The aim of this study was to compare and evaluate the anchorage effectiveness of using either micro-implants or extraoral headgear with the McLaughlin-Bennett-Trevisi (MBT) system. Thirty young Chinese adults (14 males and 16 females) aged 18-22 years with anterior bimaxillary protrusion were divided randomly into two equal groups, treated with the MBT system anchored by either micro-implants or headgear. Nine measurements obtained before and after treatment from lateral cephalometric radiographs were assessed for the two groups, using the Mann-Whitney U test with alpha = 0.05 for statistical significance. The maxillary incisors in the micro-implant group were significantly more retracted and intruded, while the lower incisors were more lingually inclined, than in the headgear group. The occlusal and mandibular planes were rotated more counterclockwise in the micro-implant group than in the headgear group (P < 0.05). Compared with headgear anchorage, micro-implant anchorage may counteract clockwise rotation of the occlusal and mandibular planes and result in different final positions for the maxillary and mandibular incisors.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 5 条
  • [1] Treatment of an adult patient with severe dental crowding by applying asymmetric extraction, fixed appliance, and micro-implant anchorage: a case report
    Xue, Huixin
    Xu, Siyi
    Qi, Yezi
    Xue, Leilei
    Ni, Xinxin
    Xu, Liqi
    Li, Qingshan
    Lin, Jun
    BMC ORAL HEALTH, 2025, 25 (01):
  • [2] Apical root resorption in maxillary incisors when employing micro-implant and J-hook headgear anchorage: A 4-month radiographic study
    Qingzhu Wang
    Wenjing Chen
    Roger J. Smales
    Hui Peng
    Xiaokun Hu
    Lu Yin
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2012, 32 : 767 - 773
  • [3] Apical root resorption in maxillary incisors when employing micro-implant and J-hook headgear anchorage: A 4-month radiographic study
    Wang, Qingzhu
    Chen, Wenjing
    Smales, Roger J.
    Peng, Hui
    Hu, Xiaokun
    Yin, Lu
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2012, 32 (05) : 767 - 773
  • [4] Spec Rekindled-A Simple Torque Correction Mechanics for Transposed Teeth in Conjunction with Pre-adjusted Edgewise Appliance System
    Singh, Harpreet
    Maurya, Raj Kumar
    Thakkar, Surbhi
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (12) : ZH3 - ZH3
  • [5] Three dimensional finite element analysis of the initial tooth displacement in different micro implant-bone interfaces using micro-implant anchorage system
    Zhang, Lei
    Deng, Feng
    Zhang, Yi
    Fan, Yubo
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1901 - +