Background: Medications requiring refrigeration for stability are commonly used across hospitals. Temperature-sensitive medications may not have their temperature requirements maintained due to breaches in the cold chain, especially refrigerator failure. This is usually caused by malfunction of the refrigerator unit or by power outage. After multiple power outages at our institution involving refrigerators with temperature probes located in different areas of the refrigerator, we hypothesised that the fixed temperature probe may not accurately reflect the temperature of the medications themselves. Methods: We conducted simulations of power outages in a commonly used medication refrigerator, using additional temperature data loggers, placed on the refrigerator shelf and inside a cardboard box to replicate the temperature inside medication containers to determine if there was a difference in the time to breach cold chain conditions (>8 degrees C) and to return to appropriate refrigerated temperatures (<8 degrees C) when power was restored. Results: All data loggers took a longer time to breach cold chain conditions than the refrigerator probe (12.5 minutes vs 23-26 minutes) but took longer to return to acceptable temperature after power was restored (17.5 minutes vs 70.5-89 minutes). Conclusion: This exploratory research suggests that temperatures vary within a refrigerator depending on the type and location of probe and that medications within may take longer to breach cold chain conditions but also take longer to return to cold chain conditions compared with fixed refrigerator temperature probes. Further research is required to determine whether these variations occur across different sizes/brands of refrigerators and the effect on stability on refrigerated medications.
引用
收藏
页码:66 / 69
页数:4
相关论文
共 50 条
  • [21] Precision and accuracy of DFM soil water capacitance probes to measure temperature
    Mjanyelwa, Nokhwezi
    Bello, Zaid A.
    Greaves, Willnerie
    van Rensburg, Leon D.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2016, 125 : 125 - 128
  • [22] Perioperative temperature management: blowing hot and cold?
    Wythe, S.
    Richardson, H.
    ANAESTHESIA, 2014, 69 : 79 - 79
  • [23] Effects of cold-end temperature and heat load on the cooling characteristics of a pulse tube refrigerator
    Liu, Shaoshuai
    Jiang, Zhenhua
    Ding, Lei
    Zhu, Haifeng
    Qu, Xiaoping
    Wu, Yinong
    ENERGY SCIENCE & ENGINEERING, 2020, 8 (03): : 731 - 739
  • [24] Preparation and application of time temperature indicator in cold chain logistics
    Hu Z.
    Li Y.
    Cui Z.
    Huang B.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2023, 39 (22): : 246 - 257
  • [25] Evaluation of the dynamic behaviour of temperature sensors: application to the cold chain
    Manchego, Miguel G.
    Garrido-Izard, Miguel
    Correa, Eva C.
    Diezma, Belen
    Barreiro, Pilar
    IX CONGRESO IBERICO DE AGROINGENIERIA - LIBROS DE ACTAS, 2018, : 1081 - 1090
  • [26] TEMPERATURE INDICATOR TO MONITOR COLD CHAIN A BOON FOR TRANSFUSION MEDICINE
    Rao, P.
    VOX SANGUINIS, 2010, 99 : 122 - 122
  • [27] Outlier Detection in Cold-chain Logistics Temperature Monitoring
    Zhao, Weidong
    Dai, Weihui
    Zhou, Shangchen
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (03) : 65 - 68
  • [28] Analysis on Temperature Field of Refrigerated Car in Cold Chain Logistics
    Huang Xin
    Liu Guanghai
    Xie Ruhe
    2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL III, 2009, : 673 - +
  • [29] Applying back propagation network to cold chain temperature monitoring
    Chen, Kai-Ying
    Shaw, Yi-Cheng
    ADVANCED ENGINEERING INFORMATICS, 2011, 25 (01) : 11 - 22
  • [30] Temperature-dependent scaled frequency: Improved accuracy of multisensor capacitance probes
    Fares, A.
    Hamdhani, H.
    Jenkins, D. M.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2007, 71 (03) : 894 - 900