Identification of a lumped-parameter model of the intervertebral joint from experimental data

被引:0
|
作者
Gould, Samuele L. [1 ,2 ]
Davico, Giorgio [1 ,2 ]
Palanca, Marco [1 ]
Viceconti, Marco [1 ,2 ]
Cristofolini, Luca [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Ind Engn, Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Med Technol Lab, Bologna, Italy
关键词
musculoskeletal modelling; intervertebral joint; stiffness; sensitivity; personalisation; specimen-specific; multibody modelling; THORACOLUMBAR SPINE MODEL; MUSCULOSKELETAL MODEL; HUMAN LUMBAR; MECHANICAL-PROPERTIES; INTRADISCAL PRESSURE; STEPWISE REDUCTION; PASSIVE ELEMENTS; MULTIBODY MODEL; MOTION SEGMENTS; MUSCLE FORCES;
D O I
10.3389/fbioe.2024.1304334
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Through predictive simulations, multibody models can aid the treatment of spinal pathologies by identifying optimal surgical procedures. Critical to achieving accurate predictions is the definition of the intervertebral joint. The joint pose is often defined by virtual palpation. Intervertebral joint stiffnesses are either derived from literature, or specimen-specific stiffnesses are calculated with optimisation methods. This study tested the feasibility of an optimisation method for determining the specimen-specific stiffnesses and investigated the influence of the assigned joint pose on the subject-specific estimated stiffness. Furthermore, the influence of the joint pose and the stiffness on the accuracy of the predicted motion was investigated. A computed tomography based model of a lumbar spine segment was created. Joints were defined from virtually palpated landmarks sampled with a Latin Hypercube technique from a possible Cartesian space. An optimisation method was used to determine specimen-specific stiffnesses for 500 models. A two-factor analysis was performed by running forward dynamic simulations for ten different stiffnesses for each successfully optimised model. The optimisations calculated a large range of stiffnesses, indicating the optimised specimen-specific stiffnesses were highly sensitive to the assigned joint pose and related uncertainties. A limited number of combinations of optimised joint stiffnesses and joint poses could accurately predict the kinematics. The two-factor analysis indicated that, for the ranges explored, the joint pose definition was more important than the stiffness. To obtain kinematic prediction errors below 1 mm and 1 degrees and suitable specimen-specific stiffnesses the precision of virtually palpated landmarks for joint definition should be better than 2.9 mm.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A 3-DIMENSIONAL LUMPED-PARAMETER MODEL FOR MHD DEVICES
    GERI, A
    VECA, GM
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 1992, 11 (01) : 233 - 236
  • [22] A saturating lumped-parameter model for an interior PM synchronous machine
    Lovelace, EC
    Jahns, TM
    Lang, JH
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (03) : 645 - 650
  • [23] A Lumped-Parameter Model of Multiscale Dynamics in Steam Supply Systems
    Hoshino, Hikaru
    Susuki, Yoshihiko
    Hikihara, Takashi
    JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS, 2016, 11 (06):
  • [24] Lumped-Parameter Thermal Model and Testing of Permanent Magnet Machine
    Li Ye
    Fan Tao
    Li Qi
    Wen XuHui
    2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,
  • [25] Inverse Thermal Identification of a Thermally Instrumented Induction Machine Using a Lumped-Parameter Thermal Model
    Pieter Nguyen Phuc
    Vansompel, Hendrik
    Bozalakov, Dimitar
    Stockman, Kurt
    Crevecoeur, Guillaume
    ENERGIES, 2020, 13 (01)
  • [26] Experimental investigation and lumped-parameter model of the cooling system of an ICE under nucleate boiling conditions
    Bova, S.
    Castiglione, T.
    Piccione, R.
    Pizzonia, F.
    Belli, M.
    69TH CONFERENCE OF THE ITALIAN THERMAL ENGINEERING ASSOCIATION, ATI 2014, 2015, 81 : 907 - 917
  • [28] A lumped-parameter model for kidney pressure during stone removal
    Williams, J. G.
    Rouse, L.
    Turney, B. W.
    Waters, S. L.
    Moulton, D. E.
    IMA JOURNAL OF APPLIED MATHEMATICS, 2020, 85 (05) : 703 - 723
  • [29] LUMPED-PARAMETER MODEL OF MASS-TRANSFER IN HEMODIALYZER WITH ULTRAFILTRATION
    ZHANG, FB
    ZHANG, GL
    CHEN, T
    WANG, ST
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1995, 3 (01) : 57 - 62
  • [30] A patient-specific lumped-parameter model of coronary circulation
    Zheng Duanmu
    Min Yin
    Xueling Fan
    Xilan Yang
    Xiaoyu Luo
    Scientific Reports, 8