Novel Quantitative Liver Steatosis Assessment Method With Ultrasound Harmonic Imaging

被引:0
|
作者
Gong, Ping [1 ]
Zhang, Jingke [1 ]
Huang, Chengwu [1 ]
Lok, U-Wai [1 ]
Tang, Shanshan [1 ]
Liu, Hui [1 ,2 ]
Deruiter, Ryan [1 ]
Peterson, Kendra [1 ]
Knoll, Kate [1 ]
Robinson, Kathryn [1 ]
Watt, Kymberly [3 ]
Callstrom, Matthew [1 ]
Chen, Shigao [1 ]
机构
[1] Mayo Clinic, Dept Radiol, Rochester, MN 55905 USA
[2] Fujian Med Univ, Affiliated Hosp 1, Dept Ultrasound, Fuzhou, Peoples R China
[3] Mayo Clin, Div Gastroenterol & Hepatol, Rochester, MN USA
关键词
quantitative evaluation of liver steatosis; ultrasound attenuation coefficient estimation; ultrasound harmonic imaging; HEPATIC STEATOSIS; DISEASE; DIAGNOSIS; AREAS;
D O I
10.1002/jum.16582
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Metabolic dysfunction-associated steatotic liver disease (MASLD) isthe most prevalent liver disorder in Western countries, with approximately 20%-30% of the MASLD patients progressing to severe stages. There is an urgentneed for noninvasive, cost-effective, widely accessible, and precise biomarkers toevaluate liver steatosis. This study aims to assess and compare the diagnostic per-formance of a novel reference frequency method-based ultrasound attenuationcoefficient estimation (ACE) in both fundamental (RFM-ACE-FI) and harmonic(RFM-ACE-HI) imaging for detecting and grading liver steatosis. Methods-An Institutional Review Board-approved prospective study was car-ried out between December 2018 and October 2022. A total number of 130 sub-jects were enrolled in the study. The correlation between RFM-ACE-HI valuesand magnetic resonance imaging proton density fat fraction (MRI-PDFF), aswell as between RFM-ACE-FI values and MRI-PDFF were calculated. The diag-nostic performance of RFM-ACE-FI and RFM-ACE-HI was evaluated usingreceiver operating characteristic (ROC) curve analysis, as compared to MRI-PDFF. The reproducibility of RFM-ACE-HI was assessed by interobserveragreement between two sonographers. Results-A strong correlation was observed between RFM-ACE-HI and MRI-PDFF, withR=0.88 (95% confidence interval [CI]: 0.83-0.92;P< .001),while the correlation between RFM-ACE-FI and MRI-PDFF wasR=0.65(95% CI: 0.50-0.76;P< .001). The area under the ROC (AUROC) curve forRFM-ACE-HI in staging liver steatosis grades of S >= 1 and S >= 2 was 0.97 (95%CI: 0.91-0.99;P< .001) and 0.98 (95% CI: 0.93-1.00;P< .001), respectively,and 0.76 (95% CI: 0.65-0.85) and 0.80 (95% CI: 0.70-0.88) for RFM-ACE-FI,respectively. Great reproducibility was achieved for RFM-ACE-HI, with an inter-observer agreement ofR=0.97 (95% CI: 0.94-0.99;P< .001). Conclusions-The novel RFM-ACE-HI method offered high liver steatosis diag-nostic accuracy and reproducibility, which has important clinical implications forearly disease intervention and treatment evaluation
引用
收藏
页码:77 / 85
页数:9
相关论文
共 50 条
  • [41] Development of unbiased quantitative method for the estimation of liver steatosis
    Bansal, M.
    Ormsby, A.
    Schultz, D.
    Jones, B.
    LABORATORY INVESTIGATION, 2007, 87 : 277A - 277A
  • [42] Development of unbiased quantitative method for the estimation of liver steatosis
    Bansal, M.
    Ormsby, A.
    Schultz, D.
    Jones, B.
    MODERN PATHOLOGY, 2007, 20 : 277A - 277A
  • [43] ASSESSMENT OF RESMETIROM- MEDIATED REDUCTIONS OF STEATOSIS AND CONCOMITANT BALLOONING UTILIZING QUANTITATIVE SECOND HARMONIC GENERATION IMAGING
    Tai, Dean
    Taub, Rebecca A.
    Ren, Ya-Yun
    Chng, Elaine Lay Khim
    Harrison, Stephen A.
    HEPATOLOGY, 2023, 78 : S766 - S767
  • [44] QUANTITAVE ULTRASOUND METHODS FOR THE ASSESSMENT OF LIVER STEATOSIS IN PATIENTS WITH ALD
    Plopeanu, Anca A.
    Popescu, Alina
    Cotrau, Radu
    Fofiu, Renata
    Burdan, Adrian
    Heredea, Darius
    Foncea, Camelia G.
    Bende, Felix
    Sirli, Roxana
    Sporea, Ioan
    GASTROENTEROLOGY, 2023, 164 (06) : S1559 - S1559
  • [45] The value of transabdominal ultrasound for assessment of the severity of liver steatosis as compared to liver biopsy
    Sporea, Ioan
    Sirli, Roxana
    Basa, Elena
    Cornianu, Maria
    Popescu, Alina
    Danila, Mirela
    Focsa, Mircea
    CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2009, 4 (04): : 490 - 495
  • [46] Harmonic interval delay imaging: A new ultrasound contrast method for imaging the blood pool volume in the liver
    Burns, PN
    Wilson, SR
    Simpson, DH
    Chin, CT
    Lai, X
    RADIOLOGY, 1998, 209P : 189 - 190
  • [47] Tissue attenuation imaging and tissue scatter imaging for quantitative ultrasound evaluation of hepatic steatosis
    Ronaszeki, Aladar D.
    Budai, Bettina K.
    Csongrady, Barbara
    Stollmayer, Robert
    Hagymasi, Krisztina
    Werling, Klara
    Fodor, Tamas
    Folhoffer, Aniko
    Kalina, Ildiko
    Gyori, Gabriella
    Maurovich-Horvat, Pal
    Kaposi, Pal N.
    MEDICINE, 2022, 101 (33) : E29708
  • [48] Fully automated quantitative assessment of hepatic steatosis in liver transplants
    Salvi, Massimo
    Molinaro, Luca
    Metovic, Jasna
    Patrono, Damiano
    Romagnoli, Renato
    Papotti, Mauro
    Molinari, Filippo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 123
  • [49] Second Harmonic Generation microscopy: a novel automated method for quantification of hepatic steatosis in chronic liver disease
    Goh, George B.
    Leow, Wei Qiang
    Liang, Shen
    Wan, Wei Keat
    Tai, Dean C.
    Lim, Kiat Hon
    Tan, Chee Kiat
    Chang, Jason P.
    HEPATOLOGY, 2016, 64 : 757A - 757A
  • [50] Wideband harmonic imaging: A novel contrast ultrasound imaging technique
    A. Bauer
    P. Hauff
    J. Lazenby
    P. von Behren
    M. Zomack
    M. Reinhardt
    R. Schlief
    European Radiology, 1999, 9 : S364 - S367