Measurement of transcranial Doppler insonation angles from three-dimensional reconstructions of CT angiography scans

被引:0
|
作者
Leotta, Daniel F. [1 ]
Anderson, Mark [2 ]
Straccia, Angela [3 ]
Zierler, R. Eugene [4 ]
Aliseda, Alberto [3 ]
Sheehan, Florence H. [5 ]
Sharma, Deepak [2 ]
机构
[1] Univ Washington, Appl Phys Lab, Box 355640, Seattle, WA 98105 USA
[2] Univ Washington, Dept Anesthesiol & Pain Med, Seattle, WA 98195 USA
[3] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[4] Univ Washington, Dept Surg, Div Vasc Surg, Seattle, WA 98195 USA
[5] Univ Washington, Dept Med, Div Cardiol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
Transcranial Doppler; TCD; Doppler angle; Computed tomography angiography; Vasospasm; SONOGRAPHY; VELOCITY; ARTERIES;
D O I
10.1007/s10877-024-01187-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Blood velocities measured by Transcranial Doppler (TCD) are dependent on the angle between the incident ultrasound beam and the direction of blood flow (known as the Doppler angle). However, when TCD examinations are performed without imaging the Doppler angle for each vessel segment is not known. We have measured Doppler angles in the basal cerebral arteries examined with TCD using three-dimensional (3D) vessel models generated from computed tomography angiography (CTA) scans. This approach produces angle statistics that are not accessible during non-imaging TCD studies. We created 3D models of the basal cerebral arteries for 24 vasospasm patients. Standard acoustic windows were mapped to the specific anatomy of each patient. Virtual ultrasound transmit beams were generated that originated from the acoustic window and intersected the centerline of each arterial segment. Doppler angle measurements were calculated and compiled for each vessel segment. Doppler angles were smallest for the middle cerebral artery M1 segment (median 24.6 degrees) and ophthalmic artery (median 25.0 degrees), and largest for the anterior cerebral artery A2 segment (median 76.4 degrees) and posterior cerebral artery P2 segment (median 75.8 degrees). The ophthalmic artery had the highest proportion of Doppler angles that were less than 60 degrees (99%) while the anterior cerebral artery A2 segment had the lowest proportion of Doppler angles that were less than 60 degrees (10%). These angle measurements indicate the expected deviation between measured and true velocities in the cerebral arteries, highlighting specific segments that may be prone to underestimation of velocity.
引用
收藏
页码:1101 / 1115
页数:15
相关论文
共 50 条
  • [1] Pubic Symphyseal Age Estimation from Three-Dimensional Reconstructions of Pelvic CT Scans of Live Individuals
    Wink, Alexandra E.
    JOURNAL OF FORENSIC SCIENCES, 2014, 59 (03) : 696 - 702
  • [2] Three-dimensional power Doppler angiography
    Guo, ZY
    Durand, LG
    Holdsworth, D
    Fenster, A
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997, 1997, 3033 : 215 - 224
  • [3] Calculation of the aortic arch angles from three-dimensional reconstructions of computed tomography scans: Comparison between an automated program and visual assessment
    Gaudric, Julien
    Teresa Politi, Maria
    Manuel Fernandez, Juan
    Carre, Emmanuelle
    Capurro, Claudia
    Fullana, Jose Maria
    COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 114
  • [4] Three-dimensional transcranial color Doppler US techniques
    Saouaf, R
    Longmaid, HE
    Suojanen, JN
    RADIOLOGY, 1996, 201 : 1133 - 1133
  • [5] Celiac artery aneurysm: Diagnosis by color Doppler sonography and three-dimensional CT angiography
    Soudack, M
    Gaitini, D
    Ofer, A
    JOURNAL OF CLINICAL ULTRASOUND, 1999, 27 (01) : 49 - 51
  • [6] COMPUTERIZED 3-DIMENSIONAL RECONSTRUCTIONS FROM CT SCANS
    HIRSCH, BE
    ROBERTS, D
    UDUPA, KJ
    ANATOMICAL RECORD, 1983, 205 (03): : A83 - A84
  • [7] Accuracy assessment of CT angiography for three-dimensional measurement of intracranial aneurysm geometry
    Sato, Y
    Quets, JP
    Sickels, WJ
    Traynalis, VC
    Loftus, CM
    Follett, KA
    RADIOLOGY, 1997, 205 : 163 - 163
  • [8] Three-dimensional measurement using silhouette images from random angles
    Three-dimensional measurement using silhouette images from random angles
    Kawasue, K. (kawasue@computer.org), 2005, Japan Society of Mechanical Engineers (71):
  • [9] Three-dimensional echo-enhanced transcranial Doppler ultrasound
    Bauer, A
    Bogdahn, U
    Haase, A
    Schlief, R
    RADIOLOGE, 1998, 38 (05): : 394 - 398
  • [10] Three-dimensional analysis of ground glass opacities from helical CT scans
    Reeves, AP
    Kostis, WJ
    Yankelevitz, DF
    Henschke, CI
    RADIOLOGY, 2000, 217 : 384 - 384