Three-dimensional radial echo-planar spectroscopic imaging for hyperpolarized 13C MRSI in vivo

被引:0
|
作者
Awenius, Marcel [1 ,2 ,3 ]
Abeln, Helen [1 ,3 ,4 ]
Mueller, Melanie [1 ]
Franke, Vanessa L. [1 ]
Rincon, Gino [1 ,2 ,5 ,6 ]
Glowa, Christin [7 ,8 ,9 ,10 ]
Schmitt, Michaela [7 ,9 ,10 ,11 ]
Bangert, Renate [1 ]
Ludwig, Dominik [1 ]
Schmidt, Andreas B. [6 ,12 ,13 ]
Kuder, Tristan A. [1 ]
Ladd, Mark E. [1 ,2 ,14 ]
Bachert, Peter [1 ,2 ]
Biegger, Philipp [1 ]
Korzowski, Andreas [1 ,5 ,6 ]
机构
[1] German Canc Res Ctr, Div Med Phys Radiol, Neuenheimer Feld 223, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Fac Phys & Astron, Heidelberg, Germany
[3] Max Planck Inst Nucl Phys, Heidelberg, Germany
[4] Heidelberg Univ, Fac Chem & Earth Sci, Heidelberg, Germany
[5] German Canc Consortium DKTK, Core Ctr Heidelberg, Heidelberg, Germany
[6] German Canc Res Ctr, Heidelberg, Germany
[7] German Canc Res Ctr, Div Med Phys Radiat Oncol, Heidelberg, Germany
[8] Univ Hosp Heidelberg, Dept Radiat Oncol & Radiotherapy, Heidelberg, Germany
[9] Heidelberg Inst Radiat Oncol HIRO, Heidelberg, Germany
[10] Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[11] Heidelberg Univ, Fac Biosci, Heidelberg, Germany
[12] Univ Freiburg, Fac Med, Med Ctr, Dept Radiol,Div Med Phys, Freiburg, Germany
[13] German Canc Consortium DKTK, Partner Site Freiburg, Heidelberg, Germany
[14] Heidelberg Univ, Fac Med, Heidelberg, Germany
关键词
C-13; MRSI; dynamic nuclear polarization; echo-planar; hyperpolarization; radial; SEQUENCE; PYRUVATE;
D O I
10.1002/mrm.30258
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the feasibility of 3D echo-planar spectroscopic imaging (EPSI) technique with rapid volumetric radial k-space sampling for hyperpolarized (HP) C-13 magnetic resonance spectroscopic imaging (MRSI) in vivo. Methods: A radial EPSI (rEPSI) was implemented on a 3 T clinical PET/MR system. To enable volumetric coverage, the sinusoidal shaped readout gradients per k-t-spoke were rotated along the three spatial dimensions in a golden-angle like manner. A distance-weighted, density-compensated gridding reconstruction was used, also in cases with undersampling of spokes in k-space. Measurements without and with HP C-13-labeled substances were performed in phantoms and rats using a double-resonant C-13/H-1 volume resonator with 72 mm inner diameter. Results: Phantom measurements demonstrated the feasibility of the implemented rEPSI sequence, as well as the robustness to undersampling in k-space up to a factor of 5 without advanced reconstruction techniques. Applied to measurements with HP [1-C-13]pyruvate in a tumor-bearing rat, we obtained well-resolved MRSI datasets with a large matrix size of 12(3) voxels covering the whole imaging FOV of (180 mm)(3) within 6.3 s, enabling to observe metabolism in dynamic acquisitions. Conclusion: After further optimization, the proposed rEPSI method may be useful in applications of HP C-13-tracers where unknown or varying metabolite resonances are expected, and the acquisition of dynamic, volumetric MRSI datasets with an adequate temporal resolution is a challenge.
引用
收藏
页码:31 / 41
页数:11
相关论文
共 50 条
  • [21] Feasibility of using hyperpolarized [1-13C]lactate as a substrate for in vivo metabolic 13C MRSI studies
    Chen, Albert P.
    Kurhanewicz, John
    Bok, Robert
    Xu, Duan
    Joun, David
    Zhang, Vickie
    Nelson, Sarah J.
    Hurd, Ralph E.
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 721 - 726
  • [22] Three dimensional radial echo planar imaging for functional MRI
    Rettenmeier, Christoph A.
    Maziero, Danilo
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 193 - 206
  • [23] In vivo 31P echo-planar spectroscopic imaging of human calf muscle
    Wilhelm, T
    Bachert, P
    JOURNAL OF MAGNETIC RESONANCE, 2001, 149 (01) : 126 - 130
  • [24] Deuterium echo-planar spectroscopic imaging (EPSI) in the human liver in vivo at 7 T
    Nam, Kyung Min
    Gursan, Ayhan
    Bhogal, Alex A.
    Wijnen, Jannie P.
    Klomp, Dennis W. J.
    Prompers, Jeanine J.
    Hendriks, Arjan D.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) : 863 - 874
  • [25] Metabolic response of glioma to dichloroacetate measured in vivo by hyperpolarized 13C magnetic resonance spectroscopic imaging
    Park, Jae Mo
    Recht, Lawrence D.
    Josan, Sonal
    Merchant, Milton
    Jang, Taichang
    Yen, Yi-Fen
    Hurd, Ralph E.
    Spielman, Daniel M.
    Mayer, Dirk
    NEURO-ONCOLOGY, 2013, 15 (04) : 433 - 441
  • [26] Three-dimensional echo-planar cine imaging of cerebral blood supply using arterial spin labeling
    Manoj Shrestha
    Toralf Mildner
    Torsten Schlumm
    Scott Haile Robertson
    Harald Möller
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 799 - 810
  • [27] Breath-hold MR cholangiopancreatography with three-dimensional, segmented, echo-planar imaging and volume rendering
    Wielopolski, PA
    Gaa, J
    Wielopolski, DR
    Oudkerk, M
    RADIOLOGY, 1999, 210 (01) : 247 - 252
  • [28] Three-dimensional echo-planar cine imaging of cerebral blood supply using arterial spin labeling
    Shrestha, Manoj
    Mildner, Toralf
    Schlumm, Torsten
    Robertson, Scott Haile
    Moeller, Harald
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (06) : 799 - 810
  • [29] 3-DIMENSIONAL ECHO-PLANAR MR SPECTROSCOPIC IMAGING AT SHORT ECHO TIMES IN THE HUMAN BRAIN
    POSSE, S
    DECARLI, C
    LEBIHAN, D
    RADIOLOGY, 1994, 192 (03) : 733 - 738
  • [30] Quantification of in vivo metabolic kinetics of hyperpolarized pyruvate in rat kidneys using dynamic 13C MRSI
    Xu, Tao
    Mayer, Dirk
    Gu, Meng
    Yen, Yi-Fen
    Josan, Sonal
    Tropp, James
    Pfefferbaum, Adolf
    Hurd, Ralph
    Spielman, Daniel
    NMR IN BIOMEDICINE, 2011, 24 (08) : 997 - 1005