Long-term clinical results and patient satisfaction of a metaphyseal-engaging anatomic cementless femoral component in total hip arthroplasty

被引:0
|
作者
Kim, Young-Hoo [1 ]
Park, Jang-Won [2 ]
Jang, Young-Soo [1 ]
Kim, Eun-Jung [1 ]
机构
[1] SeoNam Hosp, Joint Replacement Ctr, Seoul Metropolitan Govt, 20 Shinjoung Ipen 1ro, Seoul 08049, South Korea
[2] Ewha Womans Univ, Seoul Hosp, Dept Orthoped Surg, Seoul, South Korea
关键词
Long-term; Metaphyseal-engaging; Cementless; Femoral component; Clinical results; Patient satisfaction; Survival rate; 15-YEAR FOLLOW-UP; PATIENTS YOUNGER; REPLACEMENT; AGE; PRESERVATION; ARTHRITIS; OUTCOMES; 10-YEAR; THA;
D O I
10.1007/s00264-024-06322-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose There is relatively little information on the long-term clinical results of patients aged < 50 years with a contemporary total hip arthroplasty (THA), although a high rate of revision is projected for this group. Therefore, the purpose of this study was to evaluate the long-term results (a minimum of 21 years) of a metaphyseal-engaging anatomic cementless total hip prosthesis in patients aged < 50 years at the time of their THA. Methods This study included 360 patients (498 hips), specifically 212 men and 148 women. The mean age of the patients at the time of their THA was 45.8 +/- 8.1 years. The predominant diagnosis was osteonecrosis (56%). Demographic data, the Harris hip score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the University of California, Los Angeles (UCLA) activity score were recorded. Radiographic evaluation and dual-energy X-ray absorptiometry (DEXA) scanning were used to evaluate implant fixation, bone remodelling, and osteolysis. The mean follow-up was 25.2 year (range 21-28 years). Results At the latest follow-up, the mean Harris hip, WOMAC, and UCLA activity scores were 93, 10, and 6.7 points, respectively. No patients had thigh pain. All hips had osseous integration of the acetabular and femoral components. No patient had grade 3 stress shielding. The 28-year survival rate was 98.2% (95% confidence interval [CI] 95-100%) for the acetabular components and 98.8% (95% CI 95-100%) for the femoral components. Overall, 90% of the patients were satisfied with the THA results. Conclusion The results suggest that a metaphyseal-engaging anatomic cementless femoral stem with alumina-on-alumina ceramic articulation provide outstanding long-term fixation and substantial pain relief well into the 3rd decade after surgery. Furthermore, there was no alumina ceramic fracture or osteolysis. Moreover, approximately 90% of the patients were satisfied with the results of their THA.
引用
收藏
页码:3127 / 3137
页数:11
相关论文
共 50 条
  • [11] Long-term results of cementless anatomic total hip replacement in dysplastic hips.
    Bruzzone M.
    La Russa M.
    Garzaro G.
    Ferro A.
    Rossi P.
    Castoldi F.
    Rossi R.
    MUSCULOSKELETAL SURGERY, 2009, 93 (3) : 131 - 136
  • [12] Long-Term Outcomes of Ultra-Short Metaphyseal-Fitting Anatomic Cementless Femoral Stem in Total Hip Arthroplasty With Ceramic-on-Ceramic Articulation for Young Patients
    Kim, Young-Hoo
    Park, Jang-Won
    JOURNAL OF ARTHROPLASTY, 2019, 34 (10): : 2427 - 2433
  • [13] Fatigue failure of the femoral component of a cementless total hip arthroplasty
    Morgan-Hough, CVJ
    Tavakkolizadeh, A
    Purkayastha, S
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 658 - 660
  • [14] Tapered design for the cementless total hip arthroplasty femoral component
    Mallory, TH
    Head, WC
    Lombardi, AV
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (344) : 172 - 178
  • [15] Isoelastic femoral component in primary cementless total hip arthroplasty
    Salaman M. Ali
    A. Kumar
    International Orthopaedics, 2002, 26 : 243 - 246
  • [16] Isoelastic femoral component in primary cementless total hip arthroplasty
    Ali, MS
    Kumar, A
    INTERNATIONAL ORTHOPAEDICS, 2002, 26 (04) : 243 - 246
  • [17] Long-Term results of total Hip Arthroplasty performed using a cementless expansive Acetabular Cup and Spotorno Femoral Stem
    Carkci, Engin
    Polat, Ayse Esin
    Ozturkmen, Yusuf
    Tuzuner, Tolga
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (01) : 52 - 58
  • [18] Long-term results of cementless total hip arthroplasty using the Lord prosthesis in Japan
    Tomonori Baba
    Katsuo Shitoto
    European Journal of Orthopaedic Surgery & Traumatology, 2009, 19 : 163 - 166
  • [19] Long-term results of cementless total hip arthroplasty using the Lord prosthesis in Japan
    Baba, Tomonori
    Shitoto, Katsuo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2009, 19 (03): : 163 - 166
  • [20] FIXATION OF THE MODULAR TOTAL HIP FEMORAL COMPONENT IN CEMENTLESS TOTAL HIP-ARTHROPLASTY
    WHITESIDE, LA
    ARIMA, J
    WHITE, SE
    BRANAM, L
    MCCARTHY, DS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 184 - 190