Highly Sensitive Sensor for the Determination of Riboflavin Using Thionine Coated Cadmium Selenide Quantum Dots Modified Graphite Electrode

被引:3
|
作者
Kalaivani, Arumugam [1 ]
Suresh Babu, Rajendran [2 ]
Sriman Narayanan, Sangilimuthu [3 ]
机构
[1] Saveetha Engn Coll, Dept Chem, Chennai 602105, Tamil Nadu, India
[2] Ctr Fed Educ Tecnol Celso Suckow Fonseca, Lab Expt & Appl Phys, Ave Maracana Campus 229, BR-20271110 Rio De Janeiro, Brazil
[3] Univ Madras, Sch Chem Sci, Dept Analyt Chem, Guindy Campus, Chennai 600025, Tamil Nadu, India
来源
MICRO-SWITZERLAND | 2023年 / 3卷 / 03期
关键词
amperometry; CdSe QDs; cyclic voltammetry; modified electrode; riboflavin; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL-BEHAVIOR; GOLD NANOPARTICLES; FLUORESCENCE; FILM; FABRICATION; REDUCTION; BIOSENSOR; SAMPLES;
D O I
10.3390/micro3030048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the electrochemical non-enzymatic detection of Riboflavin (RF) was proposed based on its catalytic reduction in a Thionine-coated Cadmium Selenide Quantum dots (TH@CdSe QDs)-modified paraffin wax-impregnated graphite electrode (PIGE) that was prepared using a novel approach. The synthesized TH@CdSe QDs were confirmed by UV-Vis spectroscopy, Confocal Raman Microscopy and High Resolution Transmission Electron Microscopy (HRTEM) studies. The electrochemical response of the TH@CdSe QDs-modified PIGE was studied by cyclic voltammetry. The voltammetric response of RF at the TH@CdSe QDs-modified PIGE showed higher current than the bare PIGE. Under optimum conditions, the electrocatalytic reduction currents of RF was found to be linearly related to its concentration over the range of 1.6 x 10-7 M to 1.4 x 10-4 M with a detection limit of 53 x 10-9 M (S/N = 3). The TH@CdSe QDs-modified PIGE was utilized as an amperometric sensor for the detection of RF in flow systems was performed by carrying out hydrodynamic and chronoamperometric experiments. The TH@CdSe QDs-modified PIGE showed very good stability and a longer shelf life. The applicability of the fabricated electrode was justified by the quantification of RF in commercial tablets.
引用
收藏
页码:686 / 698
页数:13
相关论文
共 50 条
  • [41] Voltammetric determination of cadmium using magnetic graphite-epoxy composite electrode modified with magnetic nanoparticles
    dos Santos, Paula Mantovani
    Gorla, Felipe Augusto
    Wong, Ademar
    Corazza, Marcela Zanetti
    Sotomayor, Maria D. P. T.
    Tarley, Cesar Ricardo Teixeira
    TALANTA, 2025, 292
  • [42] Highly selective dopamine sensor based on graphene quantum dots self-assembled monolayers modified electrode
    Li, Yuhui
    Jiang, Yingying
    Mo, Tao
    Zhou, Haifeng
    Li, Yancai
    Li, Shunxing
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 767 : 84 - 90
  • [43] Graphite carbon nitride-modified screen-printed electrode as a highly sensitive and selective sensor for detection of amaranth
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Mohammad Reza
    Rayeni, Reza Abbasi
    Di Bartolomeo, Antonio
    Mohammadi, Sayed Zia
    FOOD AND CHEMICAL TOXICOLOGY, 2022, 163
  • [44] Highly sensitive and selective amperometric nitrite sensor based on electrochemically activated graphite modified screen printed carbon electrode
    Palanisamy, Selvakumar
    Karuppiah, Chelladurai
    Chen, Shen-Ming
    Periakaruppan, Prakash
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 727 : 34 - 38
  • [45] Low-cost and Highly Sensitive Sensor for Determining Atorvastatin Using PbTe Nanoparticles-Modified Graphite Screen-Printed Electrode
    Pourtaheri, Ehsan
    Taher, Mohammad Ali
    Ali, Gomaa A. M.
    Agarwal, Shilpi
    Gupta, Vinod Kumar
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (10): : 9622 - 9632
  • [46] Simultaneous Determination of Hydroquinone and Catechol using Carbon Glass Electrode Modified with Graphene Quantum Dots
    Tang, Jing
    Ma, Xiaoqing
    Liu, Jing
    Zheng, Shengbiao
    Wang, Jianfei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 11250 - 11262
  • [47] Highly sensitive fluorescent determination of sulfide using BSA-capped CdS quantum dots
    Na, Weidan
    Liu, Xiaotong
    Hu, Tianyu
    Su, Xingguang
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (02) : 1872 - 1877
  • [48] Flow-injection chemiluminescence analysis for sensitive determination of atenolol using cadmium sulfide quantum dots
    Khataee, Alireza
    Lotfi, Roya
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    Joo, Sang Woo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 157 : 88 - 95
  • [49] Nanostructured platform for the sensitive determination of paraoxon by using an electrode modified with a film of graphite-immobilized bismuth
    Stoytcheva, M.
    Zlatev, R.
    Montero, G.
    Velkova, Z.
    Gochev, V.
    MICROCHIMICA ACTA, 2017, 184 (08) : 2707 - 2714
  • [50] Nanostructured platform for the sensitive determination of paraoxon by using an electrode modified with a film of graphite-immobilized bismuth
    M. Stoytcheva
    R. Zlatev
    G. Montero
    Z. Velkova
    V. Gochev
    Microchimica Acta, 2017, 184 : 2707 - 2714