Novel Technique for Ultra-Trace Determination of Lead in Seawater Samples Using Gold Coated Tungsten Coil Atom Trap Hydride Generation Atomic Absorption Spectrometry

被引:2
|
作者
Atasoy, Muhammet [1 ]
机构
[1] Mugla Sitki Kocman Univ, Mugla Vocat Sch, Chem & Chem Treatment Technol Dept, Chem Technol Program, TR-48000 Mugla, Turkiye
来源
CHEMISTRYSELECT | 2024年 / 9卷 / 32期
关键词
Lead determination; Trap; Au-coated W-coil; Hydride generation; Seawater analysis; SOLID-PHASE EXTRACTION; VAPOR GENERATION; PRECONCENTRATION; INTERFERENCE; BISMUTH; WATER; MICROEXTRACTION; PERFORMANCE; ADSORBENT; SELENIUM;
D O I
10.1002/slct.202402842
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel and simple trap technique combining a gold-coated tungsten coil with hydride generation atomic absorption spectrometry (HGAAS) were developed for ultra-trace lead determination. The technique was based on first transporting the plumbane produced by the HG system, together with H-2, to a trap externally heated to 92 degrees C, where it was collected for in-situ preconcentration and then volatilized by raising the trap temperature to 510 degrees C. For a 120 s trapping time, the limit of detection (LOD) was 2.9 ng L-1, the limit of quantification (LOQ) was 9.7 ng L-1 and the relative standard deviation was 3.1 % (at 0.02 mu g L-1). The analytical performance of the technique was contrasted against the classical HGAAS method and a 39.2-fold increase in sensitivity was obtained when comparing the characteristic concentrations of both methodologies. The morphology of the trap surface was also studied using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The accuracy of the proposed method was verified by analyzing the Pb concentration in the certified reference materials and the results agreed well with the certified values. Finally, the developed procedure was successfully applied to seawater samples and the recoveries of standard addition were between 102.4 % and 105.2 %.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] DETERMINATION OF LEAD IN FOODSTUFFS AND BIOLOGICAL SAMPLES BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY USING AN AQUEOUS SLURRY TECHNIQUE
    MADRID, Y
    BONILLA, M
    CAMARA, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (02) : 167 - 169
  • [22] Determination of trace lead in waters by flow injection hydride generation atomic absorption spectrometry
    Carrijo, JFN
    Brasil, LC
    Coelho, NVM
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (3B) : 520 - 525
  • [23] Flow injection on-line preconcentration coupled to hydride generation atomic fluorescence spectrometry for ultra-trace amounts of cadmium determination in seawater
    Hong Wu
    Chao Fang
    Baixiang Du
    Changchun Zhao
    Microchimica Acta, 2008, 160 : 173 - 178
  • [24] Flow injection on-line preconcentration coupled to hydride generation atomic fluorescence spectrometry for ultra-trace amounts of cadmium determination in seawater
    Wu, Hong
    Fang, Chao
    Du, Baixiang
    Zhao, Changchun
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 173 - 178
  • [25] Determination of ultra-trace amounts of selenium in environmental samples by sequential injection-hydride generation-nondispersive atomic fluorescence spectrometry
    Wang, Z
    Fan, SH
    Fang, ZL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (02) : 195 - 197
  • [26] Determination of ultra-trace selenium in mineral samples by hydride generation atomic fluorescence spectrometry with pressurized-PTFE-vessel acid digestion
    Zhang, Ni
    Sun, Genling
    Ma, Hairui
    MINERALS ENGINEERING, 2007, 20 (15) : 1397 - 1400
  • [27] Atomic absorption spectrometric determination of trace tellurium after hydride trapping on platinum-coated tungsten coil
    Xi, Maoyang
    Liu, Rui
    Wu, Peng
    Xu, Kailai
    Hou, Xiandeng
    Lv, Yi
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 320 - 325
  • [28] DETERMINATION OF ULTRA-TRACE GOLD IN ORES BY GRAPHITE-FURNACE ZEEMAN ATOMIC-ABSORPTION SPECTROMETRY
    SHIMIZU, H
    ONOUE, T
    MURAYAMA, T
    BUNSEKI KAGAKU, 1984, 33 (12) : T123 - T126
  • [29] A robust method for the determination of lead in water samples using flow injection hydride generation atomic absorption spectrometry
    Schlotthauer, Jonatan
    Mantaras, Leyla
    Brusa, Lucila
    Sigrist, Mirna
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 212
  • [30] Determination of ultra trace arsenic species in water samples by hydride generation atomic absorption spectrometry after cloud point extraction
    Ulusoy, Halil Ibrahim
    Akcay, Mehmet
    Ulusoy, Songul
    Gurkan, Ramazan
    ANALYTICA CHIMICA ACTA, 2011, 703 (02) : 137 - 144