Research on error analysis and calibration method of 3-PUU parallel robot

被引:0
|
作者
Chen, Mingfang [1 ]
Liang, Hongjian [1 ]
He, Chaoyin [1 ]
Zhang, Yongxia [1 ]
Huang, Liang'en [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Mech & Elect Engn, 727 Jingming South Rd,Wujiaying St, Kunming 650500, Yunnan, Peoples R China
关键词
Parallel robot; error model; kinematic calibration; particle swarm optimization algorithm; pose accuracy;
D O I
10.1177/09544054241279470
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Kinematic calibration is necessary for the pose accuracy improvement of the parallel robots. However, difficulties occur in traditional calibration methods, such as exceeding a large number of error parameters and error accumulation. In this paper, a 3-PUU parallel robot is taken as the research object, and the closed-loop vector method and differential theory are employed to establish an error model. Through quantitative analysis of geometric parametric errors, redundant parameters within the calibration algorithm are meticulously eliminated. By treating the dominant error terms as optimization variables for the mechanism's parameters, the calibration problem is transformed into a nonlinear system optimization challenge, which effectively avoids the problem of multiple error parameters and accumulation of errors in the traditional method. Further, using the particle swarm algorithm to compute the minimum value of the objective function, one can obtain the actual structural parametric errors of the robot. These errors are then utilized to correct the kinematic model, enabling the calibration of the mechanism's parameters and ultimately enhancing operation accuracy. Lastly, simulation and experimental validation of the algorithm are carried out. The simulation results indicate that the end-effector position error converges to zero infinitely; and the experimental results indicate that the maximum error of the end-effector in the x, y, z directions and the maximum position error are reduced from 8.53, 11.67, 3.29, and 12.56 mm to 1.09, 1.32, 0.98, and 1.75 mm, respectively. The standard deviation of the position error is reduced from 2.43 to 0.32 mm. The mean error is reduced from 7.76 to 1.02 mm. To sum up, the operation accuracy and stability of the robot are greatly improved.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] GA-based architecture optimization of a 3-PUU parallel manipulator for stiffness performance
    Xu, Qingsong
    Li, Yangmin
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 153 - 153
  • [22] Kinematics analysis of a novel 2R1T 3-PUU parallel mechanism with multiple rotation centers
    Chen, Ziming
    Li, Meng
    Kong, Xianwen
    Zhao, Chen
    MECHANISM AND MACHINE THEORY, 2020, 152
  • [23] Optimal design of a 3-PUU parallel mechanism with 2R1T DOFs
    Wang, Liping
    Xu, Huayang
    Guan, Liwen
    MECHANISM AND MACHINE THEORY, 2017, 114 : 190 - 203
  • [24] A STUDY OF SHARP INCREASE PHENOMENON IN CONSTRAINT TORQUE ON THE UNIVERSAL JOINT OF 3-PUU PARALLEL MANIPULATOR
    Zhao, Jianwen
    Huang, Bo
    Hua, Dingguo
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2014, 29 (04): : 378 - 386
  • [25] Modeling and prototype experiment of a monolithic 3-PUU parallel micromanipulator with nano-scale accuracy
    Ghafarian, Mohammadali
    Shirinzadeh, Bijan
    Al-Jodah, Ammar
    Das, Tilok Kumar
    Wei, Weichen
    Shen, Tianyao
    SMART MATERIALS AND STRUCTURES, 2020, 29 (07)
  • [26] Tri-Axis force sensing and Controlling for a horizontally distributed 3-PUU parallel mechanism
    Ke, Jian-Dong
    Chiu, Yu-Jen
    Hsu, Hong-Chang
    Tsai, Jhy-Cherng
    Wang, Yu-Jen
    MEASUREMENT, 2025, 249
  • [27] Mobility analysis of a 3-PUU flexure-based manipulator based on screw theory and compliance matrix method
    Shunli Xiao
    Yangmin Li
    Qiaoling Meng
    International Journal of Precision Engineering and Manufacturing, 2013, 14 : 1345 - 1353
  • [28] Mobility Analysis of a 3-PUU Flexure-based Manipulator based on Screw Theory and Compliance Matrix Method
    Xiao, Shunli
    Li, Yangmin
    Meng, Qiaoling
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (08) : 1345 - 1353
  • [29] Trajectory control of a laparoscopic 3-PUU parallel manipulator based on neural network in SIMSCAPE SIMULINK environment
    Zidane, Iham F.
    Khattab, Yasmin
    El-Habrouk, Mohamed
    Rezeka, Sohair
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (12) : 9335 - 9363
  • [30] Dynamic Dexterity Evaluation of a 3-DOF 3-PUU Parallel Manipulator Based on Generalized Inertia Matrix
    Lu, Song
    Li, Yangmin
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2015, : 1506 - 1511