Ray Tracing of the New Multi-Modal X-ray Imaging Beamline PolyX at SOLARIS National Synchrotron Radiation Centre

被引:0
|
作者
Kosiorowski, Filip [1 ,2 ]
Wrobel, Pawel [1 ,2 ]
Kolodziej, Tomasz [1 ]
Sowa, Katarzyna M. [1 ]
Szczerbowska-Boruchowska, Magdalena [2 ]
Korecki, Pawel [1 ,3 ]
机构
[1] SOLARIS Natl Synchrotron Radiat Ctr, ul Czerwone Maki 98, PL-30392 Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, al Mickiewicza 30, PL-30059 Krakow, Poland
[3] Jagiellonian Univ, Inst Phys, ul Lojasiewicza 11, PL-30348 Krakow, Poland
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 17期
关键词
synchrotron beamline; ray-tracing simulations; Monte-Carlo simulations; OPTICS; SIMULATION;
D O I
10.3390/app14177486
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of the presented research is to evaluate the potential performance of a new bending magnet X-ray beamline-PolyX, designed for microimaging and microspectroscopy at the National Synchrotron Radiation Centre SOLARIS in Krakow. Due to the short beamline length (<15 m), PolyX uses compact polycapillary and single-bounce monocapillary optics for X-ray focusing in the 4-15 keV energy range. Polycapillary optics require a dedicated approach for an efficient simulation of X-ray propagation in multiple capillary channels. Therefore, the PolyX beamline was ray traced by combining XRT (XRayTracer) and polycap libraries. In addition, to estimate the X-ray fluorescence spectra excited by focused beams, Monte Carlo simulations were conducted using XMI-MSIM. All simulations were aimed to estimate the crucial X-ray beam properties, i.e., the flux, the spot size, and the energy spectrum, for monochromatic and polychromatic X-ray beams.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] MCX: a Synchrotron Radiation Beamline for X-ray Diffraction Line Profile Analysis
    Rebuffi, Luca
    Plaisier, Jasper R.
    Abdellatief, Mahmoud
    Lausi, Andrea
    Scardi, Paolo
    ZEITSCHRIFT FUR ANORGANISCHE UND ALLGEMEINE CHEMIE, 2014, 640 (15): : 3100 - 3106
  • [22] Vertical synchrotron radiation beamline for proximity X-ray lithography: Theoretical analysis
    Bukreeva, IN
    Kozhevnikov, IV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (02): : 244 - 258
  • [23] Novelty detection of foreign objects in food using multi-modal X-ray imaging
    Einarsdottir, Hildur
    Emerson, Monica Jane
    Clemmensen, Line Harder
    Scherer, Kai
    Willer, Konstantin
    Bech, Martin
    Larsen, Rasmus
    Ersboll, Bjarne Kjaer
    Pfeiffer, Franz
    FOOD CONTROL, 2016, 67 : 39 - 47
  • [24] X-ray multi-modal intrinsic-speckle-tracking
    Pavlov, Konstantin M.
    Paganin, David M.
    Li, Heyang
    Berujon, Sebastien
    Rouge-Labriet, Helene
    Brun, Emmanuel
    JOURNAL OF OPTICS, 2020, 22 (12)
  • [25] BEATS: BEAmline for synchrotron X-ray microTomography at SESAME
    Iori, Gianluca
    Alzu'bi, Mustafa
    Abbadi, Anas
    Al Momani, Yazeed
    Hasoneh, Abdel Rahman
    Van Vaerenbergh, Pierre
    Cudin, Ivan
    Marcos, Jordi
    Ahmad, Abdalla
    Mohammad, Anas
    Matalgah, Salman
    Foudeh, Ibrahim
    Al Najdawi, Mohammad
    Amro, Adel
    Rehman, Abid Ur
    Abugharbiyeh, Mohammad
    Khrais, Rami
    Aljadaa, Amro
    Nour, Mohammad
    Al Mohammad, Hussam
    Al Omari, Farouq
    Salama, Majeda
    Fuste, Maria Jose Garcia
    Reyes-Herrera, Juan
    Morawe, Christian
    Attal, Maher
    Kasaei, Samira
    Chrysostomou, Charalambos
    Kolodziej, Tomasz
    Boruchowski, Mateusz
    Nowak, Pawel
    Wiechecki, Jaroslaw
    Fatima, Anis
    Ghigo, Andrea
    Wawrzyniak, Adriana, I
    Lorentz, Kirsi
    Paolucci, Giorgio
    Lehner, Frank
    Krisch, Michael
    Stampanoni, Marco
    Rack, Alexander
    Kaprolat, Axel
    Lausi, Andrea
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 1358 - 1372
  • [26] The X-ray Fluorescence Microscopy Beamline at the Australian Synchrotron
    Paterson, D.
    de Jonge, M. D.
    Howard, D. L.
    Lewis, W.
    McKinlay, J.
    Starritt, A.
    Kusel, M.
    Ryan, C. G.
    Kirkham, R.
    Moorhead, G.
    Siddons, D. P.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 219 - 222
  • [27] X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
    Ossig, Christina
    Nietzold, Tara
    West, Bradley
    Bertoni, Mariana
    Falkenberg, Gerald
    Schroer, Christian G.
    Stuckelberger, Michael E.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (150):
  • [28] NEW METHODS FOR X-RAY IMAGING USING COMPACT SYNCHROTRON X-RAY SOURCES
    Feidenhans, R. K.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S126 - S127
  • [29] THE NAVAL RESEARCH LABORATORYS NEW HARD X-RAY BEAMLINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE
    KIRKLAND, JP
    ELAM, WT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1709 - 1711
  • [30] A new method to suppress high-order harmonics for a synchrotron radiation soft X-ray beamline
    郭志英
    邢海英
    洪才浩
    唐坤
    韩勇
    陈栋梁
    赵屹东
    Chinese Physics C, 2015, (04) : 101 - 103