Comparison of fatigue lifetime of new generation CAD/CAM crown materials on zirconia and titanium abutments in implant-supported crowns: a 3D finite element analysis

被引:0
|
作者
Deste Goekay, Gonca [1 ]
Goekcimen, Guelsuem [2 ]
Oyar, Perihan [3 ]
Durkan, Rukiye [4 ]
机构
[1] Bursa Uludag Univ, Fac Dent, Dept Prosthodont, Bursa, Turkiye
[2] Ankara 75th year Oral & Dent Hlth Hosp, Dept Prosthodont, Ankara, Turkiye
[3] Hacettepe Univ, Sch Hlth Serv, Dent Prosthet Technol, Ankara, Turkiye
[4] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
关键词
finite element analysis; fatigue failure; implant abutments; implantology; material selection; FIXED DENTAL PROSTHESIS; STRESS-DISTRIBUTION; TOOTH REPLACEMENT; BONE; RESTORATIONS; PEEK; STRENGTH; PERFORMANCE; DIAMETER;
D O I
10.1515/bmt-2024-0017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives Due to the dynamic character of the stomatognathic system, fatigue life experiments simulating the cyclic loading experienced by implant-supported restorations are critical consideration. The aim of this study was to examine the effect of different crown and abutment materials on fatigue failure of single implant-supported crowns.Methods Models were created for 10 different designs of implant-supported single crowns including two zirconia-reinforced lithium silicates (crystallized and precrystallized), monolithic lithium disilicate, polymer-infiltrated ceramic networks, and polyetheretherketone supported by zirconia and titanium abutments. A cyclic load of 179 N with a frequency of 1 Hz was applied on palatal cusp of a maxillary first premolar at a 30 degrees angle in a buccolingual direction.Results In the models with titanium abutments, the polymer-infiltrated ceramic network model had a lower number of cycles to fatigue failure values in the implant (5.07), abutment (2.30), and screw (1.07) compared to others. In the models with zirconia abutments, the crystallized zirconia-reinforced lithium silicate model had a higher number of cycles to fatigue failure values in the abutment (8.52) compared to others. Depending on the fatigue criteria, polyetheretherketone implant crown could fail in less than five year while the other implant crowns exhibits an infinite life on all models.Conclusions The type of abutment material had an effect on the number of cycles to fatigue failure values for implants, abutments, and screws, but had no effect on crown materials. The zirconia abutment proved longer fatigue lifetime, and should thus be considered for implant-supported single crowns.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 503.e1 - 503.e9
  • [2] In Silico Finite Element Analysis of Implant-Supported CAD-CAM Resin Composite Crowns
    Karaer, Oguzcan
    Yamaguchi, Satoshi
    Imazato, Satoshi
    Terzioglu, Hakan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (03): : 259 - 266
  • [3] Effect of Thermomechanical Loading on the Cementation Interface of Implant-Supported CAD/CAM Crowns Luted to Titanium Abutments
    Ioannidis, Alexis
    Gil, Alfonso
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    Zinelis, Spiros
    Eliades, George
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 656 - 662
  • [4] Comparison of strains for new generation CAD-CAM implant-supported crowns under loading
    Yilmaz, Burak
    Alsaery, Amani
    Altintas, Subutay H.
    Schimmel, Martin
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 397 - 402
  • [5] Fatigue Behavior of Different CAD/CAM Materials for Monolithic, Implant-Supported Molar Crowns
    Sotto-Maior, Bruno Salles
    Carneiro, Rafael Correa
    Francischone, Carlos Eduardo
    Souza Picorelli Assis, Neuza Maria
    Devito, Karina Lopes
    Senna, Plinio Mendes
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E548 - E551
  • [6] Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis
    Gokay, Gonca Deste
    Oyar, Perihan
    Gokcimen, Gulsum
    Durkan, Rukiye
    BMC ORAL HEALTH, 2024, 24 (01):
  • [7] Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments
    Kamel, Abdullah
    Yamazaki, Toshiki
    Murakami, Natsuko
    Lyu, Huaxin
    Komine, Kohei
    Badr, Amr
    Fekry, Gehan
    Takahashi, Hidekazu
    Wakabayashi, Noriyuki
    DENTAL MATERIALS JOURNAL, 2023, 42 (03) : 336 - 342
  • [8] In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns
    Preis, Verena
    Hahnel, Sebastian
    Behr, Michael
    Bein, Laila
    RosentrittDepartment, Martin
    DENTAL MATERIALS, 2017, 33 (04) : 427 - 433
  • [9] Finite Element Analysis of Anterior Implant-Supported Restorations with Different CAD-CAM Restorative Materials
    Puengpaiboon, Usanee
    Rattanapan, Nichapat
    Pasam, Vamsi Krishna
    Sukjamsri, Chamaiporn
    EUROPEAN JOURNAL OF DENTISTRY, 2024,
  • [10] Retentive strength of implant-supported CAD-CAM lithium disilicate crowns on zirconia custom abutments using 6 different cements
    Sellers, Krysta
    Powers, John M.
    Kiat-amnuay, Sudarat
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02): : 247 - 252