Effects of Neutron Irradiation on Photomultiplier Tubes and Their Power Supplies

被引:1
|
作者
Preziosi, Enrico [1 ,2 ]
Addis, Antonio [3 ]
Andreani, Carla [1 ,2 ,4 ]
Cazzaniga, Carlo [5 ]
Fazi, Laura [1 ,2 ]
Frost, Christopher D. [5 ]
Kastriotou, Maria [5 ]
Levi, Giuseppe [6 ,7 ]
Picozza, Piergiorgio [1 ,2 ]
Pietrosanti, Virginia [1 ,2 ]
Romanelli, Giovanni [1 ,2 ]
Tardocchi, Marco [8 ]
Ursi, Alessandro [9 ]
Virgilli, Enrico [3 ]
Senesi, Roberto [1 ,2 ,10 ]
机构
[1] Univ Roma Tor Vergata, Dept Phys, I-00133 Rome, Italy
[2] Univ Roma Tor Vergata, NAST Ctr, I-00133 Rome, Italy
[3] Natl Inst Astrophys INAF, Astrophys & Space Sci Observ OAS, I-4012 Bologna, Italy
[4] Natl Res Council CNR, IPCB, I-80125 Naples, Italy
[5] UKRI STFC, Rutherford Appleton Lab, ISIS Facil, Didcot OX11 0QX, England
[6] Univ Bologna, Dept Phys & Astron, I-40126 Bologna, Italy
[7] INFN Bologna, I-40127 Bologna, Italy
[8] Natl Res Council Italy, Inst Plasma Sci & Technol, I-00185 Milan, Italy
[9] Natl Inst Astrophys INAF IAPS, Rome, Italy
[10] Natl Res Council CNR, ISM, I-00133 Rome, Italy
关键词
Neutrons; Power supplies; Detectors; Photomultipliers; Electron tubes; Scintillators; Particle beams; neutron detectors; neutron radiation effects; photomultipliers; radiation effects; radiation effects in devices; GROUND-LEVEL; COMPONENTS;
D O I
10.1109/TNS.2023.3309911
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the context of the Gamma-Flash program, whose objective is to investigate the emission of high-energy gamma rays and neutrons during thunderstorms, a neutron detection system, based on scintillators coupled to photomultiplier tubes (PMTs), has been developed. The neutrons emitted are generated by photoproduction reactions in the atmosphere, and they have a wide range of energies, from MeV down to meV. In this work, the effects of neutron irradiation on PMTs and their power supply are investigated to assess and quantify the effects of irradiation on dark-count rate and during data acquisition. The detection system was irradiated at the ChipIr beamline at ISIS Neutron and Muon Source, Didcot, U.K. During the irradiation of power supplies, an increase in dark-count rate has been observed, whose magnitude depends on the output voltages and the experimental parameters. In the specific case of our experiment, the dark-count rate went from an average value of 0 to 40 and 120 counts per second (counts/s) at the operating voltage of 1800 and 1900 V, respectively. Even more evident are the effects during the irradiation of the PMTs; in this case, the dark-count rate reaches about 4000 counts/s, high enough to hamper the measurements. These effects, despite their relevance to data acquisition and detector performance, do not produce long-term consequences on the electronic components. Beyond the Gamma-Flash program, this research is relevant, because the use of PMTs is common in many areas of scientific research and radiation detection applications. Our results highlight the need for great care in the interpretation of results in applications where PMTs and their power supplies may be exposed to high radiation fluxes. A proper design of the experiment or shielding strategies could prevent such unwanted behavior in data acquisition.
引用
收藏
页码:2003 / 2011
页数:9
相关论文
共 50 条
  • [31] TRANSIENT NOISE IN PHOTOMULTIPLIER TUBES
    CLEMESHA, BR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1977, 10 (08): : 814 - 816
  • [32] Photomultiplier tubes in the MiniBooNE experiment
    Brice, S. J.
    Bugel, L.
    Conrad, J. M.
    Fleming, B.
    Gladstone, L.
    Hawker, E.
    Killewald, P.
    May, J.
    McKenney, S.
    Nienaber, P.
    Roe, B.
    Sandberg, V.
    Smith, D.
    Wysocki, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (01): : 97 - 109
  • [33] PHOTOMULTIPLIER TUBES FOR SATELLITE INSTRUMENTATION
    SCHLUETER, P
    APPLIED OPTICS, 1967, 6 (02) : 239 - +
  • [34] Improving the performance of photomultiplier tubes
    Harmer, S. W.
    Townsend, P. D.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (41)
  • [35] WINDOWLESS SEAL FOR PHOTOMULTIPLIER TUBES
    DAVIS, P
    GINGLE, AR
    KNASEL, TM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (07): : 960 - 960
  • [36] GAIN VARIATION OF PHOTOMULTIPLIER TUBES
    CALDWELL, RL
    TURNER, SE
    NUCLEONICS, 1954, 12 (12): : 47 - 48
  • [37] High Voltage Power Supply With High Output Current and Low Power Consumption for Photomultiplier Tubes
    Cunha, Jose Paulo V. S.
    Begalli, Marcia
    Bellar, Maria Dias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (02) : 281 - 288
  • [38] EFFECTS OF HIGH ENERGY RADIATIONS ON NOISE PULSES FROM PHOTOMULTIPLIER TUBES
    JERDE, RL
    PETERSON, LE
    STEIN, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (10): : 1387 - +
  • [39] STUDY OF PHOTOMULTIPLIER ANODE-CURRENT VARIATION WITH PULSE GAMMA-NEUTRON IRRADIATION
    MAKEEV, SN
    PETROV, VA
    POPOV, VG
    SMELYANSKII, IM
    TRUBITSYN, NM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (06) : 1386 - 1388
  • [40] Performance of photomultiplier tubes for cryogenic applications
    Carbonara, Francesco
    Cocco, Alfredo G.
    Fiorillo, Giuliana
    Gallo, Valentina S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 271 - 275