Noise suppression in photon-counting computed tomography using unsupervised Poisson flow generative models

被引:0
|
作者
Hein, Dennis [1 ,2 ]
Holmin, Staffan [3 ,4 ]
Szczykutowicz, Timothy [5 ]
Maltz, Jonathan S. [6 ]
Danielsson, Mats [1 ,2 ]
Wang, Ge [7 ]
Persson, Mats [1 ,2 ]
机构
[1] KTH Royal Inst Technol, Dept Phys, S-1142 Stockholm, Sweden
[2] Karolinska Univ Hosp, MedTechLabs, S-17164 Stockholm, Sweden
[3] Karolinska Inst, Dept Clin Neurosci, S-17164 Stockholm, Sweden
[4] Karolinska Univ Hosp, Dept Neuroradiol, S-17164 Stockholm, Sweden
[5] Univ Wisconsin, Sch Med & Publ Hlth, Dept Radiol, Madison, WI 53705 USA
[6] GE HealthCare, Waukesha, WI 53188 USA
[7] Rensselaer Polytech Inst, Biomed Imaging Ctr, Ctr Biotechnol & Interdisciplinary Studies, Sch Engn,Dept Biomed Engn, Troy, NY 12180 USA
关键词
Deep learning; Photon-counting CT; Denoising; Diffusion models; Poisson flow generative models; NETWORK; REDUCTION;
D O I
10.1186/s42492-024-00175-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Deep learning (DL) has proven to be important for computed tomography (CT) image denoising. However, such models are usually trained under supervision, requiring paired data that may be difficult to obtain in practice. Diffusion models offer unsupervised means of solving a wide range of inverse problems via posterior sampling. In particular, using the estimated unconditional score function of the prior distribution, obtained via unsupervised learning, one can sample from the desired posterior via hijacking and regularization. However, due to the iterative solvers used, the number of function evaluations (NFE) required may be orders of magnitudes larger than for single-step samplers. In this paper, we present a novel image denoising technique for photon-counting CT by extending the unsupervised approach to inverse problem solving to the case of Poisson flow generative models (PFGM)++. By hijacking and regularizing the sampling process we obtain a single-step sampler, that is NFE = 1. Our proposed method incorporates posterior sampling using diffusion models as a special case. We demonstrate that the added robustness afforded by the PFGM++ framework yields significant performance gains. Our results indicate competitive performance compared to popular supervised, including state-of-the-art diffusion-style models with NFE = 1 (consistency models), unsupervised, and non-DL-based image denoising techniques, on clinical low-dose CT data and clinical images from a prototype photon-counting CT system developed by GE HealthCare.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Photon-Counting Computed Tomography Scan of a Cerebrospinal Fluid Venous Fistula
    Schwartz, Fides R.
    Malinzak, Michael D.
    Amrhein, Timothy J.
    JAMA NEUROLOGY, 2022, 79 (06) : 628 - 629
  • [32] STATISTICAL REFINEMENT OF TRANSMISSION COMPUTED TOMOGRAMS IN HIGH PHOTON-COUNTING NOISE
    SAUER, K
    LIU, B
    VISUAL COMMUNICATIONS AND IMAGE PROCESSING IV, PTS 1-3, 1989, 1199 : 944 - 951
  • [33] Novel photon-counting low-dose computed tomography using a multi-pixel photon counter
    Morita, H.
    Oshima, T.
    Kataoka, J.
    Arimoto, M.
    Nitta, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 58 - 65
  • [34] Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography
    Curtis, Tyler E.
    Roeder, Ryan K.
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (01)
  • [35] Proton stopping power ratio prediction using photon-counting computed tomography and deep learning
    Larsson, Karin
    Hein, Dennis
    Huang, Ruihan
    Collin, Daniel
    Andersson, Jonas
    Persson, Mats
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [36] Myocardial Late Iodine Enhancement Using Photon-Counting Computed Tomography in Patients With Hypertrophic Cardiomyopathy
    Nishihara, Takahiro
    Miyoshi, Toru
    Akagi, Noriaki
    Nakashima, Mitsutaka
    Nakamura, Kazufumi
    Ito, Hiroshi
    CIRCULATION REPORTS, 2023, 5 (06) : 269 - 270
  • [37] Spectral Photon-Counting Computed Tomography: A Review on Technical Principles and Clinical Applications
    Tortora, Mario
    Gemini, Laura
    D'Iglio, Imma
    Ugga, Lorenzo
    Spadarella, Gaia
    Cuocolo, Renato
    JOURNAL OF IMAGING, 2022, 8 (04)
  • [38] Development of a scanner-specific simulation framework for photon-counting computed tomography
    Abadi, Ehsan
    Harrawood, Brian
    Rajagopal, Jayasai R.
    Sharma, Shobhit
    Kapadia, Anuj
    Segars, William Paul
    Stierstorfer, Karl
    Sedlmair, Martin
    Jones, Elizabeth
    Samei, Ehsan
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [39] Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study
    Thomas Stein
    Jana Taron
    Niklas Verloh
    Michael Doppler
    Alexander Rau
    Muhammad Taha Hagar
    Sebastian Faby
    Dimos Baltas
    Dirk Westermann
    Isabelle Ayx
    Stefan O. Schönberg
    Konstantin Nikolaou
    Christopher L. Schlett
    Fabian Bamberg
    Jakob Weiss
    Scientific Reports, 13
  • [40] Photon-counting computed tomography thermometry via material decomposition and machine learning
    Nathan Wang
    Mengzhou Li
    Petteri Haverinen
    Visual Computing for Industry, Biomedicine, and Art, 6