Experimental Investigation on Heat Transfer in Two-Phase Closed Thermosyphon Containing Non-Condensable Gas

被引:0
|
作者
Song, Binglin [1 ]
Meng, Guoying [1 ]
Huang, Wei [1 ]
Wang, Aiming [1 ]
Cheng, Xiaohan [1 ]
Yang, Jie [1 ]
机构
[1] China Univ Min & Technol Beijing, Sch Mechatron & Informat Engn, Beijing 100083, Peoples R China
关键词
two-phase closed thermosiphons; non-condensable gas; heat transfer performance; check valve; THERMAL PERFORMANCE; R134A;
D O I
10.3390/en17184693
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Given that two-phase closed thermosiphons (TPCT) are a prevalent and efficacious means of heat transfer. However, non-condensable gas (NCG) may potentially impact the heat transfer performance of the aforementioned devices. Nevertheless, the theoretical analysis of heat transfer in TPCT containing NCG is not fully comprehensive and therefore requires further supplementation by means of relevant experiments. This paper presents the development and experimental investigation of a theoretical heat transfer model for a TPCT containing NCG. The research encompasses the optimal fluid-filling ratio of R22 and R410a working fluid and the impact of NCG on heat transfer in the condenser section of TPCT. Experimental findings indicate that TPCT with R22 and R410a working fluids at a fluid-filling ratio of 60% and 50%, respectively, demonstrate excellent isotherm and heat transfer efficiency. The presence of NCG affects the condenser section heat transfer process of the vapor, leading to a 2 degrees C decrease in the average temperature of the condenser section of the TPCT (Tca). In comparison with the TPCT without NCG, it was observed that an increase in the mass of NCG from 0.0097 to 0.0197 mol resulted in a reduction in the effective length of the condenser section (La) and effective heat transfer rate (kappa) of R22 TPCT. The decrease in La was 75.1 mm, while the decrease in kappa was 15.02%. Furthermore, at the same NCG mass, the effective heat transfer rate of R410a TPCT is evidently superior to that of R22 TPCT. The NCG in the TPCT can be removed by using a check valve. Nevertheless, this will result in a reduction in the fluid-filling ratio of the TPCT. The temperature of the R410a TPCT containing 0.0197 mol NCG with a fluid-filling ratio of 50% is comparable to that observed in fluid-filling ratio of 40% after the NCG is exhausted.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] DESIGN AND EXPERIMENTAL ANALYSIS OF HEAT TRANSFER PERFORMANCE OF A TWO-PHASE CLOSED THERMOSYPHON SYSTEM
    M. S. Elmosbahi
    M. Hamdi
    M. Hazami
    Journal of Applied Mechanics and Technical Physics, 2023, 64 : 858 - 870
  • [22] Effect of non-condensable gas on startup of a loop thermosyphon
    He, Jiang
    Lin, Guiping
    Bai, Lizhan
    Miao, Jianyin
    Zhang, Hongxing
    Wang, Lu
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 72 : 184 - 194
  • [23] Experimental investigation of a stainless steel two-phase closed thermosyphon
    Lataoui, Zied
    Jemni, Abdelmajid
    APPLIED THERMAL ENGINEERING, 2017, 121 : 721 - 727
  • [24] Experimental investigation of the steam condensation heat transfer in the presence of non-condensable gas inside a vertical tube
    Ahn, Taehwan
    Kang, Jinhoon
    Nam, Sanggyun
    Jeong, Jae Jun
    Yun, Byongjo
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 161
  • [25] Experimental investigation of heat transfer characteristics of inclined aluminium two phase closed thermosyphon
    Mutalikdesai, Sachin V.
    Kate, Ajit M.
    Shinde, Tarang R.
    Kumar Gupta, Naveen
    Panchal, Hitesh
    Natrayan, L.
    Meena, Radhey Shyam
    Siddiqui, Md Irfanul Haque
    Patel, Anand
    Kumar, Abhinav
    KERNTECHNIK, 2023, 88 (06) : 632 - 641
  • [26] Heat transfer rate characteristics of two-phase closed thermosyphon heat exchanger
    Song, Wei
    Zheng, Changjin
    Yang, Jiaming
    RENEWABLE ENERGY, 2021, 177 : 397 - 410
  • [27] Effects of nanofluids on heat transfer characteristics of a two-phase closed thermosyphon
    Kamyar, A.
    Ong, K. S.
    Saidur, R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 65 : 610 - 618
  • [28] Heat transfer characteristics of titanium/water two-phase closed thermosyphon
    Qi Baojin
    Zhang Li
    Xu Hong
    Sun Yan
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (09) : 2174 - 2179
  • [29] Heat transfer in a two-phase closed thermosyphon working in Polar Regions
    Kuznetsov, G., V
    Ponomarev, K. O.
    Feoktistov, D., V
    Orlova, E. G.
    Lyulin, Yu, V
    Ouerdane, H.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 22
  • [30] Numerical analysis of convective heat transfer in a closed two-phase thermosyphon
    G. V. Kuznetsov
    M. A. Al-Ani
    M. A. Sheremet
    Journal of Engineering Thermophysics, 2011, 20 : 201 - 210