A Radiological Comparison of Robotic-Assisted Versus Manual Techniques in Total Hip Arthroplasty

被引:0
|
作者
Annapareddy, Adarsh [1 ]
Mulpur, Praharsha [1 ]
Jayakumar, Tarun [1 ]
Shinde, Chethan [1 ]
Prasad, Vemaganti Badri Narayana [1 ]
Reddy, A. V. Gurava [1 ]
机构
[1] KIMS Sunshine Hosp, Sunshine Bone & Joint Inst, Hyderabad, India
关键词
Total hip arthroplasty; Robotic; Radiological outcomes; Robotic vs. conventional; Accuracy; Radiological measurement; Bone Ninja; ACETABULAR COMPONENT; CUP; DISLOCATION; WEAR;
D O I
10.1007/s43465-024-01232-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose This study investigates the radiological outcomes of robotic-assisted total hip arthroplasty (RATHA) compared to manual total hip arthroplasty (mTHA), addressing the ongoing debate on the effectiveness of RATHA in achieving superior implant positioning accuracy. Methods A prospective cohort of 212 patients (103 robotic, 109 manual) underwent THA and were evaluated for postoperative radiological outcomes, focusing on the inclination and anteversion angles of the acetabular cup. Outlier prevalence was assessed based on angles outside the defined Lewinnek safe zones. All post-operative measurements were made using the BoneNinja application. Results High inter-observer and intra-observer reliabilities were observed, validating the measurement accuracy. The mean anteversion and inclination angles in the RATHA cohort were 40.5 +/- 1.5 and 24.5 +/- 3.1 degrees respectively; and the mTHA cohort were 42.1 +/- 4.9 and 24.9 +/- 4.5 degrees. There was a statistically significant difference in inclination angles between the two cohorts whereas the anteversion angles showed no difference. Majority of the conventional THRs (N = 72, 55.4%) were placed outside the safe zone for anteversion. The inclination angles revealed a highly significant difference between the cohorts (p < 0.0001), with all the robotic THRs (N = 121, 100%) being placed within the safe zone for inclination, whereas only 70% (N = 91) of the conventional THRs were within the safe zone. 97.5% of RA-THRs were within 3 degrees of the proposed plan, demonstrating high accuracy. Conclusion RATHA significantly outperforms MTHA in radiological accuracy, achieving precise acetabular cup positioning with minimal outliers. These results advocate for RATHA's adoption in THA to enhance outcome predictability and affirm its reliability and safety over manual methods.
引用
下载
收藏
页码:1423 / 1430
页数:8
相关论文
共 50 条
  • [1] A Radiological Comparison of Robotic-Assisted Versus Manual Techniques in Total Hip Arthroplasty (vol 58, pg 1423, 2024)
    Annapareddy, Adarsh
    Mulpur, Praharsha
    Jayakumar, Tarun
    Shende, Chetan
    Prasad, Vemaganti Badri Narayana
    Reddy, A. V. Gurava
    INDIAN JOURNAL OF ORTHOPAEDICS, 2024, : 131 - 131
  • [2] A Comparison between Robotic-assisted and Manual Implantation of Cementless Total Hip Arthroplasty
    Nakamura, Nobuo
    Sugano, Nobuhiko
    Nishii, Takashi
    Kakimoto, Akihiro
    Miki, Hidenobu
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (04) : 1072 - 1081
  • [3] Robotic-Assisted versus Manually Implanted Total Hip Arthroplasty: A Clinical and Radiographic Comparison
    Hadley, Christopher J.
    Grossman, Eric L.
    Mont, Michael A.
    Salem, Hytham S.
    Catani, Fabio
    Marcovigi, Andrea
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 37
  • [4] Robotic-assisted versus manual total hip arthroplasty in obese patients: a retrospective case–control study
    Shuai Zhang
    Yubo Liu
    Minzhi Yang
    Mingyang Ma
    Zheng Cao
    Xiangpeng Kong
    Wei Chai
    Journal of Orthopaedic Surgery and Research, 17
  • [5] A review of robotic-assisted total hip arthroplasty
    Kwangkyoun Kim
    Seungcheol Kwon
    Junhyuk Kwon
    Jihyo Hwang
    Biomedical Engineering Letters, 2023, 13 : 523 - 535
  • [6] A review of robotic-assisted total hip arthroplasty
    Kim, Kwangkyoun
    Kwon, Seungcheol
    Kwon, Junhyuk
    Hwang, Jihyo
    BIOMEDICAL ENGINEERING LETTERS, 2023, 13 (04) : 523 - 535
  • [7] Lengths of Stay and Discharge Dispositions after Total Knee Arthroplasty: A Comparison of Robotic-Assisted and Manual Techniques
    Archer, Allison
    Salem, Hytham S.
    Coppolecchia, Andrea
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 404 - 410
  • [8] Robotic-assisted versus manual total hip arthroplasty in obese patients: a retrospective case-control study
    Zhang, Shuai
    Liu, Yubo
    Yang, Minzhi
    Ma, Mingyang
    Cao, Zheng
    Kong, Xiangpeng
    Chai, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [9] Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty
    Park, Sang Eun
    Lee, Chun Taek
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 1054 - 1059
  • [10] A comparison of radiological and clinical outcomes between robotic-assisted and conventional total hip arthroplasty: A meta-analysis
    Wang, Yuxiang
    Wang, Ruoyu
    Gong, Song
    Han, Lizhi
    Gong, Tianlun
    Yi, Yihu
    Feng, Yong
    Wang, Guohong
    Xu, Weihua
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01):