Photoacoustic/ultrasound dual-modality imaging for marker clip localization in neoadjuvant chemotherapy of breast cancer

被引:0
|
作者
Deng, Handi [1 ,2 ,3 ]
Bai, Yizhou [2 ,3 ,4 ]
Xiang, Jiaxuan [5 ]
Li, Zhaoyue [4 ]
Zhao, Peiliang [4 ]
Shi, Yawen [1 ,2 ,3 ]
Fu, Wubing [5 ]
Chen, Yuwen [1 ]
Fu, Minggang [6 ]
Ma, Cheng [1 ,2 ,3 ]
Luo, Bin [2 ,3 ,4 ]
机构
[1] Tsinghua Univ, Beijing Natl Res Ctr Informat Sci & Technol, Dept Elect Engn, Beijing, Peoples R China
[2] Tsinghua Univ, Inst Precis Healthcare, Beijing, Peoples R China
[3] Tsinghua Univ, Inst Intelligent Healthcare, Beijing, Peoples R China
[4] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Beijing, Peoples R China
[5] TsingPAI Technol Co Ltd, Beijing, Peoples R China
[6] Jinan Univ, Dept Thyroid & Galactophore Surg, Zhuhai Hosp, Zhuhai, Peoples R China
基金
中国国家自然科学基金;
关键词
PA/US dual-modality imaging; marker clip; neoadjuvant chemotherapy; tumor localization;
D O I
10.1117/1.JBO.29.S1.S11525
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: To ensure precise tumor localization and subsequent pathological examination, a metal marker clip (MC) is placed within the tumor or lymph node prior to neoadjuvant chemotherapy for breast cancer. However, as tumors decrease in size following treatment, detecting the MC using ultrasound imaging becomes challenging in some patients. Consequently, a mammogram is often required to pinpoint the MC, resulting in additional radiation exposure, time expenditure, and increased costs. Dual-modality imaging, combining photoacoustic (PA) and ultrasound (US), offers a promising solution to this issue. Aim: Our objective is to localize the MC without radiation exposure using PA/US dual-modality imaging. Approach: A PA/US dual-modality imaging system was developed. Utilizing this system, both phantom and clinical experiments were conducted to demonstrate that PA/US dual-modality imaging can effectively localize the MC. Results: The PA/US dual-modality imaging can identify and localize the MC. In clinical trials encompassing four patients and five MCs, the recognition rate was similar to 80%. Three experiments to verify the accuracy of marker position recognition were successful. Conclusions: We effectively localized the MC in real time using PA/US dualmodality imaging. Unlike other techniques, the new method enables surgeons to pinpoint nodules both preoperatively and intraoperatively. In addition, it boasts nonradioactivity and is comparatively cost-effective.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Photoacoustic and Ultrasound Dual-modality Imaging for Inflammatory Arthritis
    Xu, Guan
    Chamberland, David
    Girish, Gandikota
    Wang, Xueding
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [2] Photoacoustic and ultrasound dual-modality imaging of human peripheral joints
    Xu, Guan
    Rajian, Justin R.
    Girish, Gandikota
    Kaplan, Mariana J.
    Fowlkes, J. Brian
    Carson, Paul L.
    Wang, Xueding
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [3] Pixel based focusing for photoacoustic and ultrasound dual-modality imaging
    Yoon, Changhan
    Yoo, Yangmo
    Song, Tai-kyong
    Chang, Jin Ho
    ULTRASONICS, 2014, 54 (08) : 2126 - 2133
  • [4] Dual-Modality All-Optical Ultrasound and Photoacoustic Imaging Using Permanent Marker Ink
    Colchester, Richard J.
    Noimark, Sacha
    Zhang, Edward Z.
    Beard, Paul C.
    Desjardins, Adrien E.
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [5] Dual-modality section imaging system with optical ultrasound detection for photoacoustic and ultrasound imaging
    Nuster, Robert
    Wurzinger, Gerhild
    Gratt, Sibylle
    Paltauf, Guenther
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [6] Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer
    Alejandro Garcia-Uribe
    Todd N. Erpelding
    Arie Krumholz
    Haixin Ke
    Konstantin Maslov
    Catherine Appleton
    Julie A. Margenthaler
    Lihong V. Wang
    Scientific Reports, 5
  • [7] Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer
    Garcia-Uribe, Alejandro
    Erpelding, Todd N.
    Krumholz, Arie
    Ke, Haixin
    Maslov, Konstantin
    Appleton, Catherine
    Margenthaler, Julie A.
    Wang, Lihong V.
    SCIENTIFIC REPORTS, 2015, 5
  • [8] A novel translucent ultrasound transducer approach for dual-modality ultrasound and photoacoustic imaging
    Osman, Mohamed S.
    Creamer, Kevin
    Chen, Haoyang
    Minotto, Josiah
    Liu, Jinyun
    Agrawal, Sumit
    Kothapalli, Sri-Rajasekhar
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2022, 2022, 11960
  • [9] Thermotherapy with a photoacoustic/ultrasound dual-modality agent
    Wang, Yu-Hsin
    Liao, Ai-Ho
    Chen, Jui-Hao
    Lee, Yi-Hsien
    Wang, Churng-Ren
    Li, Pai-Chi
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [10] All-optical scanhead for ultrasound and photoacoustic dual-modality imaging
    Hsieh, Bao-Yu
    Chen, Sung-Liang
    Ling, Tao
    Guo, L. Jay
    Li, Pai-Chi
    OPTICS EXPRESS, 2012, 20 (02): : 1588 - 1596