Round-robin test of Subsurface Damage characterization in ZERODUR® using non-destructive optical coherence tomography

被引:0
|
作者
Frank, S. [1 ]
Schwoerer, L. [2 ]
Alvan, V [3 ]
Hohmann, P. [3 ]
Burger, I [3 ]
Jedamzik, S. [3 ]
Thelemann, D. [1 ]
Wagner, M. [2 ]
Bliedtner, J. [1 ]
Boerret, R. [2 ]
机构
[1] Ernst Abbe Univ Appl Sci Jena, Carl Zeiss Promenade 2, D-07745 Jena, Germany
[2] Aalen Univ Appl Sci, Beethovenstr 1, D-73430 Aalen, Germany
[3] Schott AG, Hattenbergstr 10, D-55122 Mainz, Germany
关键词
Optical coherence tomography; Subsurface Damage; ZERODUR (R);
D O I
10.1117/12.3031491
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The glass ceramic ZERODUR (R) with its extremely low thermal expansion finds widespread application in precision optics and astronomical instruments. It has been used for several very large telescope mirrors, as its unique properties make it indispensable in environments demanding stringent dimensional stability. As for all brittle materials, mechanical grinding processes involved in manufacturing introduce subsurface damage (SSD), which compromises the optical and mechanical performance of workpieces. Beyond its implications for quality, SSD is often a significant cost driver, necessitating expensive finishing processes. Characterizing SSD and determining its depth at various manufacturing stages from pre-grinding to final polishing are critical for ensuring the quality and reliability of optical components. Conventional measurement techniques predominantly involve destructive methods such as taper polishing or cleaving the surface, posing limitations in assessing SSD without compromising the integrity of the workpiece. Moreover, these methods are often time-consuming and labor-intensive. In a collaborative study, we conducted a round-robin test to establish and validate the efficacy of non-destructive optical coherence tomography (OCT) as a new technique for characterizing SSD depths in ground ZERODUR (R). The aim is to provide a first comprehensive assessment of the capability of OCT in non-destructively quantifying SSD in glass ceramics. The methodology involves comparing measurements obtained from two distinct high-resolution OCT systems applied to identical ZERODUR (R) samples machined with selected process parameters. Furthermore, the study investigates the influence of different grain sizes on the SSD characteristics by comparing measurements across samples processed with varying grain sizes. By conducting the round-robin test, we seek to demonstrate the applicability of OCT as a non-destructive alternative for SSD characterization in ground ZERODUR (R). Successful validation of OCT extended to a variety of relevant optic materials such as ZERODUR (R) would enhance overall quality control processes, offering a rapid and non-invasive means of assessing SSD depths and ensuring the integrity of critical optical components.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Non-Destructive Analysis of the Internal Anatomical Structures of Mosquito Specimens Using Optical Coherence Tomography
    Ravichandran, Naresh Kumar
    Wijesinghe, Ruchire Eranga
    Lee, Seung-Yeol
    Choi, Kwang Shik
    Jeon, Mansik
    Jung, Hee-Young
    Kim, Jeehyun
    SENSORS, 2017, 17 (08):
  • [22] Optical Coherence Tomography for Non-Destructive Investigation of Silicon Integrated-Circuits
    Serrels, K. A.
    Renner, M. K.
    Reid, D. T.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [23] Non-destructive detection of defects in artificial skin tissue by Optical Coherence Tomography
    Schmitt, Robert
    Marx, Ulrich
    Heymer, Andrea
    Kaufmann, Michaela
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES AND SYSTEMS, 2009, : 227 - +
  • [24] Optical coherence tomography for non-destructive investigation of silicon integrated-circuits
    Serrels, K. A.
    Renner, M. K.
    Reid, D. T.
    MICROELECTRONIC ENGINEERING, 2010, 87 (09) : 1785 - 1791
  • [25] Non-destructive Inspection of Semiconductor Optical Waveguide Using Optical Coherence Tomography with Visible Broadband Light Source
    Ishida, Kazumasa
    Ozaki, Nobuhiko
    Ikeda, Naoki
    Sugimoto, Yoshimasa
    2017 22ND MICROOPTICS CONFERENCE (MOC), 2017, : 242 - 243
  • [26] Non-destructive label-free monitoring of collagen gel remodeling using optical coherence tomography
    Levitz, David
    Hinds, Monica T.
    Ardeshiri, Ardi
    Hanson, Stephen R.
    Jacques, Steven L.
    BIOMATERIALS, 2010, 31 (32) : 8210 - 8217
  • [27] Non-Destructive Inspection Methods for LEDs Using Real-Time Displaying Optical Coherence Tomography
    Cho, Nam Hyun
    Jung, Unsang
    Kim, Suhwan
    Kim, Jeehyun
    SENSORS, 2012, 12 (08) : 10395 - 10406
  • [28] Non-destructive quantification of pharmaceutical tablet coatings using terahertz pulsed imaging and optical coherence tomography
    Zhong, Shuncong
    Shen, Yao-Chun
    Ho, Louise
    May, Robert K.
    Zeitler, J. Axel
    Evans, Mike
    Taday, Philip F.
    Pepper, Michael
    Rades, Thomas
    Gordon, Keith C.
    Mueller, Ronny
    Kleinebudde, Peter
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (03) : 361 - 365
  • [29] Non-Destructive and Real-time Optical Inspection for Lens Size using Swept Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Zhao, Jinlei
    Fang, Meiqi
    Qin, Yuwei
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION XI, 2019, 11056
  • [30] Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography
    Kim, Youngseop
    Choi, Eun Sco
    Kwak, Wooseop
    Shin, Yongjin
    Jung, Woonggyu
    Ahn, Yeh-Chan
    Chen, Zhongping
    OPTICS AND LASER TECHNOLOGY, 2008, 40 (04): : 625 - 631