Performance analysis and optimization of an annular thermoelectric generator integrated with vapor chambers

被引:6
|
作者
Luo, Ding [1 ,2 ]
Li, Zheng [1 ]
Yan, Yuying [3 ]
Cao, Jin [1 ]
Zhang, Haokang [1 ]
Cao, Bingyang [2 ]
机构
[1] China Three Gorges Univ, Coll Elect Engn & New Energy, Collaborat Innovat Ctr Microgrid New Energy, Yichang, Peoples R China
[2] Tsinghua Univ, Dept Engn Mech, Key Lab Thermal Sci & Power Engn, Minist Educ, Beijing 100084, Peoples R China
[3] Univ Nottingham, Fac Engn, Univ Pk, Nottingham, England
基金
中国国家自然科学基金;
关键词
Thermoelectric generator; Waste heat recovery; Vapor chamber; Net power; Performance optimization; WASTE HEAT-RECOVERY; CONTACT RESISTANCE; MODULES; FLOW;
D O I
10.1016/j.energy.2024.132565
中图分类号
O414.1 [热力学];
学科分类号
摘要
To overcome the structural barriers of conventional annular thermoelectric generators (ATEGs), a new ATEG integrated with vapor chambers (VCs) is proposed in this paper, where the use of VCs enables a large hot-end contact area and a high temperature uniformity for traditional planar thermoelectric modules. Besides, a numerical model for the ATEG is built to conduct performance analysis and optimization under different parameters. Results suggest that the heat absorption of the ATEG increases with the increase of the number of VCs, thereby boosting the output power of the system. When the flow rate is lower than 35 g/s, the optimal number of VCs for the ATEG is 12, with the highest output power, conversion efficiency, net power, and net efficiency of 287.3 W, 5.36 %, 214.1 W, and 3.99 %, respectively, at the exhaust temperature of 800 K. Besides, the exhaust temperature does not affect the optimal result, while the ATEG should be designed with fewer VCs when applied to the waste heat recovery with a larger flow rate. The increase in the VC thermal conductivity is not related to heat absorption but can improve temperature uniformity, and the thermal conductivity of 4000 W m- 1 K- 1 already meets performance requirements. This study provides new perspectives on the structure design of ATEGs.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Performance enhancement of segmented annular thermoelectric generator based on multi-parameter and multi-objective optimization
    Sun, Yajing
    Zhai, Pengcheng
    Wang, Shuhao
    Duan, Bo
    Li, Guodong
    Chen, Gang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47
  • [32] Theoretical analysis on the performance of annular thermoelectric couple
    Shen, Zu-Guo
    Wu, Shuang-Ying
    Xiao, Lan
    ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 244 - 250
  • [33] Design optimization of a microfluidic-integrated thermoelectric power generator
    Heng, Yeh En
    Abd Manaf, Asrulnizam
    Lee, Sze Sing
    SMART MATERIALS AND STRUCTURES, 2014, 23 (08)
  • [34] Theoretical analysis and design optimization of thermoelectric generator
    Ma, Qianli
    Fang, Haisheng
    Zhang, Mengjie
    APPLIED THERMAL ENGINEERING, 2017, 127 : 758 - 764
  • [35] Geometry optimization for structural reliability and performance of a thermoelectric generator
    Naveen K. Karri
    Changki Mo
    SN Applied Sciences, 2019, 1
  • [36] Geometry optimization for structural reliability and performance of a thermoelectric generator
    Karri, Naveen K.
    Mo, Changki
    SN APPLIED SCIENCES, 2019, 1 (09):
  • [37] Performance analysis of an annular thermoelectric generator considering Thomson effect and convection heat transfer at cold junction
    Pang, Dandan
    Zhang, Aibing
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2020, 12 (06)
  • [38] Energy Conversion Performance and Optimization of Wearable Annular Thermoelectric Generators
    Chenchen Guo
    Aibing Zhang
    Dandan Pang
    Jianhua Cao
    Journal of Electronic Materials, 2023, 52 : 7325 - 7336
  • [39] Energy Conversion Performance and Optimization of Wearable Annular Thermoelectric Generators
    Guo, Chenchen
    Zhang, Aibing
    Pang, Dandan
    Cao, Jianhua
    JOURNAL OF ELECTRONIC MATERIALS, 2023, 52 (11) : 7325 - 7336
  • [40] Numerical analysis on the segmented annular thermoelectric generator for waste heat recovery
    Fan, Shifa
    Gao, Yuanwen
    ENERGY, 2019, 183 : 35 - 47