Reliability and minimal detectable change of dynamic temporal summation and conditioned pain modulation using a single experimental paradigm

被引:1
|
作者
Vincenot, Matthieu [1 ,2 ]
Beaulieu, Louis-David [3 ]
Gendron, Louis [4 ,5 ]
Marchand, Serge [5 ,6 ]
Leonard, Guillaume [1 ,7 ]
机构
[1] CIUSSS Estrie CHUS, Res Ctr Aging, Sherbrooke, PQ, Canada
[2] Univ Sherbrooke, Fac Med & Hlth Sci, Sherbrooke, PQ, Canada
[3] Univ Quebec Chicoutimi, BioNR Res Lab, Chicoutimi, PQ, Canada
[4] Univ Sherbrooke, Fac Med & Hlth Sci, Dept Pharmacol Physiol, Sherbrooke, PQ, Canada
[5] Ctr Hosp Univ Sherbrooke, Res Ctr, Sherbrooke, PQ, Canada
[6] Univ Sherbrooke, Fac Med & Hlth Sci, Dept Surg, Sherbrooke, PQ, Canada
[7] Univ Sherbrooke, Fac Med & Hlth Sci, Sch Rehabil, Sherbrooke, PQ, Canada
来源
PLOS ONE | 2024年 / 19卷 / 07期
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
TEST-RETEST RELIABILITY; MAGNETIC STIMULATION OUTCOMES; STATISTICAL-METHODS; MECHANISMS; AGREEMENT; SMOKING; ADULTS;
D O I
10.1371/journal.pone.0307556
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Quantitative sensory tests (QST) are frequently used to explore alterations in somatosensory systems. Static and dynamic QST like pain threshold and temporal summation (TS) and conditioned pain modulation (CPM) are commonly used to evaluate excitatory and inhibitory mechanisms involved in pain processing. The aim of the present study was to document the reliability and the minimal detectable change (MDC) of these dynamic QST measurements using a standardized experimental paradigm.Material and methods Forty-six (46) pain-free participants took part in 2 identical sessions to collect TS and CPM outcomes. Mechanical (pressure pain threshold [PPT]) and thermal (constant 2-minute heat pain stimulation [HPS]) nociceptive stimuli were applied as test stimuli, before and after a cold-water bath (conditioning stimulus). TS was interpreted as the change in pain perception scores during HPS. CPM were determined by calculating the difference in pain perception between pre- and post- water bath for both PPT and HPS. Relative and absolute reliability were analyzed with intra-class correlation coefficient (ICC2, k), standard error of the measurements (SEMeas) and MDC.Results Results revealed a good to excellent relative reliability for static QST (ICC >= 0.73). For TS, a poor to moderate relative reliability depending on the calculation methods (ICC = 0.25 <= ICC <= 0.59), and a poor relative reliability for CPM (ICC = 0.16 <= ICC <= 0.37), both when measured with mechanical stimulation (PPT) and thermal stimulation (HPS). Absolute reliability varied from 0.73 to 7.74 for static QST, 11 to 22 points for TS and corresponded to 11.42 points and 1.56 points for thermal and mechanical-induced CPM, respectively. MDC analyses revealed that a change of 1.58 to 21.46 point for static QST, 31 to 52 points for TS and 4 to 31 points for CPM is necessary to be interpreted as a real change.Conclusion Our approach seems well-suited to clinical use. Although our method shows equivalent relative and absolute reliability compared to other protocols, we found that the reliability of endogenous pain modulation mechanisms is vulnerable, probably due to its dynamic nature.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Test-Retest, Interrater Reliability, and Minimal Detectable Change of the Dynamic Exertion Test (EXiT) for Concussion
    Sinnott, Aaron M.
    Eagle, Shawn R.
    Kochick, Victoria
    Collins, Michael W.
    Elbin, R. J.
    Connaboy, Christopher
    Kontos, Anthony P.
    Bricker, Indira R.
    Sparto, Patrick J.
    Flanagan, Shawn D.
    SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2023, 15 (03): : 410 - 421
  • [32] Reliability and Minimum Detectable Change of Temporal-Spatial, Kinematic, and Dynamic Stability Measures during Perturbed Gait
    Rabago, Christopher A.
    Dingwell, Jonathan B.
    Wilken, Jason M.
    PLOS ONE, 2015, 10 (11):
  • [33] Pressure pain threshold and temporal summation of the vulvar vestibule: reliability of a new approach using an electronic vulvalgesiometer
    Antonio, F.
    Rodrigues, M.
    Pukall, C.
    Tremblay, F.
    McLean, L.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2020, 31 (SUPPL 1) : S234 - S234
  • [34] Is the Conditioned Pain Modulation Paradigm Reliable? A Test-Retest Assessment Using the Nociceptive Withdrawal Reflex
    Manresa, Jose A. Biurrun
    Fritsche, Raphael
    Vuilleumier, Pascal H.
    Oehler, Carmen
    Morch, Carsten D.
    Arendt-Nielsen, Lars
    Andersen, Ole K.
    Curatolo, Michele
    PLOS ONE, 2014, 9 (06):
  • [35] Reliability and minimal detectable change of a modified passive neck flexion test in patients with chronic nonspecific neck pain and asymptomatic subjects
    Lopez-de-Uralde-Villanueva, Ibai
    Acuyo-Osorio, Mario
    Prieto-Aldana, Maria
    La Touche, Roy
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2017, 28 : 10 - 17
  • [36] The reliability, variability and minimal detectable change of multiplanar isometric trunk strength testing using a fixed digital dynamometer
    Bucke, Jonathan
    Mattiussi, Adam
    May, Karen
    Shaw, Joseph
    JOURNAL OF SPORTS SCIENCES, 2024, 42 (09) : 840 - 846
  • [37] Test-retest reliability and minimal detectable change of the computerized dynamic posturography PROPRIO for adults with chronic traumatic brain injury
    Cesar, Guilherme M.
    Buster, Thad W.
    Burnfield, Judith M.
    DISABILITY AND REHABILITATION, 2021, 43 (14) : 2038 - 2044
  • [38] Test-retest reliability and minimal detectable change of three-dimensional gait analysis in chronic low back pain patients
    Fernandes, Rita
    Armada-da-Silva, Paulo
    Pool-Goudaazward, Annelies
    Moniz-Pereira, Vera
    Veloso, Antonio P.
    GAIT & POSTURE, 2015, 42 (04) : 491 - 497
  • [39] Change in pain expectations but no open-label placebo analgesia: An experimental study using the heat pain paradigm
    Friehs, Thilo
    Milde, Christopher
    Glombiewski, Julia Anna
    Kube, Tobias
    EUROPEAN JOURNAL OF PAIN, 2024, 28 (05) : 769 - 785
  • [40] Reliability and minimal detectable change of spinal length and width measurements using the Flexicurve for usual standing posture in healthy young adults
    Dunleavy, Kim
    Mariano, Herman
    Wiater, Timothy
    Goldberg, Allon
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2010, 23 (04) : 209 - 214