An international film dosimetry intercomparison to establish a multi-center audit framework

被引:0
|
作者
Beveridge, Sabeena [1 ]
Alves, Andrew [1 ]
Hussein, Mohammad [2 ]
Clark, Catharine H. [2 ,3 ,4 ]
Jornet, Nuria [5 ]
Viegas, Claudio C. B. [6 ]
Reniers, Brigitte [7 ]
Alvarez, Paola Elisa [8 ,9 ]
Azangwe, Godfrey [10 ]
Chelminski, Krzysztof [10 ]
Dimitriadis, Alexis [10 ]
Kazantsev, Pavel [10 ]
Swamidas, Jamema [10 ]
机构
[1] Australian Radiat Protect & Nucl Safety Agcy, Australian Clin Dosimetry Serv, 619 Lower Plenty Rd,, Yallambie, Vic, Australia
[2] Natl Phys Lab, Middlesex, England
[3] Univ Coll London Hosp, Radiotherapy Phys, London, England
[4] UCL, Dept Med Phys & Bioengn, London, England
[5] Hosp Santa Creu & Sant Pau, Serv Radiofis & Radioproteccio, Barcelona, Spain
[6] Natl Canc Inst, Rio De Janeiro, Brazil
[7] Univ Hasselt, CMK, NuTeC, Diepenbeek, Belgium
[8] Univ Texas MD Anderson Canc Ctr, IROC Houston Qual Assurance Ctr, Houston, TX USA
[9] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
[10] IAEA, Dept Nucl Sci & Applicat, A-1400 Vienna, Austria
关键词
audit; film dosimetry; quality assurance; FLAT-BED SCANNER; GAFCHROMIC EBT2; TEMPERATURE; ARTIFACTS;
D O I
10.1002/mp.17428
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In 2021, a Technical Meeting was hosted by the International Atomic Energy Agency (IAEA) where it was recommended that a standardized method for assessing the accuracy of film dose calculations should be established. Purpose: To design an audit that evaluates the accuracy of film dosimetry processes. To propose a framework for identifying out-of-tolerance results and to perform an international pilot study to test the audit design. Methods: Six members of an international Dosimetry Audit Network (DAN) developed an audit for radiochromic film dosimetry. A single host center provided the materials to each participating DAN member to conduct the audits. Materials included: (1) a set of two irradiated audit films (10 Sq: 10 cm x 10 cm, 15 Sq: 15 cm x 15 cm), (2) a reference calibration film set, and (3) a blank sheet of film. The participants were blinded to the dose and tasked with producing dose maps using their standard film dosimetry process. Average Region-Of-Interest (ROI: 2 cm x 2 cm) dose was measured from the dose maps and compared to the known dose. In the audit, all participants used their local scanning and software protocols. Film calibration was performed in two distinct ways: (1) using a calibration film set which was provided by the host center and (2) using a calibration film set which was locally irradiated. Several variations of the audit were also performed to examine how scanning and software processing can affect film dosimetry results. In the first variation of the audit (VariantA), a set of film scans was processed using five different software solutions. In the second variation of the audit (VariantB), all films were scanned on the same scanner and processed using two in-house software solutions. Results: Taking one film scan from each participant, the standard deviations (1 sigma) (SD) in the dose returned from the host calibration and returned from the local calibration were +/- 7.2% and +/- 6.5% respectively, with variations from -12.4% to 12.9% of the known dose. The larger dose variations in the data set were attributed to the corrections applied for variations in scanner brightness during processing and incorrectly assigned calibration doses. When the raw image data set was processed by an expert user of each software solution (VariantA) the SDs were +/- 2.7% and +/- 3.7% for in-house and vendor-based software, respectively. When the films were scanned on a single scanner and processed with the two in-house software solutions (VariantB) the results had a SD of +/- 2.3%. Conclusions:<bold> </bold>An audit has been designed and tested for radiotherapy film dosimetry at an international level. A framework for diagnosing issues within a film dosimetry process has been proposed that could be used to audit centers that use film as a dosimeter. Incorporating quality assurance throughout the film process is important in obtaining accurate and consistent film dosimetry. A better understanding of vendor-based software systems is necessary for users to process accurate and consistent film dosimetry.
引用
收藏
页码:9071 / 9087
页数:17
相关论文
共 50 条
  • [41] PFO closuRE and CryptogenIc StrokE (PRECISE) registry: a multi-center, international registry
    Jochen Wöhrle
    Bernard Bertrand
    Lars Søndergaard
    Mark Turner
    Werner Scholtz
    Réda Ibrahim
    François Bourlon
    Clinical Research in Cardiology, 2012, 101 : 787 - 793
  • [42] Allergic contact dermatitis in patients with frontal fibrosing alopecia: An international multi-center study
    Rudnicka, Lidia
    Rokni, Ghasem R.
    Lotti, Torello
    Wollina, Uwe
    Foelster-Holst, Regina
    Katsambas, Andreas
    Goren, Andy
    Di Lernia, Vito G.
