CRRT circuit venous air chamber design and intra-chamber flow dynamics: a computational fluid dynamics study

被引:0
|
作者
Shimizu, Kota [1 ]
Yamada, Toru [2 ]
Moriyama, Kazuhiro [3 ]
Kato, China [2 ]
Kuriyama, Naohide [4 ]
Hara, Yoshitaka [4 ]
Kawaji, Takahiro [4 ]
Komatsu, Satoshi [4 ]
Morinishi, Yohei [2 ]
Nishida, Osamu [4 ]
Nakamura, Tomoyuki [4 ]
机构
[1] Fujita Hlth Univ Hosp, Dept Radiol, Toyoake, Aichi, Japan
[2] Nagoya Inst Technol, Grad Sch Engn, Nagoya, Aichi, Japan
[3] Fujita Hlth Univ, Sch Med, Lab Immune Response & Regulatory Med, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi 4701192, Japan
[4] Fujita Hlth Univ, Sch Med, Dept Anesthesiol & Crit Care Med, Toyoake, Aichi, Japan
关键词
Computational fluid dynamics; Computational fluid dynamics analysis; Continuous renal replacement therapy; Grid diagram; Horizontal inflow chamber; Streamlines of the flow field; Velocity contours of the flow field; Venous air trap chamber; Vertical inflow chamber; Working fluid; BLOOD; VISCOSITY; IMPACT;
D O I
10.1186/s41100-024-00569-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
BackgroundVenous air trap chamber designs vary considerably to suit specific continuous renal replacement therapy circuits, with key variables including inflow design and filter presence. Nevertheless, intrachamber flow irregularities do occur and can promote blood coagulation. Therefore, this study employed computational fluid dynamics (CFD) simulations to better understand how venous air trap chamber designs affect flow.MethodsThe flow within a venous air trap chamber was analyzed through numerical calculations based on CFD, utilizing large eddy simulation. The working fluid was a 33% glycerin solution, and the flow rate was set at 150 ml/min. A model of a venous air trap chamber with a volume of 15 ml served as the computational domain. Calculations were performed for four conditions: horizontal inflow with and without a filter, and vertical inflow with and without a filter. Streamline plots and velocity contour plots were generated to visualize the flow.ResultsIn the horizontal inflow chamber, irrespective of filter presence, ultimately the working fluid exhibited a downstream vortex flow along the chamber walls, dissipating as it progressed, and being faster near the walls than in the chamber center. In the presence of a filter, the working fluid flowed uniformly toward the outlet, while in the absence of a filter the flow became turbulent before reaching the outlet. These observations indicate a streamlining effect of the filter.In the vertical inflow chamber, irrespective of filter presence, the working fluid flowed vertically from the inlet into the main flow direction. Part of the working fluid bounced back at the chamber bottom, underwent upward and downward movements, and eventually flowed out through the outlet. Stagnation was observed at the top of the chamber. Without a filter, more working fluid bounced back from the bottom of the chamber.ResultsIn the horizontal inflow chamber, irrespective of filter presence, ultimately the working fluid exhibited a downstream vortex flow along the chamber walls, dissipating as it progressed, and being faster near the walls than in the chamber center. In the presence of a filter, the working fluid flowed uniformly toward the outlet, while in the absence of a filter the flow became turbulent before reaching the outlet. These observations indicate a streamlining effect of the filter.In the vertical inflow chamber, irrespective of filter presence, the working fluid flowed vertically from the inlet into the main flow direction. Part of the working fluid bounced back at the chamber bottom, underwent upward and downward movements, and eventually flowed out through the outlet. Stagnation was observed at the top of the chamber. Without a filter, more working fluid bounced back from the bottom of the chamber.ConclusionsCFD analysis estimated that the flow in a venous air trap chamber is affected by inflow method and filter presence. The "horizontal inflow chamber with filter" was identified as the design creating a smooth and uninterrupted flow throughout the chamber.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A computational fluid dynamics study of the effects of buoyancy on air flow surrounding a building
    Yau, Y. H.
    Lian, Y. C.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (03): : 257 - 271
  • [22] Study of Ammonia Concentration Characteristics and Optimization in Broiler Chamber during Winter Based on Computational Fluid Dynamics
    Zou, Xiuguo
    Wang, Siyu
    Qian, Yan
    Gong, Fei
    Zhang, Shixiu
    Hu, Jiangxue
    Liu, Wenchao
    Song, Yuanyuan
    Zhang, Shikai
    Meng, Jiawei
    Qiu, Xinfa
    AGRICULTURE-BASEL, 2022, 12 (02):
  • [23] Use of Computational Fluid Dynamics to Study Ammonia Concentrations at Pedestrian Height in Smart Broiler Chamber Clusters
    Li, Mengxi
    Zou, Xiuguo
    Feng, Bo
    Qiu, Xinfa
    AGRICULTURE-BASEL, 2023, 13 (03):
  • [24] The LDA study of flow gas-dynamics in a vortex chamber
    Volchkov, EP
    Lebedev, VP
    Lukashov, VV
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (01) : 35 - 42
  • [25] Numerical Research of Intra-Chamber Transient Processes Dynamics during Starting Operation of the Solid Propellant Rocket Engine with Special Arrangement
    Egorov M.Y.
    Russian Aeronautics, 2019, 62 (02): : 234 - 243
  • [26] Mathematical modeling and simulation of bacterial distribution in an aerobiology chamber using computational fluid dynamics
    Zargar, Bahram
    Kashkooli, Farshad M.
    Soltani, M.
    Wright, Kathryn E.
    Ijaz, M. Khalid
    Sattar, Syed A.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2016, 44 (09) : S127 - S137
  • [27] Optimization of 450mm Wafer Ashing Chamber by Computational Fluid Dynamics Simulation
    Cha, Young-Hwan
    Kim, Myoung-Soo
    Lee, Da-Hyeouk
    Kim, Ki-Bo
    Yang, Seung-Kook
    Park, Se-Geun
    RESEARCH IN MATERIALS AND MANUFACTURING TECHNOLOGIES, PTS 1-3, 2014, 835-836 : 1544 - +
  • [28] Computational Fluid Dynamics and Data-Based Mechanistic Modelling of a Forced Ventilation Chamber
    Tate, O.
    Wilson, E. D.
    Cheneler, D.
    Taylor, C. J.
    IFAC PAPERSONLINE, 2018, 51 (15): : 263 - 268
  • [29] Development of a thoron calibration chamber based on computational fluid dynamics simulation and validation with measurements
    Adelikhah, Mohammademad
    Imani, Morteza
    Kovacs, Tibor
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] Development of a thoron calibration chamber based on computational fluid dynamics simulation and validation with measurements
    Mohammademad Adelikhah
    Morteza Imani
    Tibor Kovács
    Scientific Reports, 13