitoring of Sweat Biomarkers
    Pour, Seyedeh Rojin Shariati
    Calabria, Donato
    Emamiamin, Afsaneh
    Lazzarini, Elisa
    Pace, Andrea
    Guardigli, Massimo
    Zangheri, Martina
    Mirasoli, Mara
    BIOSENSORS-BASEL, 2024, 14 (01):
  • [13] Development of a microfluidic wearable electrochemical sensor for the non-invasive monitoring of oxidative stress biomarkers in human sweat
    Ying, Zhiye
    Qiao, Lijuan
    Liu, Bingxin
    Gao, Li
    Zhang, Peng
    BIOSENSORS & BIOELECTRONICS, 2024, 261
  • [14] Wearable Analytical Platform with Enzyme-Modulated Dynamic Range for the Simultaneous Colorimetric Detection of Sweat Volume and Sweat Biomarkers
    Vaquer, Andreu
    Baron, Enrique
    de la Rica, Roberto
    ACS SENSORS, 2021, 6 (01): : 130 - 136
  • [15] Non-enzymatic electrochemical sensor for wearable monitoring of sweat biomarkers: A mini-review
    Liu, Yu
    Liu, Tao
    Jiang, Danfeng
    CURRENT RESEARCH IN BIOTECHNOLOGY, 2023, 6
  • [16] Wearable Potentiometric Ion Patch for On-Body Electrolyte Monitoring in Sweat: Toward a Validation Strategy to Ensure Physiological Relevance
    Parrilla, Marc
    Ortiz-Gomez, Inmaculada
    Canovas, Rocio
    Salinas-Castillo, Alfonso
    Cuartero, Maria
    Crespo, Gaston A.
    ANALYTICAL CHEMISTRY, 2019, 91 (13) : 8644 - 8651
  • [17] Evaluation of sweat-based biomarkers using wearable biosensors for monitoring stress and fatigue: a systematic review
    Jie, Ma
    Li, Heng
    Anwer, Shahnawaz
    Umer, Waleed
    Antwi-Afari, Maxwell Fordjour
    Xiao, Eric Bo
    INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS, 2024, 30 (03) : 677 - 703
  • [18] Wearable IoT Security and Privacy: A Review from Technology and Policy Perspective
    D'Mello, Onyeka
    Gelin, Mathilde
    Ben Khelil, Fatma
    Surek, Rojen Erik
    Chi, Huihui
    FUTURE NETWORK SYSTEMS AND SECURITY, FNSS 2018, 2018, 878 : 162 - 177
  • [19] A Fully Elastic Wearable Electrochemical Sweat Detection System of Tree-Bionic Microfluidic Structure for Real-Time Monitoring
    Niu, Jiaqi
    Lin, Shujing
    Chen, Di
    Wang, Zhitao
    Cao, Cheng
    Gao, Ang
    Cui, Shengsheng
    Liu, Yanlei
    Hong, Yuping
    Zhi, Xiao
    Cui, Daxiang
    SMALL, 2024, 20 (11)