Homogeneous B0 coil design method for open-access ultra-low field magnetic resonance imaging: A simulation study

被引:0
|
作者
Karasawa, Tomohiro [1 ]
Saikawa, Jiro [1 ]
Munaka, Tatsuya [1 ]
Kobayashi, Tetsuo [2 ]
机构
[1] Shimadzu Co Ltd, Technol Res Lab, 3-9-4 Hikaridai, Seika 6190237, Japan
[2] Kyoto Univ, Off Inst Advancement & Commun, Sakyo Ku, Kyoto 6068501, Japan
关键词
Ultra-low-field MRI; Electromagnetic coil; Multi-objective optimization;
D O I
10.1016/j.mri.2024.07.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multimodal brain function measurement system integrating functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) is expected to be a tool that will provide new insights into neuroscience. To integrate fMRI and MEG, an ultra-low-field MRI (ULF-MRI) scanner that can generate a static magnetic field (B0) with an electromagnetic coil and turn off the B0 during MEG measurements is desirable. While electromagnetic B0 coil has the above advantages, it also has a trade-off between size and the broadness of the magnetic field homogeneity. In this study, we proposed a method for designing a B0 multi-stage circular coil arrangement that determines the number of coils required to maximize magnetic field homogeneity and minimize the total wiring length of the coils. The optimized multi-stage coil arrangement had an external shape of 600 mm in diameter and a maximum height of 600 mm, with an aperture of 600 mm in diameter and 300 mm in height. The magnetic field homogeneity was <100 ppm over a 210 mm diameter spherical volume (DSV). Compared to a previous two coil pairs arrangement with the same magnetic field homogeneity, the diameter was 1/1.9 times smaller, indicating that the newly designed B0 coil arrangement realized a smaller size and wider magnetic field homogeneity.
引用
下载
收藏
页码:128 / 135
页数:8
相关论文
共 50 条
  • [1] SQUIDs for Magnetic Resonance Imaging at Ultra-low Magnetic Field
    Matlashov, A. N.
    Zotev, V. S.
    Kraus, R. H., Jr.
    Sandin, H.
    Urbaitis, A. V.
    Volegov, P. L.
    Espy, M. A.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 802 - 806
  • [2] Design of a Quadrature Receive Coil for Ultra-Low-Field Knee Magnetic Resonance Imaging
    Wan C.
    He W.
    Shen S.
    Xu Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (07): : 1923 - 1931
  • [3] Diffusion-Weighted Magnetic Resonance Imaging in an Ultra-Low Magnetic Field
    Ievleva, S. V.
    Luzhetckaia, N. V.
    Tyutyukin, K. V.
    Frolov, V. V.
    APPLIED MAGNETIC RESONANCE, 2017, 48 (07) : 699 - 706
  • [4] Diffusion-Weighted Magnetic Resonance Imaging in an Ultra-Low Magnetic Field
    S. V. Ievleva
    N. V. Luzhetckaia
    K. V. Tyutyukin
    V. V. Frolov
    Applied Magnetic Resonance, 2017, 48 : 699 - 706
  • [5] Applications of Ultra-Low Field Magnetic Resonance for Imaging and Materials Studies
    Espy, Michelle
    Flynn, Mark
    Gomez, John
    Hanson, Christina
    Kraus, Robert
    Magnelind, Per
    Maskaly, Karlene
    Matlashov, Andrei
    Newman, Shaun
    Peters, Mark
    Sandin, Henrik
    Savukov, Igor
    Schultz, Larry
    Urbaitis, Algis
    Volegov, Petr
    Zotev, Vadim
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 835 - 838
  • [6] High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil
    Savukov, Igor
    Kim, Young Jin
    Newman, Shaun
    JOURNAL OF APPLIED PHYSICS, 2022, 132 (17)
  • [7] SQUID-Based Magnetic Resonance Imaging at Ultra-Low Field Using the Backprojection Method
    Guo, Qingqian
    Ma, Changyu
    Zhang, Xin
    Xu, Yajie
    Fan, Meisheng
    Yu, Peng
    Hu, Tao
    Chang, Yan
    Yang, Xiaodong
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2020, 2020
  • [8] Development of Ultra-Low Field Magnetic Resonance Imaging System at 1 mT
    Oyama D.
    Tsuyuguchi N.
    Hirama J.
    Adachi Y.
    Kawai J.
    Journal of the Magnetics Society of Japan, 2023, 47 (04) : 118 - 127
  • [9] Electromagnetic Interference Suppression Method for an Unshielded Portable Ultra-Low Field Magnetic Resonance Imaging Scanner
    Yang, Lei
    He, Wei
    He, Yucheng
    Wu, Jiamin
    Xu, Zheng
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (15): : 4708 - 4717
  • [10] Myelin-Weighted Imaging with an Ultra-Low Field Portable Magnetic Resonance Imaging Scanner
    Dvorak, A. V.
    Balaji, S.
    Poorman, M. E.
    Sacolick, L.
    Teixeira, R. P. A. G.
    O'Halloran, R.
    Arlinghaus, L.
    Traboulsee, A.
    Williams, S. C. R.
    Deoni, S. C. L.
    Kolind, S. H.
    Ljungberg, E.
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (3_SUPPL) : 959 - 960