Identification of a lumped-parameter model of the intervertebral joint from experimental data

被引:0
|
作者
Gould, Samuele L. [1 ,2 ]
Davico, Giorgio [1 ,2 ]
Palanca, Marco [1 ]
Viceconti, Marco [1 ,2 ]
Cristofolini, Luca [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Ind Engn, Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Med Technol Lab, Bologna, Italy
关键词
musculoskeletal modelling; intervertebral joint; stiffness; sensitivity; personalisation; specimen-specific; multibody modelling; THORACOLUMBAR SPINE MODEL; MUSCULOSKELETAL MODEL; HUMAN LUMBAR; MECHANICAL-PROPERTIES; INTRADISCAL PRESSURE; STEPWISE REDUCTION; PASSIVE ELEMENTS; MULTIBODY MODEL; MOTION SEGMENTS; MUSCLE FORCES;
D O I
10.3389/fbioe.2024.1304334
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Through predictive simulations, multibody models can aid the treatment of spinal pathologies by identifying optimal surgical procedures. Critical to achieving accurate predictions is the definition of the intervertebral joint. The joint pose is often defined by virtual palpation. Intervertebral joint stiffnesses are either derived from literature, or specimen-specific stiffnesses are calculated with optimisation methods. This study tested the feasibility of an optimisation method for determining the specimen-specific stiffnesses and investigated the influence of the assigned joint pose on the subject-specific estimated stiffness. Furthermore, the influence of the joint pose and the stiffness on the accuracy of the predicted motion was investigated. A computed tomography based model of a lumbar spine segment was created. Joints were defined from virtually palpated landmarks sampled with a Latin Hypercube technique from a possible Cartesian space. An optimisation method was used to determine specimen-specific stiffnesses for 500 models. A two-factor analysis was performed by running forward dynamic simulations for ten different stiffnesses for each successfully optimised model. The optimisations calculated a large range of stiffnesses, indicating the optimised specimen-specific stiffnesses were highly sensitive to the assigned joint pose and related uncertainties. A limited number of combinations of optimised joint stiffnesses and joint poses could accurately predict the kinematics. The two-factor analysis indicated that, for the ranges explored, the joint pose definition was more important than the stiffness. To obtain kinematic prediction errors below 1 mm and 1 degrees and suitable specimen-specific stiffnesses the precision of virtually palpated landmarks for joint definition should be better than 2.9 mm.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A LUMPED-PARAMETER MODEL FOR INFILTRATION
    PINGOUD, K
    JOURNAL OF HYDROLOGY, 1982, 57 (1-2) : 175 - 185
  • [2] Identification of a lumped-parameter model for golf balls in normal impact
    Nakai, K.
    Yokoyama, T.
    ADVANCES IN EXPERIMENTAL MECHANICS V, 2007, 7-8 : 237 - +
  • [3] SENSITIVITY ANALYSIS OF A LUMPED-PARAMETER MODEL FOR INFILTRATION
    PINGOUD, K
    JOURNAL OF HYDROLOGY, 1984, 67 (1-4) : 97 - 113
  • [4] LUMPED-PARAMETER MODEL FOR INVIVO COCHLEAR STIMULATION
    SUESSERMAN, MF
    SPELMAN, FA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (03) : 237 - 245
  • [5] Lumped-parameter thermal model for induction machines
    Durán, MJ
    Fernández, J
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) : 791 - 792
  • [6] Lumped-parameter inertia model for flexure hinges
    Lobontiu, N
    Garcia, E
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2004, 32 (01) : 73 - 99
  • [7] PARAMETER SENSITIVITY ANALYSIS OF A LUMPED-PARAMETER MODEL OF LYMPHANGIONS IN SERIES
    Jamalian, Samira
    Moore, James E., Jr.
    Bertram, Christopher D.
    Richardson, Will
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 345 - 346
  • [8] Lumped-parameter model for dynamic monolayer graphene sheets
    Wei, Dongming
    Nurakhmetov, Daulet
    Aniyarov, Almir
    Zhang, Dichuan
    Spitas, Christos
    JOURNAL OF SOUND AND VIBRATION, 2022, 534
  • [9] Study on Lumped-parameter Model of Surface Circular Foundation
    Wang, Hai
    Liu, Weiqing
    Wang, Shuguang
    Du, Dongsheng
    Zhou, Ding
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 261-263 : 980 - 984
  • [10] A female-specific cardiovascular lumped-parameter model
    Comunale, Giulia
    Susin, Francesca M.
    Mynard, Jonathan P.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2654 - 2657