An experimental study ofAAC masonry prisms with chases under compression

被引:0
|
作者
Langstang, Gregoria K. [1 ]
Warjri, Teiborlang [1 ]
Lyngkhoi, Richard B. [1 ]
Marthong, Comingstarful [1 ]
机构
[1] Natl Inst Technol Meghalaya, Dept Civil Engn, Shillong 793003, India
关键词
autoclaved aerated concrete (AAC); chases; compressive strength; failure mode; masonry prisms; AERATED CONCRETE; STRENGTH; BEHAVIOR; WALLS;
D O I
10.12989/amr.2024.13.5.375
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Installing wiring or plumbing fixtures necessitates creating chases within masonry walls, which, while serving practical purposes, raises a crucial concern regarding the potential compromise of the masonry's structural integrity. Given these concerns, it becomes essential to thoroughly understand the impact of incorporating chases on masonry strength. In this study, 37 AAC masonry prisms (200x330x100 mm3) 3 ) were cast and tested for compression. The prisms were equipped with chases of various depths-10 mm, 20 mm and 30 mm; and orientations (horizontal, inclined, and vertical), which were then filled with mortar using 1:2, 1:4, and 1:6 cement-to-sand ratios. The primary objectives were to assess the strength decrease in the prisms with different chase characteristics compared to a control specimen and to determine the percentage strength increase due to filling materials compared to unfilled chases. Key findings indicate that as chase depth increases, there is a substantial reduction in prism strength. However, the orientation of the chase does not significantly affect strength reduction. Importantly, filling the chases with mortar leads to a significant increase in prism strength. This study not only unveils the complex impact of chase characteristics on masonry strength but also emphasizes the crucial role of filling materials in strengthening these prisms.
引用
收藏
页码:375 / 389
页数:15
相关论文
共 50 条
  • [31] Experimental Characteristics of Dry Stack Masonry under Compression and Shear Loading
    Lin, Kun
    Totoev, Yuri Zarevich
    Liu, Hongjun
    Wei, Chunli
    MATERIALS, 2015, 8 (12): : 8731 - 8744
  • [32] Experimental and Analytical Study of Masonry Subjected to Uniaxial Cyclic Compression
    Thamboo, Julian
    Bandara, Janaka
    Perera, Sithara
    Navaratnam, Satheeskumar
    Poologanathan, Keerthan
    Corradi, Marco
    MATERIALS, 2020, 13 (20) : 1 - 17
  • [33] Experimental and Numerical Study on Unreinforced Brick Masonry Walls Retrofitted with Sprayed Mortar under Uniaxial Compression
    Huang, Dawei
    Albareda, Albert
    Pons, Oriol
    BUILDINGS, 2023, 13 (01)
  • [34] Experimental Study of Interlocking Compressed Earth Block Masonry under Shear-compression Composite Action
    Wang T.
    Wang Y.
    Wu Q.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2019, 46 (09): : 62 - 68
  • [35] Core testing method to assess nonlinear behavior of brick masonry under compression: A comparative experimental study
    Jafari, Samira
    Rots, Jan G.
    Esposito, Rita
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 218 : 193 - 205
  • [36] Study of Constitution Relationship Model for Masonry under Aaxial Compression
    Liu, Wei
    Tong, Liping
    Xu, Peng
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 168-170 : 762 - 767
  • [37] Experimental and Numerical Study on the Behavior of Small-Scaled Masonry Prisms and Beams Strengthened with ECC
    Kumar, Subodh
    Rai, Durgesh C.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2024, 36 (06)
  • [38] Experimental assessment of adobe masonry assemblages under monotonic and loading–unloading compression
    Rogiros Illampas
    Ioannis Ioannou
    Dimos C. Charmpis
    Materials and Structures, 2017, 50
  • [39] Studies on brick masonry under compression
    Ding, DJ
    MATERIALS AND STRUCTURES, 1997, 30 (198) : 247 - 252
  • [40] Studies on brick masonry under compression
    Ding Dajun
    Materials and Structures, 1997, 30 (4) : 247 - 252