An experimental case study of escooter fire in a four-story building

被引:0
|
作者
Liu, X. Y. [1 ]
Ma, M. X. [1 ]
Wei, Z. L. [1 ]
Zhen, H. S. [1 ]
Wang, Y. L. [2 ]
机构
[1] Hainan Univ, Mech & Elect Engn Coll, Haikou 570228, Peoples R China
[2] Hainan Vocat Univ Sci & Technol, Mech & Elect Engn Coll, Haikou, Peoples R China
关键词
Electric bicycle fire; lithium-ion battery fire; building fire; stairwell; THERMAL RUNAWAY CHARACTERISTICS; BEHAVIOR; BATTERIES; IMPACTS; STATE;
D O I
10.1177/07349041241268991
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Driven by the necessity to understand the fire and smoke dispersion characteristics of electric bicycle (escooter) fires and their effects on residents' safety in rural houses, this study was conducted to perform full-scale fire experiments in a village house in Hainan, People's Republic of China. The tested building is a typical multi-story building representative of rural houses in southern China. It is found that an escooter fire grows rapidly once its lithium-ion battery is overcharged to ignite. Inside the stairwell where the escooters are parked, a significant increase in temperature over 60 degrees C across all floors is observed and the maximum temperature reaches up to 800 degrees C on the first floor. Furthermore, the propagation of smoke is fast, reaching the upper floors within 5 minutes and filling the entire building within 7 minutes. Due to stack effect, carbon monoxide concentration is the highest on the fourth floor, notably higher than the other floors. Closing the doors of rooms where occupants are typically present is found to effectively block heat and smoke transfer. Thus, in case an escooter's lithium-ion battery undergoes explosion combustion, it is better that residents stay in rooms by closing or even sealing the doors, waiting for help during most of the fire period. However, in case the lithium-ion battery has not been burning, there still are chances for evacuation or putting out the flame.
引用
收藏
页码:473 / 486
页数:14
相关论文
共 50 条
  • [21] Statistical Time Features-based Methodology for Fatigue Cracks Detection in a Four-Story Building
    Yanez-Borjas, Jesus J.
    Camarena-Martinez, David
    Valtierra-Rodriguez, Martin
    Amezquita-Sanchez, Juan P.
    PROCEEDINGS OF THE XXII 2020 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC 2020), VOL 4, 2020,
  • [22] Experimental Seismic Behavior of a Full-Scale Four-Story Soft-Story Wood-Frame Building with Retrofits. I: Building Design, Retrofit Methodology, and Numerical Validation
    Bahmani, Pouria
    van de Lindt, John W.
    Gershfeld, Mikhail
    Mochizuki, Gary L.
    Pryor, Steven E.
    Rammer, Douglas
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (04)
  • [24] Design Development of a Four-Story Strongback Braced Frame
    Simpson B.
    Mahin S.
    Simpson, B. (simp7@berkeley.edu), 2018, Trans Tech Publications Ltd (763 KEM) : 1050 - 1057
  • [25] Modal identification of a four-story reinforced concrete building under renovation by using ambient vibration measurement
    Areemit, N
    Yamaguchi, H
    Matsumoto, Y
    Ibi, T
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2003, : 513 - 520
  • [26] Experimental Seismic Behavior of a Full-Scale Four-Story Soft-Story Wood-Frame Building with Retrofits. II: Shake Table Test Results
    van de Lindt, John W.
    Bahmani, Pouria
    Mochizuki, Gary
    Pryor, Steven E.
    Gershfeld, Mikhail
    Tian, Jingjing
    Symans, Michael D.
    Rammer, Douglas
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (04)
  • [27] Design Implications of Large-Scale Shake-Table Test on Four-Story Reinforced Concrete Building
    Nagae, T.
    Ghannoum, W. M.
    Kwon, J.
    Tahara, K.
    Fukuyama, K.
    Matsumori, T.
    Shiohara, H.
    Kabeyasawa, T.
    Kono, S.
    Nishiyama, M.
    Sause, R.
    Wallace, J. W.
    Moehle, J. P.
    ACI STRUCTURAL JOURNAL, 2015, 112 (02) : 135 - 146
  • [28] Cyclic test of four-story steel plate shear wall
    Driver, RG
    Kulak, GL
    Kennedy, DJL
    Elwi, AE
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (02): : 112 - 120
  • [29] Seismic performance of four-story two-bay HPC frame
    Xue, Weichen
    Hu, Xiang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2007, 28 (05): : 69 - 79
  • [30] Verification of structural health assessment method using full-scale collapse test of four-story steel building
    Shinagawa, Yushi
    Mita, Akira
    STRUCTURAL HEALTH MONITORING: RESEARCH AND APPLICATIONS, 2013, 558 : 174 - +