Photo-alternating current-electrocoagulation technique: Studies on operating parameters for treatment of industrial wastewater

被引:3
|
作者
Asaithambi, Perumal [1 ]
Desta, Wendesen Mekonin [1 ]
Yesuf, Mamuye Busier [1 ]
Hussen, Mohammed [1 ]
Asmelash, Zerihun [1 ]
Beyene, Dejene [1 ]
Periyasamy, Selvakumar [2 ]
Alemayehu, Esayas [1 ,3 ]
机构
[1] Jimma Univ, Jimma Inst Technol, Fac Civil & Environm Engn, POB 378, Jimma, Ethiopia
[2] Adama Sci & Technol Univ, Sch Mech Chem & Mat Engn, Dept Chem Engn, Adama 1888, Ethiopia
[3] Addis Ababa Univ, Ctr Excellence Water Management, POB 1176, Addis Ababa, Ethiopia
关键词
Industrial wastewater; Electrocoagulation; Direct/alternating-current; Photo; COD and color removal; Usage of energy; ELECTRO-FENTON; PHOTOELECTRO-FENTON; AQUEOUS-SOLUTION; OPTIMIZATION; DEGRADATION; OXIDATION; DECOLORIZATION; COD; MINERALIZATION; COMBINATION;
D O I
10.1016/j.sciaf.2024.e02193
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this investigation, several electrochemical and advanced oxidation processes (AOPs), including photolysis (UV), direct/alternating current-electrocoagulation (DC/AC/EleC), and photo-direct/ alternating current-electrocoagulation (UV/DC/AC/EleC) process were examined regarding their capacity in order to reduce the amount of chemical oxygen demand (COD) and color in distillery industrial wastewater (DIW), as well as the effect these factors have on the amount of electricity required to treat the wastewater. Experimental results showed that compared to single UV, DC/EleC, AC/EleC, and hybrid UV/DC/EleC processes, the hybrid UV/AC/EleC process provided excellent color-100 % and COD-100 % removal efficiencies with a lowered usage of energy of 8.54 kWhr m- 3. The influence of critical operational variables such as treatment time (30-240 min), photo (8-40 W), pulse duty cycle (0.14-0.86), current (0.15-0.90 Amp), pH (1.50-11.50), chemical oxygen demand (3000-9000 mgL- 1), inter electrode spacing (1-4 cm), electrode combination (Fe/Fe, Fe/Al,Al/Fe, Al/Al), and electrolyte concentration (1-5 g L-1) on the efficiency of% color and COD removal, as well as the energy utilization of DIW were examined applying a hybrid UV/AC/EleC method. The synergistic index between UV and the AC/EleC process was also examined and discussed in this work. The UV/AC/EleC technique is the most advantageous choice in comparison to the other approaches since it can be applied to properly and efficiently remove pollutants from wastewater and industrial effluent.
引用
收藏
页数:15
相关论文
共 33 条
  • [21] Treatment of raw tannery wastewater by electrocoagulation technique: optimization of effective parameters using Taguchi method
    Deghles, Abdalhadi
    Kurt, Ugur
    DESALINATION AND WATER TREATMENT, 2016, 57 (32) : 14798 - 14809
  • [22] Treatment of textile dyeing factory wastewater by electrocoagulation with low sludge settling time: Optimization of operating parameters by RSM
    Khorram, Atousa Ghaffarian
    Fallah, Narges
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (01): : 635 - 642
  • [23] Electrocoagulation technique for continuous industrial licorice processing wastewater treatment in a single reactor employing Fe-rod electrodes: Process modeling and optimization and operating cost analysis
    Abbasi, S.
    Zinatizadeh, A. A.
    Mirghorayshi, M.
    Zinadini, S.
    McKay, T.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (02):
  • [24] Treatment of textile dyeing wastewater by electrocoagulation using Fe and Al electrodes: optimisation of operating parameters using central composite design
    Kobya, Mehmet
    Gengec, Erhan
    Sensoy, Mehmet Tonay
    Demirbas, Erhan
    COLORATION TECHNOLOGY, 2014, 130 (03) : 226 - 235
  • [25] Electrocoagulation Treatment of Wet Flue-Gas Desulfurization Wastewater Using Iron-Based Electrodes: Influence of Operating Parameters and Optimization
    Zhang, Haiyun
    Shang, Zhoutai
    Zhou, Chen
    Xue, Yunbo
    Liu, Tingfeng
    Tan, Wenyi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (03): : 3114 - 3125
  • [26] Electrocoagulation-flotation treatment followed by sedimentation of carpet cleaning wastewater: optimization of key operating parameters via RSM-CCD
    Shakeri, Elena
    Mousazadeh, Milad
    Ahmadpari, Hedieh
    Kabdasli, Isik
    Jamali, Hamzeh Ali
    Graca, Nuno S.
    Emamjomeh, Mohammad Mahdi
    DESALINATION AND WATER TREATMENT, 2021, 227 : 163 - 176
  • [27] Pollutant Removal Efficiency of Electrocoagulation Method from Industrial Wastewater: Comparison with Other Treatment Methods and Key Operational Parameters—a Comparative Study Review
    Faheem Akhter
    Suhail Ahmed Soomro
    Mohammad Siddique
    Mansoor Ahmed
    Water, Air, & Soil Pollution, 2021, 232
  • [28] Evaluation of operating parameters involved in solar photo-Fenton treatment of wastewater: Interdependence of initial pollutant concentration, temperature and iron concentration
    Zapata, A.
    Oller, I.
    Rizzo, L.
    Hilgert, S.
    Maldonado, M. I.
    Sanchez-Perez, J. A.
    Malato, S.
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2010, 97 (1-2) : 292 - 298
  • [29] Pollutant Removal Efficiency of Electrocoagulation Method from Industrial Wastewater: Comparison with Other Treatment Methods and Key Operational Parameters-a Comparative Study Review
    Akhter, Faheem
    Soomro, Suhail Ahmed
    Siddique, Mohammad
    Ahmed, Mansoor
    WATER AIR AND SOIL POLLUTION, 2021, 232 (03):
  • [30] Treatment of petroleum wastewater by electrocoagulation using scrap perforated (Fe-anode) and plate (Al and Fe-cathode) metals: Optimization of operating parameters by RSM
    Akkaya, Guelizar Kurtoglu
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 187 : 261 - 275