Development of a novel geometrically-parametric patient-specific finite element model for anterior cruciate ligament reconstruction

被引:0
|
作者
Khademi, Midiya [1 ]
Haghpanahi, Mohammad [2 ]
Razi, Mohammad [3 ]
Sharifnezhad, Ali [4 ]
Nikkhoo, Mohammad [1 ,5 ,6 ]
机构
[1] Islamic Azad Univ, Dept Biomed Engn, Sci & Res Branch, Tehran, Iran
[2] Iran Univ Sci & Technol, Dept Mech Engn, IUST, Tehran, Iran
[3] Iran Univ Med Sci, Orthoped Surg, IUMS, Tehran, Iran
[4] SSRI, Sport Sci Res Inst, Dept Sport Biomech & Technol, Tehran, Iran
[5] Chang Gung Univ, Sch Phys Therapy, Taoyuan, Taiwan
[6] Chang Gung Univ, Coll Med, Grad Inst Rehabil Sci, Taoyuan, Taiwan
来源
KNEE | 2024年 / 50卷
关键词
Anterior Cruciate Ligament; Reconstruction; Parametric 3D model; Gait analysis; Finite Element Method; KNEE; RETURN; SPORT; GAIT; ACL; OSTEOARTHRITIS; KINEMATICS; IMPACT; MOTION;
D O I
10.1016/j.knee.2024.07.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: A personalized model of the knee joint, with adjustable effective geometric parameters for the transplanted autograft diameter in Anterior Cruciate Ligament Reconstruction (ACLR) using the bone-patella-tendon-bone (BPTB) technique, has been developed. The model will assist researchers in understanding how different graft sizes impact a patient's recovery over time. Methods: The study involved selecting a group of individuals without knee injuries and one patient who had undergone knee surgery. Gait analysis was conducted on the control group and the patient at various time points. A 3D model of the knee joint was created using medical images of the patient. Forces and torques obtained from the gait analysis were applied to the model to perform finite element analysis. Results: The results of the finite element (FE) analysis, along with kinetic data from both groups, indicate that models with diameters of 7.5 mm and 12 mm improved joint motion during follow-up after ACLR. Additionally, a comparison of the stress applied to the ACL model revealed that a 12 mm autograft diameter showed a more favorable trend in patient recovery during the three follow-up intervals after ACL reconstruction surgery. Conclusion: The development of a personalized parametric model with adjustable geometric parameters in ACLR, such as the transplanted autograft diameter, as presented in this study, along with FE using the patient's kinetic data, allows for the examination and selection of an appropriate autograft diameter for Patella Tendon grafting. This can help reduce stress on the autograft and prevent damage to other knee joint tissues after ACLR. (c) 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:41 / 58
页数:18
相关论文
共 50 条
  • [21] FINITE ELEMENT ANALYSIS OF THE KNEE: DEVELOPMENT OF A FAILURE LOCUS FOR THE ANTERIOR CRUCIATE LIGAMENT
    Homyk, A.
    Orsi, A.
    Wibby, S.
    Yang, N. H.
    Hashemi, H. N.
    Canavan, P. K.
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 683 - 684
  • [22] Development of patient-specific finite element model for study of composite dental implants
    Gupta, Vivek
    Garg, Anshika
    Tewari, Nitesh
    Srivastav, Sukeshana
    Chanda, Arnab
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (02)
  • [23] How safe are partial squats after the anterior cruciate ligament reconstruction? A finite element analysis
    Kotiuk, V.
    Kostrub, O.
    Blonskyi, R.
    Podik, V.
    Sushchenko, L.
    [J]. KNEE, 2023, 43 : 192 - 199
  • [24] The first patient-specific finite element model of the rotational atherectomy
    Celi, S.
    Vaghetti, M.
    Palmieri, C.
    Kull, S.
    Marchi, F.
    Berti, S.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 347 - 347
  • [25] Patient-specific Finite Element Model of Coronary Artery Stenting
    Razaghi, Reza
    Karimi, Alireza
    Taheri, Ramezan Ali
    [J]. CURRENT PHARMACEUTICAL DESIGN, 2018, 24 (37) : 4492 - 4502
  • [26] Construction of finite element model and stress analysis of anterior cruciate ligament tibial insertion
    Dai, Can
    Yang, Liu
    Guo, Lin
    Wang, Fuyou
    Gou, Jingyue
    Deng, Zhilong
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2015, 31 (03) : 632 - 636
  • [27] Patient-specific finite element model of the hip muscles and bones
    Jolivet, Erwan
    Laredo, Jean-Denis
    Bonneau, Dominique
    Skalli, Wafa
    [J]. EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2009, 18 (01): : 117 - 129
  • [28] Effect of Menisci Presence on Anterior Cruciate Ligament Stress and Strain in a Finite Element Model
    Nyman, Edward, Jr.
    Ingels, Marcel L.
    Amerinatanzi, Amirhesam
    Summers, Rodney K.
    Hewett, Timothy E.
    Goel, Vijay K.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 888 - 888
  • [29] Validation of a finite element model of pediatric patient-specific mandible
    Zhao, LP
    Patel, PK
    Widera, GEO
    Harris, GF
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1831 - 1834
  • [30] A novel protection liner to improve graft-tunnel interaction following anterior cruciate ligament reconstruction: a finite element analysis
    Wang, Huizhi
    Zhang, Min
    Cheng, Cheng-Kung
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)