Continuous emission monitoring the trace Sr from simulant aerosol emission with LIPS

被引:0
|
作者
He, Hongyu [1 ]
Gao, Zhixing [1 ]
Tian, Heng [2 ]
He, Yun [1 ]
Liu, Juntao [2 ]
Wang, Yuanhang [1 ]
Liu, Zhiyi [2 ]
Guo, Bing [1 ]
机构
[1] China Inst Atom Energy, Dept Nucl Phys, Beijing 102413, Peoples R China
[2] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 100730, Gansu, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser-induced plasma spectrum; Continuous emission monitor (CEM); Strontium; Aerosol; AERODYNAMIC LENSES; LASER; SPECTROSCOPY; STRONTIUM; SAMPLES; SYSTEM; SR-90; COAL; LEAD;
D O I
10.1016/j.sab.2024.107015
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Continuous emission monitoring (CEM) of strontium in aerosols is of great significance for air pollution prevention and industrial facilities emission monitoring. Laser-induced plasma spectroscopy (LIPS, also LIBS) is a promising technology for direct and online monitoring aerosols because of the advantages of no sample preparation, rapid analysis, and online detection. An enhanced LIPS setup with high detection sensitivity and short detection cycles is integrated to meet the demand for continuous monitoring of trace element aerosols. The continuous monitoring of strontium in aerosols is introduced with an improved LIPS setup. The setup is calibrated and tested with different concentrations of strontium aerosols generated by aerosol generators. The enhanced LIPS setup can quantify 22 ng/m3 strontium in aerosol within 10 min. Based on experiments, a calibration curve for the strontium aerosol is established and the limit of detection (LOD) of the setup reaches 1.8 ng/ m3, which meets the need for continuous monitoring of trace elements.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] RELIABLE CONTINUOUS EMISSION MONITORING SYSTEMS FOR LEGAL STACK EMISSION SURVEILLANCE
    GREEN, R
    GLASS TECHNOLOGY, 1990, 31 (02): : 41 - 44
  • [12] EFFECT OF AEROSOL EMISSION OF INFERENCE OF TRACE GAS CONCENTRATIONS FROM LIMB RADIANCE DATA
    REMSBERG, EE
    RUSSELL, JM
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1974, 55 (05) : 488 - 488
  • [13] Status of multimetal continuous emission monitoring technologies
    French, NB
    Haas, W
    Priebe, S
    SPECTROSCOPY, 2000, 15 (07) : 24 - +
  • [14] Continuous emission monitoring Total Mercury analysis
    Zepeck, R
    Kasajanow, J
    ACID RAIN & ELECTRIC UTILITIES II, 1997, : 763 - 768
  • [15] AUTOMATIC EVALUATION OF CONTINUOUS EMISSION-MONITORING
    BUHNE, KW
    LANGER, U
    KOLN, WS
    STAUB REINHALTUNG DER LUFT, 1981, 41 (05): : 175 - 183
  • [16] Continuous emission monitoring system of power plant
    Lin, Heyun
    Wang, Feng
    Lu, Yuping
    Zhu, Weidong
    Gu, Chaochun
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2001, 25 (05): : 53 - 55
  • [17] LOCATING AND INSTALLING EQUIPMENT FOR CONTINUOUS EMISSION MONITORING
    FRANCZAK, DF
    PAPROCKI, TJ
    INSTRUMENTATION TECHNOLOGY, 1980, 27 (11): : 38 - 42
  • [18] CERTIFIED REFERENCE MATERIALS FOR CONTINUOUS EMISSION MONITORING
    HUGHES, EE
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (07): : 708 - 711
  • [19] A Study on the Comparison of Emission Factor Method and GEMS (Continuous Emission Monitoring System)
    Jang, Kee-Won
    Lee, Ju-Hyoung
    Jung, Sung-Woon
    Kang, Kyoung-Hee
    Hong, Ji-Hyung
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2009, 25 (05) : 410 - 419
  • [20] Summer 2009 wildfires in Portugal: Emission of trace gases and aerosol composition
    Alves, Celia
    Vicente, Ana
    Nunes, Teresa
    Goncalves, Catia
    Fernandes, Ana Patricia
    Mirante, Fatima
    Tarelho, Luis
    Sanchez de la Campa, Ana M.
    Querol, Xavier
    Caseiro, Alexandre
    Monteiro, Cristina
    Evtyugina, Margarita
    Pio, Casimiro
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (03) : 641 - 649