Microfluidic Lab-on-CMOS Packaging Using Wafer-Level Molding and 3D-Printed Interconnects

被引:0
|
作者
Dawes, Jacob [1 ]
Chou, Tzu-Hsuan [1 ]
Shen, Boyu [1 ,2 ]
Johnston, Matthew L. [1 ]
机构
[1] Oregon State Univ, Sch Elect Engn & Comp Sci, Corvallis, OR 97331 USA
[2] Texas Instruments Kilby Labs, Dallas, TX 75243 USA
关键词
Microfluidics; Electromagnetic compatibility; Integrated circuit interconnections; Integrated circuits; Passivation; Packaging; Surface topography; Flow cytometry; lab-on-chip; lab-on-CMOS; microfluidics; CHIP;
D O I
10.1109/TBCAS.2024.3419804
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Lab-on-a-chip (LoC) technologies continue to promise lower cost and more accessible platforms for performing biomedical testing in low-cost and disposable form factors. Lab-on-CMOS or lab-on-microchip methods extend this paradigm by merging passive LoC systems with active complementary metal-oxide semiconductor (CMOS) integrated circuits (IC) to enable front-end signal conditioning and digitization immediately next to sensors in fluid channels. However, integrating ICs with microfluidics remains a challenge due to size mismatch and geometric constraints, such as non-planar wirebonds or flip-chip approaches in conflict with planar microfluidics. In this work, we present a hybrid packaging solution for IC-enabled microfluidic sensor systems. Our approach uses a combination of wafer-level molding and direct-write 3D printed interconnects, which are compatible with post-fabrication of planar dielectric and microfluidic layers. In addition, high-resolution direct-write printing can be used to rapidly fabricate electrical interconnects at a scale compatible with IC packaging without the need for fixed tooling. Two demonstration sensor-in-package systems with integrated microfluidics are shown, including measurement of electrical impedance and optical scattering to detect and size particles flowing through microfluidic channels over or adjacent to CMOS sensor and read-out ICs. The approach enables fabrication of impedance measurement electrodes less than 1 mm from the readout IC, directly on package surface. As shown, direct fluid contact with the IC surface is prevented by passivation, but long-term this approach can also enable fluid access to IC-integrated electrodes or other top-level IC features, making it broadly enabling for lab-on-CMOS applications.
引用
收藏
页码:821 / 833
页数:13
相关论文
共 50 条
  • [31] Design and Architecture Definition for Advanced 3D Fan-Out Wafer-Level Packaging
    Bhangaonkar, Karan
    Sankarasubramanian, Santosh
    Journal of Microelectronics and Electronic Packaging, 2024, 21 (03): : 59 - 66
  • [32] Reaction engineering of through-chip via filling for wafer-level 3D packaging
    Barkey, D. P.
    Callahan, J.
    Keigler, A.
    Liu, Z.
    Ruff, A.
    Trezza, J.
    Wu, B.
    57TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 2007 PROCEEDINGS, 2007, : 638 - +
  • [33] Lab-in-a-pencil graphite: A 3D-printed microfluidic sensing platform for real-time measurement of antipsychotic clozapine level
    Senel, Mehmet
    Alachkar, Amal
    LAB ON A CHIP, 2021, 21 (02) : 405 - 411
  • [34] 3D EMBEDDED WAFER-LEVEL PACKAGING TECHNOLOGY DEVELOPMENT FOR SMART CARD SIP APPLICATION
    Pares, G.
    Bouvier, C.
    Saadaoui, M.
    Mazuir, J.
    Noiray, J.
    Martinschitz, K.
    Planchais, A.
    Simon, G.
    PROCEEDINGS OF THE 2012 IEEE 14TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, 2012, : 304 - 310
  • [35] Theoretical model and experiments of glass reflow process in TGV for 3D wafer-level packaging
    Kuang, Yunbin
    Xiao, Dingbang
    Zhou, Jian
    Li, Wenyin
    Hou, Zhanqiang
    Cui, Hongjuan
    Wu, Xuezhong
    2018 5TH IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS & SYSTEMS (INERTIAL 2018), 2018, : 85 - 88
  • [36] Wafer Level Packaging of MEMS and 3D Integration with CMOS for fabrication of Timing Microsystems
    Manier, Charles-Alix
    Zoschke, Kai
    Wilke, Martin
    Oppermann, Hermann
    Ruffieux, David
    Dalla Piazza, Silvio
    Suni, Tommi
    Dekker, James
    Allegato, Giorgio
    Lang, Klaus-Dieter
    2016 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2016,
  • [37] Fabrication of truly 3D microfluidic channel using 3D-printed soluble mold
    Kang, Kyunghun
    Oh, Sangwoo
    Yi, Hak
    Han, Seungoh
    Hwang, Yongha
    BIOMICROFLUIDICS, 2018, 12 (01):
  • [38] 3-D Numerical and Experimental Investigations on Compression Molding in Multichip Embedded Wafer Level Packaging
    Ji, Lin
    Sorono, Dexter Velez
    Chai, Tai Chong
    Zhang, Xiaowu
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2013, 3 (04): : 678 - 687
  • [39] A study on the dynamics of bacterial growth using biocompatible 3D-printed microfluidic device
    Ashish, Amlan
    Biswas, Poulomi
    Datta, Brateen
    Kanike, Chiranjeevi
    Atta, Arnab
    Dutta, Gorachand
    CHEMICAL ENGINEERING JOURNAL, 2024, 493
  • [40] Direct, one-step molding of 3D-printed structures for convenient fabrication of truly 3D PDMS microfluidic chips
    Ho Nam Chan
    Yangfan Chen
    Yiwei Shu
    Yin Chen
    Qian Tian
    Hongkai Wu
    Microfluidics and Nanofluidics, 2015, 19 : 9 - 18