Measurement of transcranial Doppler insonation angles from three-dimensional reconstructions of CT angiography scans

被引:0
|
作者
Leotta, Daniel F. [1 ]
Anderson, Mark [2 ]
Straccia, Angela [3 ]
Zierler, R. Eugene [4 ]
Aliseda, Alberto [3 ]
Sheehan, Florence H. [5 ]
Sharma, Deepak [2 ]
机构
[1] Univ Washington, Appl Phys Lab, Box 355640, Seattle, WA 98105 USA
[2] Univ Washington, Dept Anesthesiol & Pain Med, Seattle, WA 98195 USA
[3] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[4] Univ Washington, Dept Surg, Div Vasc Surg, Seattle, WA 98195 USA
[5] Univ Washington, Dept Med, Div Cardiol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
Transcranial Doppler; TCD; Doppler angle; Computed tomography angiography; Vasospasm; SONOGRAPHY; VELOCITY; ARTERIES;
D O I
10.1007/s10877-024-01187-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Blood velocities measured by Transcranial Doppler (TCD) are dependent on the angle between the incident ultrasound beam and the direction of blood flow (known as the Doppler angle). However, when TCD examinations are performed without imaging the Doppler angle for each vessel segment is not known. We have measured Doppler angles in the basal cerebral arteries examined with TCD using three-dimensional (3D) vessel models generated from computed tomography angiography (CTA) scans. This approach produces angle statistics that are not accessible during non-imaging TCD studies. We created 3D models of the basal cerebral arteries for 24 vasospasm patients. Standard acoustic windows were mapped to the specific anatomy of each patient. Virtual ultrasound transmit beams were generated that originated from the acoustic window and intersected the centerline of each arterial segment. Doppler angle measurements were calculated and compiled for each vessel segment. Doppler angles were smallest for the middle cerebral artery M1 segment (median 24.6 degrees) and ophthalmic artery (median 25.0 degrees), and largest for the anterior cerebral artery A2 segment (median 76.4 degrees) and posterior cerebral artery P2 segment (median 75.8 degrees). The ophthalmic artery had the highest proportion of Doppler angles that were less than 60 degrees (99%) while the anterior cerebral artery A2 segment had the lowest proportion of Doppler angles that were less than 60 degrees (10%). These angle measurements indicate the expected deviation between measured and true velocities in the cerebral arteries, highlighting specific segments that may be prone to underestimation of velocity.
引用
收藏
页码:1101 / 1115
页数:15
相关论文
共 50 条
  • [31] Three-dimensional power Doppler angiography of the cardiovascular system of a pseudoacardiac fetus
    Mivelaz, Y.
    Brassard, M.
    Audibert, F.
    Fouron, J. C.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (03) : 387 - 389
  • [32] Preoperative assessment of endometrial carcinoma by three-dimensional power Doppler angiography
    Saarelainen, S. K.
    Vuento, M. H.
    Kirkinen, P.
    Maenpaa, J. U.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (04) : 466 - 472
  • [33] Three-dimensional ultrasonic angiography using power-mode Doppler
    Department of Electrical Engineering, Seattle, WA, United States
    不详
    不详
    ULTRASOUND MED. BIOL., 3 (277-286):
  • [34] Three-Dimensional Power Doppler Angiography of Cyclic Ovarian Blood Flow
    Hope, Joanie Mayer
    Long, Kara
    Kudla, Marek
    Arslan, Alan
    Tsymbal, Tatiana
    Strok, Irina
    Timor-Tritsch, Ilan E.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (08) : 1043 - 1052
  • [35] Automated computation of femoral angles in dogs from three-dimensional computed tomography reconstructions: Comparison with manual techniques
    Longo, F.
    Nicetto, T.
    Banzato, T.
    Savio, G.
    Drigo, M.
    Meneghello, R.
    Concheri, G.
    Isola, M.
    VETERINARY JOURNAL, 2018, 232 : 6 - 12
  • [36] Three-dimensional helical CT angiography of skull base meningiomas
    Tsuchiya, K
    Hachiya, J
    Mizutani, Y
    Yoshino, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (05) : 933 - 936
  • [37] Three-dimensional spiral CT angiography in the detection of cerebral aneurysm
    Strayle-Batra, M
    Skalej, M
    Wakhloo, AK
    Ernemann, U
    Klier, R
    Voigt, K
    ACTA RADIOLOGICA, 1998, 39 (03) : 233 - 238
  • [38] Three-dimensional spiral CT angiography in renal artery stenosis
    Inoue, T
    Asahi, S
    Tanaka, K
    Sakai, Y
    Morooka, S
    JOURNAL OF CARDIOVASCULAR DIAGNOSIS AND PROCEDURES, 1998, 15 (01): : 55 - 58
  • [39] Three-Dimensional Reconstruction of Monochamus alternatus Galleries Using CT Scans
    Yang, Huawei
    Gao, Shangkun
    Wang, Jinxing
    Li, Wen
    Hou, Qingfeng
    Qiu, Jianfeng
    INSECTS, 2022, 13 (08)
  • [40] Three-dimensional reconstructions of carotid bifurcation from CT images: Evaluation of different rendering methods
    Tarjan, Z
    Mucelli, FP
    Frezza, F
    Mucelli, RP
    EUROPEAN RADIOLOGY, 1996, 6 (03) : 326 - 333