Enhancing the building resilience in a changing climate through a passive cooling roof: A case study in Camas (Seville, Spain)

被引:1
|
作者
Palma, Rafael Monge [1 ]
Medina, Daniel Castro [2 ]
Delgado, MCarmen Guerrero [1 ]
Ramos, Jose Sanchez [1 ]
Montero-Gutierrez, Paz [1 ]
Dominguez, Servando Alvarez [1 ]
机构
[1] Univ Seville, Grp Termotecnia, Escuela Super Ingn, Seville, Spain
[2] Univ Cadiz, Escuela Super Ingn, Grp Termotecnia, Cadiz, Spain
关键词
Resilient buildings; Passive cooling; Double-skin roof; Thermal comfort; Energy poverty; ADAPTIVE THERMAL COMFORT; NIGHT VENTILATION; RESIDENTIAL BUILDINGS; ENERGY PERFORMANCE; SOLAR CHIMNEY; RENOVATION; SIMULATION; STRATEGIES; STANDARDS; DESIGN;
D O I
10.1016/j.enbuild.2024.114680
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Renovating buildings is a crucial mission for the coming decades to combat energy inefficiencies and produce a resilient building stock. The inefficient thermal envelope has significant implications for occupants, especially for families lacking the financial resources to maintain a healthy and comfortable indoor environment. In scenarios where households cannot afford or utilize HVAC systems and high temperatures are more frequent, building retrofits should prioritize reducing heat loss in winter and passively lowering indoor temperatures in the cooling season. This work introduces a new solution to enhance the liveability of a social housing building in southern Spain by integrating a double-skin roof with a conventional retrofit strategy, which incorporates passive cooling techniques - night ventilation and an evaporative cooling system - for effective heat dissipation based on available commercial solutions. An extensive monitoring campaign was conducted over three years to evaluate the thermal comfort of occupants and the risk of overheating in naturally conditioned buildings before and after renovation following two impact assessment methods: real-time data-based and simulation-based. The real-time data-based method compared the indoor conditions of a dwelling with a conventionally retrofitted roof to one with a double-skin roof, indicating that the dynamic roof maintains a ceiling temperature lower than the air temperature throughout the summer while the conventional roof acts as a heating surface. On the other side, the simulation-based method compared the observed indoor conditions with a double-skin roof enabled during 2023 to the initial stage and a double-skin roof disabled scenario, using calibrated building energy models. The natural cooling roof solution almost eliminates the overheating events, leading to a reduction of 94.1% and 76.9% in discomfort degree-hours compared to the initial stage according to the ASHRAE adaptative and Fanger comfort models, respectively. Additionally, the results indicate that conventional retrofits can increase the risk of overheating when a cooling system is not considered. Integrating a cool roof solution requires only an extra implementation cost of 31<euro>/m2 compared to a conventional solution, having an operational cost that represents less than 3% of the minimum monthly income in the social housing district.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A comparative LCA study of passive cooling roof materials for a residential building: An Indian Case study
    Sravani, Tata
    Ramani, Prasanna Venkatesan
    Anbu, Madhumathi
    MATERIALS TODAY-PROCEEDINGS, 2022, 64 : 1014 - 1022
  • [2] A comparative LCA study of passive cooling roof materials for a residential building: An Indian Case study
    Sravani, Tata
    Prasanna Venkatesan, Ramani
    Madhumathi, Anbu
    Materials Today: Proceedings, 2022, 64 : 1014 - 1022
  • [3] Estimating building cooling energy demand through the Cooling Degree Hours in a changing climate: A modeling study
    Salata, Ferdinando
    Falasca, Serena
    Ciancio, Virgilio
    Curci, Gabriele
    Grignaffini, Stefano
    de Wilde, Pieter
    SUSTAINABLE CITIES AND SOCIETY, 2022, 76
  • [4] Application of passive cooling systems in the hot and humid climate: The case study of solar chimney and wetted roof in Thailand
    Chungloo, Sudaporn
    Limmeechokchai, Bundit
    BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3341 - 3351
  • [5] Building climate change resilience through local cooperation: a Peruvian Andes case study
    Caitlin A. Doughty
    Regional Environmental Change, 2016, 16 : 2187 - 2197
  • [6] Building climate change resilience through local cooperation: a Peruvian Andes case study
    Doughty, Caitlin A.
    REGIONAL ENVIRONMENTAL CHANGE, 2016, 16 (08) : 2187 - 2197
  • [7] A study of the passive cooling potential in simulated building in Latvian climate conditions
    Prozuments, A.
    Vanags, I.
    Borodinecs, A.
    Millers, R.
    Tumanova, K.
    3RD INTERNATIONAL CONFERENCE ON INNOVATIVE MATERIALS, STRUCTURES AND TECHNOLOGIES (IMST 2017), 2017, 251
  • [8] Improving habitability in social housing through passive cooling: a case study in Mengibar (Ja′en, Spain)
    Delgado, MCarmen Guerrero
    Ramos, Jose Sanchez
    Amores, Teresa Rocio Palomo
    Medina, Daniel Castro
    Dominguez, Servando Alvarez
    SUSTAINABLE CITIES AND SOCIETY, 2022, 78
  • [9] The role of green roofs in climate change mitigation. A case study in Seville (Spain)
    Herrera-Gomez, Sergio S.
    Quevedo-Nolasco, Abel
    Perez-Urrestarazu, Luis
    BUILDING AND ENVIRONMENT, 2017, 123 : 575 - 584
  • [10] Building Automation for Passive Cooling of Office Buildings: A Case Study in Madrid
    Iannone, Francesco
    Franco, Natalia
    Parisi, Carmen
    Laera, Rossana
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE OF AR.TEC. (SCIENTIFIC SOCIETY OF ARCHITECTURAL ENGINEERING), VOL 2, COLLOQUI.AT.E 2024, 2025, 611 : 375 - 389