Comparison of fatigue lifetime of new generation CAD/CAM crown materials on zirconia and titanium abutments in implant-supported crowns: a 3D finite element analysis

被引:0
|
作者
Deste Goekay, Gonca [1 ]
Goekcimen, Guelsuem [2 ]
Oyar, Perihan [3 ]
Durkan, Rukiye [4 ]
机构
[1] Bursa Uludag Univ, Fac Dent, Dept Prosthodont, Bursa, Turkiye
[2] Ankara 75th year Oral & Dent Hlth Hosp, Dept Prosthodont, Ankara, Turkiye
[3] Hacettepe Univ, Sch Hlth Serv, Dent Prosthet Technol, Ankara, Turkiye
[4] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
关键词
finite element analysis; fatigue failure; implant abutments; implantology; material selection; FIXED DENTAL PROSTHESIS; STRESS-DISTRIBUTION; TOOTH REPLACEMENT; BONE; RESTORATIONS; PEEK; STRENGTH; PERFORMANCE; DIAMETER;
D O I
10.1515/bmt-2024-0017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives Due to the dynamic character of the stomatognathic system, fatigue life experiments simulating the cyclic loading experienced by implant-supported restorations are critical consideration. The aim of this study was to examine the effect of different crown and abutment materials on fatigue failure of single implant-supported crowns.Methods Models were created for 10 different designs of implant-supported single crowns including two zirconia-reinforced lithium silicates (crystallized and precrystallized), monolithic lithium disilicate, polymer-infiltrated ceramic networks, and polyetheretherketone supported by zirconia and titanium abutments. A cyclic load of 179 N with a frequency of 1 Hz was applied on palatal cusp of a maxillary first premolar at a 30 degrees angle in a buccolingual direction.Results In the models with titanium abutments, the polymer-infiltrated ceramic network model had a lower number of cycles to fatigue failure values in the implant (5.07), abutment (2.30), and screw (1.07) compared to others. In the models with zirconia abutments, the crystallized zirconia-reinforced lithium silicate model had a higher number of cycles to fatigue failure values in the abutment (8.52) compared to others. Depending on the fatigue criteria, polyetheretherketone implant crown could fail in less than five year while the other implant crowns exhibits an infinite life on all models.Conclusions The type of abutment material had an effect on the number of cycles to fatigue failure values for implants, abutments, and screws, but had no effect on crown materials. The zirconia abutment proved longer fatigue lifetime, and should thus be considered for implant-supported single crowns.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] The effect of different abutment and restorative crown materials on stress distribution in single-unit implant-supported restorations: A 3D finite element stress analysis
    Gokcimen, Gulsum
    Durkan, Rukiye
    Gokay, Gonca
    Oyar, Perihan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 497 - 505
  • [22] Monolithic zirconia single tooth implant-supported restorations with CAD/CAM titanium abutments in the posterior region: A 1-year prospective case series study
    Donker, Vincent J. J.
    Raghoebar, Gerry M.
    Jensen-Louwerse, Charlotte
    Vissink, Arjan
    Meijer, Henny J. A.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (01) : 125 - 132
  • [23] Stress Distribution in Splinted and Unsplinted Implant-Supported Maxillary Overdentures: A 3D Finite Element Analysis
    Geramy, Allahyar
    Habibzadeh, Sareh
    IMPLANT DENTISTRY, 2018, 27 (01) : 56 - 62
  • [24] A 3D finite element analysis of glass fiber reinforcement designs on the stress of an implant-supported overdenture
    Berger, Guilherme
    de Oliveira Pereira, Luiz Felipe
    de Souza, Evelise Machado
    Rached, Rodrigo Nunes
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05): : 865.e1 - 865.e7
  • [25] A comparative study between zirconia and titanium abutments on the stress distribution in parafunctional loading: A 3D finite element analysis
    Sivrikaya, Efe Can
    Guler, Mehmet Sami
    Bekci, Muhammed Latif
    TECHNOLOGY AND HEALTH CARE, 2020, 28 (06) : 603 - 613
  • [26] Biomechanical Assessment of Tilted Mandibular Second Molars with Full-Crown Adjacent to Implant-Supported Restoration: 3D Finite Element Analysis
    Li, Ning
    Li, Yusi
    Gao, Yiming
    Jiang, Liting
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 3459 - 3470
  • [27] Evaluation of stress distributions occurring on zirconia and titanium implant-supported prostheses: A three-dimensional finite element analysis
    Gungor, Merve Bankoglu
    Yilmaz, Handan
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (03): : 346 - 355
  • [28] Mechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysis
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    MATERIALS, 2021, 14 (17)
  • [29] Influence of implants number on the biomechanical behavior of implant-supported complete prosthesis: A 3D finite element analysis
    Aguir, Hamdi
    Mabrouk, Yosra
    Chamekh, Rayene
    Saadellaoui, Ines
    HELIYON, 2023, 9 (07)
  • [30] Effect of Framework in an Implant-Supported Full-Arch Fixed Prosthesis: 3D Finite Element Analysis
    Menini, Maria
    Pesce, Paolo
    Bevilacqua, Marco
    Pera, Francesco
    Tealdo, Tiziano
    Barberis, Fabrizio
    Pera, Paolo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (06) : 627 - 630