A Parametric Study on the Flexural Capacity of Cold-Formed Steel Stacked Built-up Sections

被引:0
|
作者
Rezaeian, Hooman [1 ]
Andarini, Rhonita [2 ]
Bock, Marina [3 ]
Yekrangnia, Mohammad [4 ]
机构
[1] Howick Ltd, Auckland, New Zealand
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
[3] Aston Univ, Dept Civil Engn, Birmingham B4 7ET, England
[4] Shahid Rajaee Teacher Training Univ, Dept Civil Engn, Tehran, Iran
关键词
Cold-formed steel; Stacked built-up section; Flexural capacity; Direct strength method; Parametric study; BEHAVIOR; CHANNELS; DESIGN; BEAM;
D O I
10.1007/s13296-024-00895-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an exploratory parametric study on the flexural capacity of an innovative cold-formed steel (CFS) stacked built-up beam section. The built-up section consists of lipped channel sections mounting vertically and screwed together through their lips and webs. Using the Direct Strength Method (DSM), a parametric study of this section is presented. The accuracy of this method is proven by comparing the results of the experiments with the modelling. Different configurations are studied, including sections compromising two, three, four and five channel sections, with thicknesses ranging from 1 to 3 mm. Four different steel grades are considered. The open flange of the built-up sections is covered by a CFS steel sheet cap to make a closed box beam. The effect of different thicknesses of the cap on the flexural capacity is also studied. The impact of the section configuration and thickness is understood to be more pronounced on the flexural capacity.
引用
收藏
页码:1142 / 1153
页数:12
相关论文
共 50 条
  • [31] Analysis of the bearing capacity of cold-formed steel quadruple limbs built-up members under flexural loading
    Zhao, Yi-Jie
    Du, Zhao-Yu
    Zhang, Qi-Lin
    Zhang, Q.-L. (zhangqilin@tongji.edu.cn), 1600, Hunan University (39): : 28 - 34
  • [32] Experimental study of the cross-sectional capacity of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    THIN-WALLED STRUCTURES, 2020, 155
  • [33] Study on the flexural behavior of corroded built-up cold-formed thin-walled steel beams
    Zhang, Zongxing
    Xu, Shanhua
    Li, Han
    Li, Rou
    Nie, Biao
    STEEL AND COMPOSITE STRUCTURES, 2020, 37 (03): : 353 - 369
  • [34] Design of cold-formed steel built-up sections with web perforations subjected to bending
    Wang, Liping
    Young, Ben
    THIN-WALLED STRUCTURES, 2017, 120 : 458 - 469
  • [35] Web crippling design of cold-formed steel built-up I-sections
    He, Jun
    Young, Ben
    ENGINEERING STRUCTURES, 2022, 252
  • [36] Simplified design method of cold-formed steel columns with built-up box sections
    Zhou, Xuhong
    Xiang, Yi
    Shi, Yu
    Xu, Lei
    Zou, Yuxuan
    ENGINEERING STRUCTURES, 2021, 228
  • [37] Behavior of Cold-Formed Steel Built-Up Sections with Intermediate Stiffeners under Bending. II: Parametric Study and Design
    Wang, Liping
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [38] Experimental and Numerical Investigation on Flexural Behavior of Novel Unsymmetrical Cold-Formed Steel Built-Up Stiffened Box Sections
    Dai, Yecheng
    Raftery, Gary M.
    Roy, Krishanu
    Hajirasouliha, Iman
    Fang, Zhiyuan
    Chen, Boshan
    Lim, James B. P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2025, 151 (02)
  • [39] COMPRESSION TESTS OF COLD-FORMED STEEL BUILT-UP CLOSED SECTIONS WITH WEB STIFFENERS
    Zhang, Jia-Hui
    Young, Ben
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [40] Beam-Column Tests of Cold-Formed Steel Built-Up Closed Sections
    Li, Qiu-Yun
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (04)