Research on DC Component Suppression Method of Non-isolated Grid-Connected Inverter

被引:0
|
作者
Chen, Huige [1 ]
Wang, Shuangling [2 ]
机构
[1] Huanghe Sci & Technol Univ, Fac Engn, Zhengzhou, Peoples R China
[2] Zhengzhou Univ Econ & Business, Smart Mfg Coll, Zhengzhou, Peoples R China
关键词
DC component; Proportional integral resonance control; Grid-connected inverter; Non-isolated transformer; Moving average filtering; TRANSFORMERLESS; INJECTION;
D O I
10.1007/s42835-024-01940-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The zero drift occurring to the sampling conditioning circuit of the non-isolated grid-connected inverter will make the output develop a DC component, thus resulting in system failure and posing safety risks. According to the IEEE standard 1547-2003, the DC component injected into the grid side should be less than 0.5% of the rated current. In this paper, a moving average filter is proposed to extract the DC component of the three-phase AC output current. The filter has a very strong attenuation ability to the fundamental integer multiple harmonics, and can accurately extract the DC component. Then the proportional integral resonant controller (PIR) is used to control the system. The control system has sufficient bandwidth to avoid the stability problem caused by frequency offset. Through the above methods, the purpose of accurately suppressing the DC component in the non-isolated grid-connected inverter is realized. Also, a 50 kVA prototype is built in this study. The experimental results show that the moving average filter is advantageous over the conventional low-pass filter method in extracting the DC component, and the PIR controller used in the closed-loop control system outperforms the proportional integral and proportional resonant controllers. Under the strategy proposed in this study, the DC component is reduced to less than 0.5% of the rated current, and the THD of the grid-connected current falls below 5%.
引用
收藏
页码:5177 / 5185
页数:9
相关论文
共 50 条
  • [41] Research on LADRC of Grid-Connected Inverter Based on LCCL
    He, Guofeng
    Chen, Guanxu
    Dong, Yanfei
    Li, Guojiao
    Zhang, Wenjie
    ENERGIES, 2022, 15 (13)
  • [42] Research on grid-connected interleaved inverter with L filter
    Yao, Wenxi
    Lu, Zhengyu
    Long, Huang
    Li, Bin
    2013 1ST INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC 2013), 2013, : 87 - 92
  • [43] Research on MPPT Technology of the Photovoltaic Grid-connected Inverter
    Liu Jun
    Yuan You-chen
    2010 INTERNATIONAL CONFERENCE ON MANAGEMENT SCIENCE AND ENGINEERING (MSE 2010), VOL 4, 2010, : 344 - 347
  • [44] Research of three-loop control method of photovoltaic grid-connected inverter
    Li, Ming
    Yi, Ling-Zhi
    Peng, Han-Mei
    Deng, Dong
    Yao, Zhe-Zhi
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (19): : 46 - 50
  • [45] Research of three-loop Control Method Of PV Grid-connected Inverter
    Yi Lingzhi
    Li Ming
    Liu Xiang
    Deng Dong
    Yao Zhezhi
    2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 4281 - 4285
  • [46] Harmonic Resonance Suppression Strategy for LCL Grid-Connected Inverter in Weak Grid
    Gu, Yuanxin
    Yang, Ling
    Liu, Wendi
    Huang, Zehang
    Chen, Yiqian
    Chen, Sizhe
    Zhang, Yun
    2022 IEEE 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS, PESA, 2022,
  • [47] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137
  • [48] Cost-Effective DC Current Suppression for Single-Phase Grid-Connected PV Inverter
    Guo, Bin
    Su, Mei
    Sun, Yao
    Wang, Hui
    Li, Xing
    Liao, Yuefeng
    Lin, Jianheng
    Yang, Yongheng
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (02) : 1808 - 1823
  • [49] Research on the Control Method of the PV Grid-Connected Inverter under an Asymmetrical Power Grid Fault
    Tian, Shiji
    Lu, Min
    Wang, Ruikang
    Liu, Di'an
    ENERGIES, 2023, 16 (22)
  • [50] Conducted common-mode electromagnetic interference suppression in the AC and DC sides of a grid-connected inverter
    Liu, Yitao
    Mei, Zhaozhao
    Jiang, Shiqi
    Liang, Weihua
    IET POWER ELECTRONICS, 2020, 13 (13) : 2926 - 2934