Control method of once-through stream generator based on active disturbance rejection control

被引:0
|
作者
Li, Muping [1 ]
Sun, Aodi [1 ]
Sun, Peiwei [1 ]
Wei, Xinyu [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Adv Nucl Energy & Technol, Xian 710049, Peoples R China
关键词
Once-through steam generator; Feed water system; Active disturbance rejection control; FAST-REACTOR; POWER;
D O I
10.1016/j.nucengdes.2024.113635
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Small lead-bismuth fast reactor(SLBFR) with pool cooling offers inherent safety features, making it suitable for diverse applications such as mobile nuclear power plants and remote power supplies However, conventional control methods often struggle to meet the demands of frequent load adjustments. To ensure the safe operation of SLBFR in the turbine-leading mode, a new control method for the once-through steam generator (OTSG) is imperative. Moreover, enhancing load-following capabilities is essential to meet operational requirements. The model of SLBFR is established in MATLAB/Simulink software to study the characteristics of OTSG operating in the turbine-leading mode. The control system of steam pressure is built by active disturbance rejection control. The load-following characteristic of core power is improved by load feedforward control modified by energy balance. Simulation results demonstrate that the adopted control method enhances the load-following capability of the OTSG. This paper serves as a valuable reference for designing the OTSG control system of SLBFR, contributing to its safe and efficient operation in various settings.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design of Control System of Once-Through Steam Generator Based on Proximal Policy Optimization Algorithm
    Li, Cheng
    Yu, Ren
    Yu, Wenmin
    Wang, Tianshu
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2022, 2022
  • [22] Enthalpy control for the feed water supply in a once-through boiler with disturbance estimation
    Backi, Christoph Josef
    IFAC PAPERSONLINE, 2017, 50 (01): : 1991 - 1996
  • [23] Water level control of U-tube steam generator based on model-based active disturbance rejection control method
    Ma, Qian
    Fan, Ziqi
    Zhang, Xianshan
    Sun, Peiwei
    Wei, Xinyu
    ANNALS OF NUCLEAR ENERGY, 2024, 206
  • [24] UAV control law design method based on active-disturbance rejection control
    Zuo L.
    Zhang X.
    Li Z.
    Qin W.
    Hou L.
    Yang S.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2024, 50 (05): : 1512 - 1522
  • [25] Precision Control of Spraying Quantity Based on Linear Active Disturbance Rejection Control Method
    Ji, Xin
    Wang, Aichen
    Wei, Xinhua
    AGRICULTURE-BASEL, 2021, 11 (08):
  • [26] Active control of combustion oscillation with active disturbance rejection control (ADRC) method
    Zhu, Hongzhi
    Weng, Fanglong
    Makeximu
    Li, Donghai
    Zhu, Min
    JOURNAL OF SOUND AND VIBRATION, 2022, 540
  • [27] THE RESEARCH OF THE MODEL-FREE ADAPTIVE CONTROL METHOD OF ONCE-THROUGH STEAM GENERATOR IN NUCLEAR POWER
    Tao, Mo
    Ke, Zhiwu
    Li, Xianling
    Qu, Ruotong
    Zhao, Zhenxing
    Wu, Jun
    Li, Yong
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 1, 2017,
  • [28] Disturbance prediction based active disturbance rejection control approach
    Li, Chongling
    Cai, Tao
    Han, Zeyu
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5896 - 5900
  • [29] Fault-tolerant control system for once-through steam generator based on reinforcement learning algorithm
    Li, Cheng
    Yu, Ren
    Yu, Wenmin
    Wang, Tianshu
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3283 - 3292
  • [30] Control strategies of grid-connection and operation based on active disturbance rejection control for virtual synchronous generator
    Li, Song
    Li, Yongli
    Chen, Xiaolong
    Jiang, Wentao
    Li, Xiangke
    Li, Tao
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 123