Application of Cefaclor in Orthodontics through Micro-Implant Anchorage in Patients with Periodontitis

被引:0
|
作者
Xu, Fengxing [1 ]
机构
[1] First Peoples Hosp Yongkang City, Dept Stomatol, Yongkang 321300, Zhejiang, Peoples R China
关键词
orthodontics; cefaclor; micro-implant anchorage; CLEAR ALIGNER; THERAPY;
D O I
10.62713/aic.3281
中图分类号
R61 [外科手术学];
学科分类号
摘要
AIM: Chronic periodontitis leads to gingival swelling, hyperplasia, and tooth mobility, which affects orthodontic treatment. The aim of this study was to investigate the application of cefaclor in orthodontics through micro -implant anchorage in patients with periodontitis. METHODS: A retrospective study was conducted on patients with periodontitis who received micro -implant anchorage treatment in the department of orthodontics at the First People's Hospital of Yongkang City from July 2019 to January 2022. According to different treatment regimens, these patients were divided into the test group (patients receiving cefaclor and micro -implant anchorage treatment) and the control group (patients receiving micro -implant anchorage treatment only). The plaque index (PLI), gingival index (GI), sulcus bleeding index (SBI), and serum inflammatory factor levels were compared between the two groups after treatment. RESULTS: One hundred and five patients were included in the study, (44 males and 61 females, median age 21 [15-25] years), 51 in the cefaclor group and 54 in the no cefaclor group. After treatment, the PLI, GI, and SBI scores in the two groups were higher than those before treatment, and the levels of serum inflammatory markers significantly increased ( p < 0.05). After treatment, the PLI, GI, and SBI scores in the test group were significantly lower than those in the control group ( p < 0.001). The levels of serum interleukin-1 beta , interleukin-6, interleukin-8, and tumor necrosis factor- alpha were significantly lower in the test group, and the interleukin-2 level was higher in the test group ( p < 0.001). There was no significant difference in the incidence of complications between the two groups ( p > 0.05). CONCLUSIONS: Cefaclor and micro -implant anchorage have a good clinical effect on orthodontics in patients with periodontitis, improving periodontal health and reducing inflammatory response.
引用
收藏
页码:374 / 381
页数:8
相关论文
共 18 条
  • [1] Application and Curative Effect of Micro-implant Anchorage in Orthodontics
    Zhang, Ronghe
    Bai, Xueyan
    Zhang, Weiwei
    Song, Xiaotong
    Wang, Chunyan
    Gao, Xinxin
    Tian, Xubiao
    Liu, Fengzhen
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2016, 15 (03) : 651 - 655
  • [2] Therapeutic effect of Micro-Implant Anchorage in orthodontics
    Shi, Yarong
    Mi, Lei
    Liu, Jie
    Liu, Xiaoyao
    Hao, Yanan
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (10) : 2293 - 2298
  • [3] Clinical Application of Micro-Implant Anchorage in Initial Orthodontic Retraction
    Wahabuddin, Shaji
    Mascarenhas, Rohan
    Lqbal, Mahamad
    Husain, Akhter
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (01) : 77 - 84
  • [4] Study on the relationship between gingival crevicular fluid factor and periodontal health during micro-implant anchorage orthodontics
    Qu, Xinghui
    Ma, Yan
    Pang, Guangming
    Bao, Weiwei
    Yang, Lei
    Zhang, Fubing
    Shi, Youling
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 114 - 114
  • [5] Severe open bite with mandibular asymmetry treated using micro-implant anchorage
    Liao, Jing
    He, Shushu
    Hu, Zhiai
    Zou, Shujuan
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2017, 33 (02): : 258 - 267
  • [6] Adoption of Nano Titanium Nitride-Based Micro-Implant Anchorage in Adult Orthodontic Patients with Elongated Molars
    Liu, Zhiqiang
    Gan, Jiancheng
    Jiang, Chaoran
    Fan, Yu
    Fang, Shourong
    SCIENCE OF ADVANCED MATERIALS, 2021, 13 (06) : 1155 - 1163
  • [7] Application of Micro Implant Anchorage in Orthodontic Treatment
    Zhou, Lei
    Wang, C.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 83 : 13 - 13
  • [8] Comparative evaluation of micro-implant and headgear anchorage used with a pre-adjusted appliance system
    Ma, Junqing
    Wang, Lin
    Zhang, Weibing
    Chen, Wenjing
    Zhao, Chunyang
    Smales, Roger J.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (03) : 283 - 287
  • [9] Three dimensional finite element analysis of the initial tooth displacement in different micro implant-bone interfaces using micro-implant anchorage system
    Zhang, Lei
    Deng, Feng
    Zhang, Yi
    Fan, Yubo
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1901 - +
  • [10] Three-dimensional measurement and analysis of Mandibular Molar Distalization assisted by micro-implant anchorage combined with clear aligner
    Lin, Gengbing
    Chen, Mengwei
    Guo, Nan
    Shi, Xie
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (03) : 455 - 460