    Rathod, Dipali
    Mirabi, Ali
    Ghaffari, Anousheh
    Rajan, Aswath
    Goldust, Mohamad
    DERMATOLOGIC THERAPY, 2020, 33 (04)
  • [43] UPDATED RESULTS FROM AN INTERNATIONAL MULTI-CENTER REGISTRY STUDY FOR ENDOSCOPIC ANTERIOR FUNDOPLICATION
    Lankarani, Ali
    Costamagna, Guido
    Boskoski, Ivo
    Nieto, Jose
    Lehman, Glen A.
    Kessler, William R.
    Selzer, Don J.
    Neuhaus, Horst
    Beyna, Torsten
    Mehta, Sheilendra
    Shah, Shinil
    Rey, Johannes
    Haber, Gregory B.
    Kiesslich, Ralf
    Starpoli, Anthony A.
    Abu Dayyeh, Barham K.
    Stavropoulos, Stavros N.
    Caca, Karel
    Chang, Kenneth J.
    Fanti, Lorella
    Testoni, Pier Alberto
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB282 - AB282
  • [44] A Multi-Center International Analysis of Lung Transplantation Outcomes in Patients With COVID-19
    Kashem, Mohammed Abul
    Loor, Gabriel
    Emtiazjoo, Amir
    Hartwig, Matthew
    Van Raemdonck, Dirk
    Calvelli, Hannah
    Pena, Andres Leon
    Salan-Gomez, Marcelo
    Zhao, Huaqing
    Warnick, Michael
    Villavicencio, Mauricio
    Ius, Fabio
    Ghadimi, Kamrouz
    Salman, Jawad
    Chandrashekaran, Satish
    Machuca, Tiago
    Sanchez, Pablo G.
    Subramaniam, Kathirvel
    Neyrinck, Arne
    Huddleston, Stephen
    Ceulemans, Laurens
    Osho, Asishana
    D'Silva, Ethan
    Ramamurthy, Uma
    Shaffer, Andrew
    Langer, Nathaniel
    Toyoda, Yoshiya
    CLINICAL TRANSPLANTATION, 2024, 38 (09)
  • [45] Marrow transplantation for sickle cell disease (SCD): Results of a multi-center international trial
    Walters, MC
    Patience, M
    Sanders, JE
    Matthews, DC
    Appelbaum, FR
    Storb, R
    Sullivan, KM
    BLOOD, 1995, 86 (10) : 1654 - 1654
  • [46] Anti-Fungal Prophylaxis in Pediatric Lung Transplantation - An International Multi-Center Survey
    Mead, L.
    Danziger-Isakov, L. A.
    Michaels, M. G.
    Goldfarb, S. B.
    Glanville, A. R.
    Benden, C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S291 - S291
  • [47] The severity of pediatric psoriasis correlates with risk of obesity: An international multi-center controlled assessment
    Mahoney, A.
    Benjamin, L.
    Heath, C.
    Callahan, S.
    Robinson, C.
    Menter, A.
    Cordoro, K. M.
    Girolomoni, G.
    Tom, W.
    Choon, S.
    Patel, S.
    Kwasny, M.
    Rademaker, A.
    Paller, A. S.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2011, 131 : S36 - S36
  • [48] CATHETER ABLATION OF ATRIAL FLUTTER IN THE YOUNG: INSIGHTS FROM AN INTERNATIONAL MULTI-CENTER REGISTRY
    Katic, Josip
    Badertscher, Patrick
    Mannhart, Diego
    Zeljkovic, Ivan
    Ammann, Peter
    Reichlin, Tobias
    Knecht, Sven
    Krisai, Philipp
    Kuhne, Michael
    Sticherling, Christian
    SWISS MEDICAL WEEKLY, 2024, 154 : 88S - 89S
  • [49] Premature menopause and autoimmune primary ovarian insufficiency in two international multi-center cohorts
    Vogt, Elinor Chelsom
    Real, Francisco Gomez
    Husebye, Eystein Sverre
    Bjornsdottir, Sigridur
    Benediktsdottir, Bryndis
    Bertelsen, Randi Jacobsen
    Demoly, Pascal
    Franklin, Karl Anders
    Gallastegui, Leire Sainz de Aja
    Gonzalez, Francisco Javier Callejas
    Heinrich, Joachim
    Holm, Mathias
    Jogi, Nils Oscar
    Leynaert, Benedicte
    Lindberg, Eva
    Malinovschi, Andrei
    Martinez-Moratalla, Jesus
    Mayoral, Raul Godoy
    Oudin, Anna
    Pereira-Vega, Antonio
    Semjen, Chantal Raherison
    Schlunssen, Vivi
    Triebner, Kai
    Oksnes, Marianne
    ENDOCRINE CONNECTIONS, 2022, 11 (05)
  • [50] Characterization of Complex Fractionated Atrial Electrograms by Sample Entropy: An International Multi-Center Study
    Cirugeda-Roldan, Eva
    Novak, Daniel
    Kremen, Vaclav
    Cuesta-Frau, David
    Keller, Matthias
    Luik, Armin
    Srutova, Martina
    ENTROPY, 2015, 17 (11): : 7493 - 7509