Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center

被引:0
|
作者
Kim, Wook [1 ]
Jee, Tae Keun [2 ]
Yeon, Je Young [2 ]
Kim, Keon Ha [1 ]
Kim, Jong-Soo [2 ]
Jeon, Pyoung [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Radiol, Sch Med, Seoul 06351, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Dept Neurosurg, Sch Med, Seoul 06351, South Korea
关键词
endovascular coil embolization; intracranial aneurysm; target tetra detachable coil; CEREBRAL ANEURYSMS; CENTER EXPERIENCE; CLASSIFICATION; PREVENTION; OUTCOMES; TRIAL; ISAT;
D O I
10.3390/jcm13164940
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Target tetra detachable coils (TTDCs) aid in achieving effective framing during the coil embolization of small intracranial aneurysms by maintaining a tetrahedral conformation within the aneurysm sac. We aimed to report the initial experience of patients treated for intracranial aneurysms using TTDCs, with a specific focus on efficacy and safety. Methods: We retrospectively reviewed the medical records of 41 patients who underwent the coil embolization of intracranial aneurysms sized <= 10 mm with TTDCs between April and May 2023. Post-procedural angiographic and clinical results were reviewed. Results: Of the 46 aneurysms (45 unruptured and 1 ruptured), 33 (71.7%) were treated with the stent-assisted technique and 13 (28.3%) using the simple coil embolization technique. Post-procedural angiography showed complete occlusion in 41 aneurysms (89.1%), neck remnants in 1 (2.2%), and residual aneurysms in 4 (8.7%). The mean packing density was 34.7% (19.3-46.8%), with TTDC coil length comprising a mean of 88.5% of the total coil length. No major device- or procedure-related complications were observed. During the follow-up, 40 aneurysms (93.0%) demonstrated complete occlusion, while neck remnants were observed in 1 (2.3%), and residual aneurysms in 2 (4.7%). No cases of recanalization were observed. Conclusions: The TTDC is a safe and effective device for the endovascular treatment of intracranial aneurysms. Follow-up studies are required to establish long-term results.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Intracranial berry aneurysms: Angiographic and clinical results after endovascular treatment
    Cognard, C
    Weill, A
    Castaings, L
    Rey, A
    Moret, J
    RADIOLOGY, 1998, 206 (02) : 499 - 510
  • [22] Endovascular coil occlusion of 473 intracranial aneurysms: angiographic and clinical results
    Alberto Vargas, Sergio
    Alberto Herrera, Diego
    William Cornejo, Jose
    BIOMEDICA, 2010, 30 (04): : 567 - 576
  • [23] Endovascular treatment of intracranial aneurysms by using Guglielmi detachable coils in awake patients: safety and feasibility
    Qureshi, AI
    Suri, MFK
    Khan, J
    Kim, SH
    Fessler, RD
    Ringer, AJ
    Guterman, LR
    Hopkins, LN
    JOURNAL OF NEUROSURGERY, 2001, 94 (06) : 880 - 885
  • [24] ENDOVASCULAR OCCLUSION OF INTRACRANIAL ANEURYSMS WITH ELECTRICALLY DETACHABLE COILS - CORRELATION OF ANEURYSM NECK SIZE AND TREATMENT RESULTS
    ZUBILLAGA, AF
    GUGLIELMI, G
    VINUELA, F
    DUCKWILER, GR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (05) : 815 - 820
  • [25] Endovascular occlusion of intracranial aneurysms with detachable coils: correlation between aneurysm neck size and treatment results
    Irie, K
    Taki, W
    Nakahara, I
    Sakai, N
    Kawanishi, M
    Kikuchi, H
    Nagao, S
    11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 879 - 885
  • [26] Clinical and Angiographic Follow-up of Ruptured Intracranial Aneurysms Treated with Endovascular Embolization
    Willinsky, R. A.
    Peltz, J.
    da Costa, L.
    Agid, R.
    Farb, R. I.
    TerBrugge, K. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (05) : 1035 - 1040
  • [27] Treatment of intracranial aneurysms using detachable coils; Initial results at a University Hospital in Pakistan
    Hamid, Rana Shoaib
    Tanveer-ul-Haq
    Chishti, Ishtiaq
    Azeemuddin, Muhammad
    Sajjad, Zafar
    Salam, Basit
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2010, 60 (08) : 638 - 641
  • [28] ENDOVASCULAR TREATMENT OF MIDDLE CEREBRAL ARTERY ANEURYSMS WITH DETACHABLE COILS: ANGIOGRAPHIC AND CLINICAL OUTCOMES IN 115 CONSECUTIVE PATIENTS
    Suzuki, Shuichi
    Tateshima, Satoshi
    Jahan, Reza
    Duckwiler, Gary R.
    Murayama, Yuichi
    Gonzalez, Nestor R.
    Vinuela, Fernando
    NEUROSURGERY, 2009, 64 (05) : 876 - 888
  • [29] Clinical and angiographic outcomes, with treatment data, for patients with cerebral aneurysms treated with Guglielmi detachable coils: A single-center experience
    Kuether, TA
    Nesbit, GM
    Barnwell, SL
    NEUROSURGERY, 1998, 43 (05) : 1016 - 1023
  • [30] Endovascular coil occlusion of 1811 intracranial aneurysms: Early angiographic and clinical results
    Henkes, H
    Fischer, S
    Weber, W
    Miloslavski, E
    Felber, S
    Brew, S
    Kuehne, D
    NEUROSURGERY, 2004, 54 (02) : 268 - 280