Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

被引:0
|
作者
Zhu, Xiaoxian [1 ]
Peng, Qingjun [2 ]
Zou, Dexu [3 ]
Wang, Shan [2 ]
Wang, Haozhou [4 ]
Zhou, Fangrong [2 ]
Chu, Desheng [2 ,5 ]
机构
[1] China Southern Power Grid Yunnan Power Grid Co Ltd, Chuxiong Power Supply Bur, Chuxiong, Yunnan, Peoples R China
[2] Yunnan Power Grid Co Ltd, Elect Power Res Inst, Kunming, Yunnan, Peoples R China
[3] State Key Lab Power Transmiss Equipment Technol, Chongqing, Peoples R China
[4] Kunming Power Supply Bur Yunnan Power Grid Corp, Kunming, Yunnan, Peoples R China
[5] Beijing Univ Aeronaut & Astronaut, Sch Automat Sci & Elect Engn, Beijing, Peoples R China
关键词
harmonic analysis; synchronisation; transformers; DISTRIBUTION-SYSTEMS; IDENTIFICATION; ERRORS;
D O I
10.1049/elp2.12481
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti-interference, and adaptability, and can provide basic information for harmonic localisation and traceability. The authors focus on the problem wherein the accuracy of harmonic state estimation is affected by the current CVT-based synchronous voltage phase measurement error. Furthermore, it proposes a harmonic voltage phase reconstruction and harmonic state estimation method based on CVT measurement data by considering the CVT wideband transfer characteristics from the voltage phase perspective. image
引用
收藏
页码:1332 / 1346
页数:15
相关论文
共 50 条
  • [21] EQUIVALENT-CIRCUIT MODELING OF A CAPACITIVE VOLTAGE TRANSFORMER FOR POWER-SYSTEM HARMONIC FREQUENCIES
    VERMEULEN, HJ
    DANN, LR
    VANROOIJEN, J
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (04) : 1743 - 1749
  • [22] Power Flow Estimation based on Power Transformer Plate Data and Voltage Measurement
    Passos, Frederico Oliveira
    de Carvalho Filho, Jose Maria
    [J]. 2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 352 - 356
  • [23] Research on electronic voltage transformer based on capacitive voltage divider
    Luo, Sunan
    Nan, Zhenle
    [J]. Gaodianya Jishu/High Voltage Engineering, 2004, 30 (10):
  • [24] Influences of circuit parameters of capacitor voltage transformer on grid harmonic voltage measurements
    [J]. Feng, Yu, 1600, Chinese Society for Electrical Engineering (34):
  • [25] Research on Harmonic Transmission Characteristics of Capacitor Voltage Transformer
    Wei, Chaofeng
    Li, Qionglin
    Jiang, Jiandong
    [J]. 2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2017, : 2564 - 2570
  • [26] A shunt active harmonic filter based on a voltage detection method for harmonic voltage control
    Yuan, ZH
    Du, Y
    [J]. PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 763 - 768
  • [27] A harmonic voltage measurement method based on CVT capacitor current
    Dai S.
    Liu S.
    Zhao Q.
    Li Q.
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (20): : 141 - 147
  • [28] Harmonic State Estimation for Distribution Networks Based on Multi-Measurement Data
    Wang, Ying
    Ma, Haixing
    Xiao, Xianyong
    Wang, Yang
    Zhang, Yan
    Wang, Huajia
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2311 - 2325
  • [29] Errors of Capacitive-Voltage-Transformers Used for Harmonic Measurements
    Brehm, M.
    Aristoy, G.
    Trigo, L.
    Santos, A.
    Slomovitz, D.
    [J]. 2017 IEEE URUCON, 2017,
  • [30] Harmonic and Interharmonic Phasor Estimation Using Matrix Pencil Method for Phasor Measurement Units
    Bernard, Lakshan
    Goondram, Sunny
    Bahrani, Behrooz
    Pantelous, Athanasios A.
    Razzaghi, Reza
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (02) : 945 - 954