An enrichment system for glycoproteins using microfluidic paper-based analytical device with colorimetric detection

被引:0
|
作者
Zhang, Jian [1 ,2 ]
Liu, Yi [1 ]
Peng, Jiayi [1 ]
Li, Wenjing [1 ,2 ]
Miao, Yanqing [1 ,2 ]
Liu, Chunye [1 ,2 ]
机构
[1] Xian Med Univ, Sch Pharm, Xian 710021, Peoples R China
[2] Xian Med Univ, Inst Med, Xian 710021, Peoples R China
基金
中国国家自然科学基金;
关键词
Microfluidic paper-based analytical devices; Glycoproteins; Enrichment; Detachable design; Boronate; AFFINITY MONOLITHIC COLUMN; SELECTIVE ENRICHMENT; CORE; GLYCOSYLATION; RECOGNITION; BIOMARKERS; SEPARATION;
D O I
10.1016/j.microc.2024.110393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We introduce a facile method for glycoprotein enrichment, separation, and detection using microfluidic paperbased analytical devices (mu PADs). The mu PADs comprise two distinct components: the enrichment region (Chip I) and the detection section (Chip II). The reusable Chip I is fabricated by immobilizing 3-aminophenylboronic acid (APBA) onto a circular paper substrate, demonstrating exceptional glycoprotein affinity. In disposable Chip II, glycoproteins react with periodic acid, generating carbonyl compounds that produce a purple-colored product upon reacting with the Schiff reagent. Alterations in color intensity are captured using an ordinary cell phone and are subsequently analyzed using Photoshop software. Observations note a linear increase in average color intensities from 1.0 x 10- 3 to 5.0 x 10- 3 mol/L, with an R2 value of 0.9927. The relative standard deviations (RSDs) of inter-day (n = 5) and intra-day (n = 5) assessments stand at 1.5 % and 1.4 %, respectively. Our proposed approach can effectively enrich an ovalbumin (OVA) solution with concentrations as low as 1.0 x 10-11 mol/L, resulting in enrichment rates of 107 to 108 times. The interference deviations of five substances relative to OVA lie within the range of - 2.0 % to + 2.0 %. The methodology successfully enriches glycoproteins from egg white samples diluted by a factor of 1 x 106, demonstrating that the proposed method is remarkably suitable for enriching glycoproteins from authentic samples.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [11] Simultaneous Multiplexed Detection of Protein and Metal Ions by a Colorimetric Microfluidic Paper-based Analytical Device
    Xiaolu Xiong
    Junlin Zhang
    Zhou Wang
    Chenchen Liu
    Wende Xiao
    Junfeng Han
    Qingfan Shi
    BioChip Journal, 2020, 14 : 429 - 437
  • [12] Development of the simultaneous colorimetric enzymatic detection of sucrose, fructose and glucose using a microfluidic paper-based analytical device
    Aksorn, Jinakan
    Teepoo, Siriwan
    TALANTA, 2020, 207
  • [13] A colorimetric microfluidic paper-based analytical device for sulfonamides in cow milk using enzymatic inhibition
    Rafanhin Sousa, Ana Carolina
    Makara, Cleyton Nascimento
    Brazaca, Lais Canniatti
    Carrilho, Emanuel
    FOOD CHEMISTRY, 2021, 356
  • [14] Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine
    Han Zhang
    Ethan Smith
    Wei Zhang
    Anhong Zhou
    Biomedical Microdevices, 2019, 21
  • [15] Microfluidic paper-based analytical device integrated with Fe@ZnS:MIP for colorimetric detection of antibiotics
    Riaz A.
    Zareef I.
    Munawar A.
    Rakha A.
    Khan M.F.
    Akhtar S.
    Anwar A.
    Nazir S.
    Din S.
    Abbasi A.S.
    Applied Nanoscience (Switzerland), 2023, 13 (09): : 6331 - 6339
  • [16] Inkjet printed microfluidic paper-based analytical device (PAD) for glucose colorimetric detection in artificial urine
    Zhang, Han
    Smith, Ethan
    Zhang, Wei
    Zhou, Anhong
    BIOMEDICAL MICRODEVICES, 2019, 21 (03)
  • [17] Stability of Colorimetric Results in the Detection of Urine Biomarkers using a Paper-based Analytical Device
    Bertao, Ana Raquel
    Dong, Tao
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 185 - 188
  • [18] Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
    Sriram, Ganesan
    Bhat, Mahesh P.
    Patil, Pravin
    Uthappa, Uluvangada T.
    Jung, Ho-Young
    Altalhi, Tariq
    Kumeria, Tushar
    Aminabhavi, Tejraj M.
    Pai, Ranjith Krishna
    Madhuprasad
    Kurkuri, Mahaveer D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 212 - 227
  • [19] Ultrasensitive chemiluminescence detection of DNA on a microfluidic paper-based analytical device
    Yanhu Wang
    Shoumei Wang
    Shenguang Ge
    Shaowei Wang
    Mei Yan
    Dejin Zang
    Jinghua Yu
    Monatshefte für Chemie - Chemical Monthly, 2014, 145 : 129 - 135
  • [20] Ultrasensitive chemiluminescence detection of DNA on a microfluidic paper-based analytical device
    Wang, Yanhu
    Wang, Shoumei
    Ge, Shenguang
    Wang, Shaowei
    Yan, Mei
    Zang, Dejin
    Yu, Jinghua