Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners

被引:11
|
作者
Azevedo, Luis [1 ,6 ]
Marques, Tiago [2 ]
Karasan, Duygu [3 ]
Fehmer, Vincent [4 ]
Sailer, Irena [3 ]
Correia, Andre [2 ]
Gomez-Polo, Miguel [5 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[2] Univ Catolica Portuguesa UCP, Fac Dent Med, Viseu, Portugal
[3] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[5] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[6] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, S-N Plaza Ramon y Cajal, Madrid 28040, Spain
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 01期
关键词
IMPRESSION TECHNIQUES; ACCURACY; PROSTHESES; PRECISION;
D O I
10.1016/j.prosdent.2023.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The absence of fixed reference points can affect the trueness of complete arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete arch digital implant scans is still unclear. Purpose. The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete arch digital implant scans with 5 intraoral scanners (IOSs). Material and methods. Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (alpha=.05). Results. The mean +/- standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 +/- 8 pm, 53 +/- 7 pm, and 49 +/- 11 pm, respectively, with no statistically significant differences ( P=.06). Significant differences were found for the IOSs used with each technique ( P<.001). Primescan (27 +/- 4 pm cIOSs; 28 +/- 3 pm sIOSs; 31 +/- 3 pm AL-IOSs) showed significantly higher trueness than iTero 5D (47 +/- 5 pm cIOSs; 47 +/- 4 pm sIOSs; 50 +/- 6 pm AL-IOSs) ( P=.002) and TRIOS 4 (93 +/- 18 pm cIOSs; 76 +/- 18 pm sIOSs; 107 +/- 13 pm AL-IOSs) ( P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan ( P=.348 and P=.059, respectively). Conclusions. The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete arch digital implant scans. (J Prosthet Dent 2024;132:204-210)
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [31] Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study
    Hauschild, Uli
    Lerner, Henriette
    Weigl, Paul
    Porra, Tommaso
    Admakin, Oleg
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 150
  • [32] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [33] Trueness and precision of complete arch dentate digital models produced by intraoral and desktop scanners: An ex-vivo study
    Vag, Janos
    Stevens, Clinton D.
    Badahman, Mohammed H.
    Ludlow, Mark
    Sharp, Madison
    Brenes, Christian
    Mennito, Anthony
    Renne, Walter
    JOURNAL OF DENTISTRY, 2023, 139
  • [34] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    BMC ORAL HEALTH, 2020, 20 (01)
  • [35] Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners
    Revilla-Leon, Marta
    Jiang, Peng
    Sadeghpour, Mehrad
    Piedra-Cascon, Wenceslao
    Zandinejad, Amirali
    Oezcan, Mutlu
    Krishnamurthy, Vinayak R.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03): : 372 - 378
  • [36] Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners
    Ochoa-Lopez, Gaston
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02): : 552 - 559
  • [37] The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans
    Cakmak, Gulce
    Yilmaz, Hakan
    Trevino, Alejandro
    Kokat, Ali Murat
    Yilmaz, Burak
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 533 - 541
  • [38] The effect different substrates have on the trueness and precision of eight different intraoral scanners
    Dutton, Ethan
    Ludlow, Mark
    Mennito, Anthony
    Kelly, Abigail
    Evans, Zachary
    Culp, Alexander
    Kessler, Raymond
    Renne, Walter
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (02) : 204 - 218
  • [39] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Mangano, Francesco Guido
    Bonacina, Matteo
    Mandelli, Federico
    Marchiori, Fabio
    BMC RESEARCH NOTES, 2020, 13 (01)
  • [40] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Francesco Guido Mangano
    Matteo Bonacina
    Federico Mandelli
    Fabio Marchiori
    BMC Research Notes, 13