Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center

被引:0
|
作者
Kim, Wook [1 ]
Jee, Tae Keun [2 ]
Yeon, Je Young [2 ]
Kim, Keon Ha [1 ]
Kim, Jong-Soo [2 ]
Jeon, Pyoung [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Radiol, Sch Med, Seoul 06351, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Dept Neurosurg, Sch Med, Seoul 06351, South Korea
关键词
endovascular coil embolization; intracranial aneurysm; target tetra detachable coil; CEREBRAL ANEURYSMS; CENTER EXPERIENCE; CLASSIFICATION; PREVENTION; OUTCOMES; TRIAL; ISAT;
D O I
10.3390/jcm13164940
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Target tetra detachable coils (TTDCs) aid in achieving effective framing during the coil embolization of small intracranial aneurysms by maintaining a tetrahedral conformation within the aneurysm sac. We aimed to report the initial experience of patients treated for intracranial aneurysms using TTDCs, with a specific focus on efficacy and safety. Methods: We retrospectively reviewed the medical records of 41 patients who underwent the coil embolization of intracranial aneurysms sized <= 10 mm with TTDCs between April and May 2023. Post-procedural angiographic and clinical results were reviewed. Results: Of the 46 aneurysms (45 unruptured and 1 ruptured), 33 (71.7%) were treated with the stent-assisted technique and 13 (28.3%) using the simple coil embolization technique. Post-procedural angiography showed complete occlusion in 41 aneurysms (89.1%), neck remnants in 1 (2.2%), and residual aneurysms in 4 (8.7%). The mean packing density was 34.7% (19.3-46.8%), with TTDC coil length comprising a mean of 88.5% of the total coil length. No major device- or procedure-related complications were observed. During the follow-up, 40 aneurysms (93.0%) demonstrated complete occlusion, while neck remnants were observed in 1 (2.3%), and residual aneurysms in 2 (4.7%). No cases of recanalization were observed. Conclusions: The TTDC is a safe and effective device for the endovascular treatment of intracranial aneurysms. Follow-up studies are required to establish long-term results.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Clinical results and problems in embolization for intracranial aneurysms using electrically detachable coils
    Tsuura, M
    Terada, T
    Yokote, H
    Kinoshita, Y
    Nakai, K
    Itakura, T
    Ryujin, Y
    Hyoutani, G
    Moriwaki, H
    INTERVENTIONAL NEURORADIOLOGY, 1998, 4 : 71 - 73
  • [2] Endovascular treatment of ruptured intracranial aneurysms with detachable coils: Long-term clinical and serial angiographic results
    Sluzewski, M
    van Rooij, WJ
    Rinkel, GJE
    Wijnaida, D
    RADIOLOGY, 2003, 227 (03) : 720 - 724
  • [3] Matrix detachable coils for the endovascular treatment of intracranial aneurysms - Analysis of early angiographic and clinical outcomes
    Taschner, CA
    Leclerc, X
    Rachdi, H
    Barros, AM
    Pruvo, JP
    STROKE, 2005, 36 (10) : 2176 - 2180
  • [4] Endovascular treatment of intracranial aneurysms with Guglielmi detachable coils - Analysis of midterm angiographic and clinical outcomes
    Ng, P
    Khangure, MS
    Phatouros, CC
    Bynevelt, M
    ApSimon, H
    McAuliffe, W
    STROKE, 2002, 33 (01) : 210 - 217
  • [5] Incidence of retreatment of intracranial aneurysms primarily managed by endovascular embolization with detachable coils
    Hasan, DM
    Lee, SK
    Traynelis, VC
    Chaloupka, JC
    JOURNAL OF NEUROSURGERY, 2004, 100 (01) : A186 - A186
  • [6] Surpass NeuroEndograft for Endovascular Treatment of Intracranial Aneurysms-Single Center Clinical and Angiographic Results
    Vries, Joost D.
    Boogaarts, Jeroen
    Wakhloo, Ajay
    STROKE, 2013, 44 (02)
  • [7] Embolization of intracranial aneurysms using Gugliemi detachable coils in awake patients
    Khan, J
    Qureshi, AI
    Suri, MFK
    Guterman, LR
    Hopkins, LN
    NEUROLOGY, 2000, 54 (07) : A63 - A64
  • [8] Endovascular treatment of multiple intracranial aneurysms by using Guglielmi detachable coils
    Solander, S
    Ulhoa, A
    Viñuela, F
    Duckwiler, GR
    Gobin, YP
    Martin, NA
    Frazee, JG
    Guglielmi, G
    JOURNAL OF NEUROSURGERY, 1999, 90 (05) : 857 - 864
  • [9] Clinical and angiographic outcome after Guglielmi detachable coil embolization of intracranial aneurysms
    Darwish, B
    Rajak, S
    Wickremesekera, A
    Hunn, M
    Balakrishnan, V
    Braithwaite, D
    FitzJohn, T
    ANZ JOURNAL OF SURGERY, 2003, 73 (09) : 717 - 721
  • [10] Problems involved in endovascular embolization of intracranial aneurysms with three-dimensional Guglielmi detachable coils
    Shindo, A
    Sakai, N
    Sakai, H
    Higashi, T
    Nagata, I
    Kikuchi, H
    NEUROLOGICAL SURGERY, 2001, 29 (09): : 815 - 820